False-positives plague high-throughput screening in general and are costly as they consume resource and time to resolve. Methods that can rapidly identify such compounds at the initial screen are therefore of great value. Advances in mass spectrometry have led to the ability to screen inhibitors in drug discovery applications by direct detection of an enzyme reaction product. The technique is free from some of the artefacts that trouble classical assays such as fluorescence interference. Its direct nature negates the need for coupling enzymes and hence is simpler with fewer opportunities for artefacts. Despite its myriad advantages, we report here a mechanism for false-positive hits which has not been reported in the literature. Further we have developed a pipeline for detecting these false-positive hits and suggest a method to mitigate against them.
The maturation of the RNA cap involving guanosine N-7 methylation, catalyzed by the HsRNMT (RNA guanine-7 methyltransferase)-RAM (RNA guanine-N7 methyltransferase activating subunit) complex, is currently under investigation as a novel strategy to combat PIK3CA mutant breast cancer. However, the development of effective drugs is hindered by a limited understanding of the enzyme’s mechanism and a lack of small molecule inhibitors. Following the elucidation of the Hs RNMT-RAM molecular mechanism, we report the biophysical characterization of two small molecule hits. Biophysics, biochemistry and structural biology confirm that both compounds bind competitively with cap and bind effectively to Hs RNMT-RAM in the presence of the co-product SAM, with a binding affinity (K D ) of approximately 1 μM. This stabilisation of the enzyme-product complex results in uncompetitive inhibition. Finally, we describe the properties of the cap pocket and provided suggestions for further development of the tool compounds.
False-positives plague High Throughput Screening in general and are costly as they consume resource and time to resolve. Methods that can rapidly identify such compounds at the initial screen are therefore of great value. Advances in mass spectrometry have led to the ability to screen inhibitors in drug discovery applications by direct detection of an enzyme reaction product. The technique is free from some of the artefacts that trouble classical assays such as fluorescence interference. Its direct nature negates the need for coupling enzymes and hence is simpler with fewer opportunities for artefacts. Despite its myriad advantages, we report here a mechanism for false-positive hits which has not been reported in the literature. Further we have developed a pipeline for detecting these false-positive hits and suggest a method to mitigate against them. Graphical