19 August 2019 in IEEE Transactions on Power Delivery
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB) are implemented to interrupt the DC fault current. Subsequent to fault isolation, the DCCBs are required to automatically re-close to restore power transmission quickly. However, when the DCCBs are re-closed to permanent faults, they will be tripped again, resulting in a high requirement of interruption capacity for DCCBs and second overcurrent strikes on the HVDC systems. To overcome the drawbacks of the conventional auto-reclosing scheme, this paper proposes an adaptive reclosing scheme based on the active pulse injection from the converter associated with the coordination control of hybrid DCCBs. The single-end adaptive reclosing scheme as well as two ends adaptive reclosing scheme dedicated to two-terminal HVDC systems and meshed DC grids are presented respectively. By applying this method, the location of faults can also be achieved in the case of permanent faults. In order to verify the effectiveness of the proposed adaptive reclosing schemes, extensive simulations have been conducted under PSCAD/EMTDC.
2 October 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
To detect the DC faults for MMC based DC grids using overhead line transmission, many protection methods in phase-domain have been proposed. These existing protection methods suffer from incomplete function, weak theoretical basis and sensitivity to fault resistance and noise disturbance. To overcome these shortcomings, this paper proposes an improved DC fault protection algorithm using the modal-domain approach for the MMC based overhead DC grids, which decouples interaction between positive and negative poles and mitigates the strong frequency-dependency of the characteristic impedance in phase-domain. The DC fault equivalent circuits are established in modal-domain and the fault characteristics during the initial stage are analysed. Based on the modal-domain analysis, the line-mode reactor voltage which combines fault characteristics of negative and positive reactor voltages, is employed to identify the internal faults. The zero-mode reactor voltage which enlarges the differences between faulty and healthy poles, is employed to select the faulted pole. This method is robust to fault resistance and noise with high detection speed. In addition, it is not affected by power reversal, AC faults and DCCB operation, which are validated and evaluated by simulations in PSCAD/EMTDC.
1 October 2018 in International Journal of Electrical Power & Energy Systems
21 September 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The wide-band oscillation of the hybrid MMC induced by excessive power infeed under weak AC power system integration is analyzed in this paper. A closed-loop state-space-based time-domain small-signal model is firstly established to investigate the instability problem. Different from the findings in two-level VSCs or half-bridge MMCs, the root locus analysis and participation factor analysis in this paper reveals that the oscillation frequency and involved control loops are highly related to the operation status. When hybrid MMC operates as a rectifier, a low-frequency oscillation is observed with the d-channel control loop mainly participated. In contrast, a high-frequency oscillation occurs with a q-channel control loop mainly involved when the hybrid MMC operates as an inverter. This wide-band oscillation phenomenon is explored with the aid of two simplified loop-gain-based s-domain models, which are derived referring to the selective modal analysis approach. To suppress the oscillation, sensitivity analysis regarding the impact of parameters on the phase margin is conducted to recognize effective parameter adjustment methods. The analysis results are validated by detailed electromagnetic simulations.
16 April 2021 in IEEE Transactions on Power Delivery
The cascaded hybrid LCC-MMC inverter is considered as a feasible option to mitigate the commutation failure problem of conventional LCC-HVDC while maintaining bulk power transmission capability. However, the coupling between different types of converters may result in instability when the inverter integrates with weak AC systems. This paper establishes a small-signal model of the cascaded LCC-MMC inverter based hybrid HVDC system and validates the model against PSCAD/EMTDC. Through eigenvalue analysis, the impact of the strength and proximity of receiving AC systems on the small-signal stability is investigated, and the stable zone of the strength of receiving AC systems is identified. Besides, a supplementary coupling mitigation control is proposed to tackle the instability problem under weak AC systems integration. Both analytical results and time-domain simulations demonstrate the validity of the supplementary control.
15 September 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Voltage source converters (VSCs) with self-commutation ability are suitable to interconnect weak AC systems. This paper conducts a comparative study of the small-signal stability characteristics for three typical VSCs, namely, the two-level VSCs (TL-VSCs), the half-bridge modular multilevel converters (HB-MMCs) and the hybrid MMCs (HY-MMCs), under weak AC system integration with special consideration on both inverter and rectifier operation. The frequency responses based on impedance models are compared using the frequency-domain analysis. The oscillation frequencies and mainly participated state variables of the unstable modes are compared using root locus and participation factor analysis in time-domain. Proper parameter retuning approaches for stability enhancement are proposed. The above analysis is adequately validated by electromagnetic simulations.