Responses of the AC and DC global electric circuits (GECs) to the large eruption of the Hunga Tonga‐Hunga Ha'apai (HT‐HH) volcano on 15 January 2022 are discussed. The AC‐related investigation is based on Schumann resonance (SR) measurements from six stations on four continents. The DC‐related investigation utilizes atmospheric electric field (potential gradient, PG) measurements from six recording stations in Europe and the USA. According to data from the GLD360 and WWLLN lightning detection networks, the peak lightning stroke rate, 83/s, was dominated by negative polarity lightning, but the distributions of positive and negative lightning discharges in latitude and longitude around the volcano differed. A global intensification of SR is apparent in connection with the enhanced lightning activity caused by the eruption. SR data‐based results confirm that the lightning activity in the eruption dominated the naturally occurring global activity for a period of about 1 hr. The highly localized increase in lightning activity over HT‐HH was a unique point source of SR excitation. PG measurements suggest that impulse‐like charging of the DC GEC, by ∼15%, via negative cloud‐to‐ground lightning strokes took place twice during the eruption. A time constant of 7 or 8 min has been inferred for near‐surface PG changes due to these enhancements. This could be the first direct measurement of the time constant of the GEC near the Earth's surface, as well as the first observation of the direct charging of the DC GEC by a unique atmospheric electrified source.
8 April 2020 in History of Geo- and Space Sciences
The Széchenyi István Geophysical Observatory, also known as the Nagycenk Geophysical Observatory (NCK), was established in 1957. It has been the only measurement site in Hungary where observations of various parameters of the atmospheric global electric circuit are made in the framework of organized research under the umbrella of the Hungarian Academy of Sciences (MTA). Measurements of the atmospheric electrical potential gradient (PG) and Schumann resonances (SRs) running quasi-continuously in the observatory for decades provide an invaluable source of information for geophysical research. This paper gives an overview on the history of the observatory and particularly on various atmospheric electricity (AE) measurements on-site to commemorate the efforts and excellence of the people who served atmospheric sciences by dedicating their lives to obtaining high-quality, reliable data and scientific achievements at the highest possible level.
1 January 2018 in International Journal of Global Warming
In order to satisfy the continuous urging demands for updated and relevant information from various impact researchers, end-users, and decision makers, the RegCM4.3 model is used taking into account the new RCP4.5 and RCP8.5 radiative forcing scenarios to provide climate projection for Hungary with 10 km horizontal resolution. Overall, the results suggest significant warming in Hungary. The greatest temperature increase is likely to occur in summer, which is why the projected changes in warm extremes are also analysed in this study.
Observed responses of the AC and DC parts of the Global Electric Circuit (GEC) to the large eruption of the Hunga Tonga - Hunga Ha’apai (HT-HH) volcano on 15 January, 2022 are presented. The AC-related investigation is based on Schumann resonance (SR) measurements from the Nagycenk Geophysical Observatory (NCK), Hungary as well as from distant stations on the globe belonging to the HeartMath Institute (https://www.heartmath.org/gci/). The DC-related investigation is based on atmospheric electric potential gradient measurements (PG) from six recording stations in Europe and in the USA. The GLD360 and the WWLLN lightning detection networks were used to characterize lightning activity in the vicinity of the HT-HH island on the investigated day. The peak lightning stroke rate reached 80/s (5000/minute), whereas the average global rate is ~44/s. Lightning discharges occurred in rings around the vent of the volcano. Peak currents and the diameter of the ring of positive and negative polarity lightning strokes varied differently in the main phase of the eruption. At its peak, negative lightning dominated the electric activity in the volcanic cloud.A global intensification of SR is apparent in connection with the enhanced lightning activity caused by the eruption. The SR data together with the global network observations indicate that the lightning activity in the eruption dominates the naturally occurring global activity for a period of at least one hour. The highly localized increase in lightning activity over HT-HH provides a unique point source of excitation for the SR.In contrast with the dramatic response of the AC global circuit, the response of the DC GEC to this exceptional eruption is not readily unambiguous in the PG measurements. The observations suggest that impulse-like charging of the GEC by ~15% via -CG lightning strokes took place two times during the eruption. A time constant of 7 or 8 minutes has been inferred for near-surface electric field changes from these enhancements. This could be the first direct measurement of the time constant of the GEC near the Earth’s surface, as well as the first observation of the direct charging of the DC GEC by a single atmospheric electrified source.