Dennis J. Paustenbach

Dennis J. Paustenbach

Auto-generated profile, based on publicly available information

Dennis J. Paustenbach

Cardno ChemRisk, Jackson, WY 83001, USA

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2017 in Critical Reviews in Toxicology
Verified
Journal Article
Closed access
SGSherilyn A. Gross
Sherilyn A. Gross
DPDennis J. Paustenbach
Dennis J. Paustenbach
The Shanghai Health Study (SHS) was a large epidemiology study conducted as a joint effort between the University of Colorado and Fudan University in Shanghai, China. The study was funded by members of the American Petroleum Institute between 2001 and 2009 and was designed to evaluate the human health effects associated with benzene exposure. Two arms of the SHS included: an occupational-based molecular epidemiology study and several hospital-based case control studies. Consistent with historical literature, following sufficient exposure to relatively high airborne concentrations and years of exposure, the SHS concluded that exposure to benzene resulted in an increased risk of various blood and bone marrow abnormalities such as benzene poisoning, aplastic anemia (AA), myelodysplastic syndrome (MDS), and acute myeloid leukemia (AML). Non-Hodgkin lymphoma (NHL) was not significantly increased for the exposures examined in this study. Perhaps the most important contribution of the SHS was furthering our understanding of the mechanism of benzene-induced bone marrow toxicity and the importance of identifying the proper subset of MDS relevant to benzene. Investigators found that benzene-exposed workers exhibited bone marrow morphology consistent with an immune-mediated inflammatory response. Contrary to historic reports, no consistent pattern of cytogenetic abnormalities was identified in these workers. Taken together, findings from SHS provided evidence that the mechanism for benzene-induced bone marrow damage was not initiated by chromosome abnormalities. Instead, chronic inflammation, followed by an immune-mediated response, is likely to play a more significant role in benzene-induced disease initiation and progression than previously thought.

26 November 2018 in Critical Reviews in Toxicology
Verified
Journal Article
Closed access
MKMichael Kovochich
Michael Kovochich
BFBrent L. Finley
Brent L. Finley
RNRachel Novick
Rachel Novick
AMAndrew D. Monnot
Andrew D. Monnot
EDEllen Donovan
Ellen Donovan
DPDennis J. Paustenbach
Dennis J. Paustenbach
Hip implants have improved the mobility and quality of life in millions of individuals. This review presents the evolution of scientific knowledge regarding the history and understanding of systemic and local metal toxicological concerns of hip implants designs utilizing metal-on-metal (MoM) bearing surfaces used in hip resurfacing arthroplasty (HRA) and total hip arthroplasty (THA). This analysis addresses: (1) the history of the development of MoM hip implants; (2) the clinical and toxicological rationale for introducing second-generation MoM implants in the early 2000s as an alternative to metal-on-polyethylene bearings; (3) the subsequent history regarding success and failure of second-generation MoM devices; (4) a detailed review of the history of MoM toxicology, including carcinogenic potential, metal blood levels, hypersensitivity, and release of wear particles; and (5) a review of local tissue effects and MoM patient management. We have included an analysis of MoM THA and HRA survivorship trends aggregated from over 200 studies. By around 2008, HRA continued to be a challenging procedure with variable success rates, and concurrently, some THA devices began to experience higher than expected revision rates based on annual registry reports. The unexpected THA outcomes and continued challenges with HRA devices prompted many surgeons to question the role of toxicological effects in device performance. Regarding hypersensitivity, while conversion to metal sensitized status in some MoM patients occurs based on the skin patch or lymphocyte transformation testing, there is no evidence of a causal relationship between positive test results and device failure. The weight of evidence indicates that nanoparticles released from MoM implants are cleared from the local synovial space under normal wear conditions. The available data indicate that there are no discernible increases in local or systemic tumors following CoCr alloy implantation. Systemic health effects are rarely reported in MoM implant patients and are unlikely when blood concentrations are below 300 µg/L except when patients have specific risk factors. Over time, patient management evolved to include assays aimed at predicting implant function (blood monitoring) and soft tissue reactions (MRI and ultrasound imaging). Validation of these biomarkers as a diagnostic tool for implant function, patient pain, and, ultimately, implant survival, remains lacking. After the introduction of these biomarkers, differences in implant revision decisions emerged based on imaging abnormalities, increased serum metal ion levels, and overall clinical presentation. Discrepancies in patient management algorithms and the lack of consensus in local biological effects terminology have contributed to variability in reporting incidence, etiology, and dose effects on local tissue responses in MoM implants. This variability has contributed to a debate regarding the benefit or risk of revising asymptomatic patients. Therefore, while toxicological assessments of normal functioning MoM implants indicate that MoM implants are relatively safe because of low wear and clearance of metal, more analysis of revision data is needed in order to best inform patient management decisions, particularly for asymptomatic patients, as well as patients with minor symptoms under consideration for conservative pain management treatments.

22 March 2017 in Critical Reviews in Toxicology
Verified
Journal Article
Closed access
CBChristy A. Barlow
Christy A. Barlow
JSJennifer Sahmel
Jennifer Sahmel
DPDennis J. Paustenbach
Dennis J. Paustenbach
JHJohn L. Henshaw
John L. Henshaw
The understanding by industrial hygienists of the hazards of asbestos and appropriate ways to characterize and control exposure has evolved over the years. Here, a detailed analysis of the evolution of industrial hygiene practices regarding asbestos and its health risks, from the early 1900s until the advent of the national occupational health and safety regulatory structure currently in place in the US (early-to-mid 1970s) is presented. While industrial hygienists recognized in the early 1900s that chronic and high-level exposures to airborne concentrations of asbestos could pose a serious health hazard, it was not until the mid-1950s that the carcinogenic nature of asbestos began to be characterized and widespread concern followed. With the introduction of the membrane filter sampling method in the late 1960s and early 1970s, asbestos sampling and exposure assessment capabilities advanced to a degree which allowed industrial hygienists to more precisely characterize the exposure–response relationship. The ability of industrial hygienists, analytical chemists, toxicologists, and physicians to more accurately define this relationship was instrumental to the scientific community’s ability to establish Occupational Exposure Levels (OELs) for asbestos. These early developments set the stage for decades of additional study on asbestos exposure potential and risk of disease. This was followed by the application of engineering controls and improved respiratory protection which, over the years, saved thousands of lives. This paper represents a state-of-the-art review of the knowledge of asbestos within the industrial hygiene community from about 1900 to 1975.

6 December 2017 in Inhalation Toxicology
Verified
Journal Article
Closed access
AAAnders Abelmann
Anders Abelmann
JMJoshua R. Maskrey
Joshua R. Maskrey
JLJason T. Lotter
Jason T. Lotter
ACAaron M. Chapman
Aaron M. Chapman
MNMelanie D. Nembhard
Melanie D. Nembhard
DPDennis J. Paustenbach
Dennis J. Paustenbach
Although industrial uses of asbestos have declined since the 1970s, in recent years there has been a renewed interest in para-occupational (“take-home”) exposure to these fibers. The aim of this study was to quantify the release of asbestos fibers, if any, during the shaking out of crocidolite- and chrysotile-contaminated clothing in a simulated at-home setting. An exposure study was conducted in which personal and area air samples were collected during the handling (i.e. shake-out) of work clothing (shirt and pants) previously worn by an operator who had cut asbestos-containing cement pipe. During eight “loading” events, the operator cut a historically representative asbestos-containing cement pipe (10% crocidolite and 25% chrysotile) using a powered abrasive saw. Subsequently, 30-minute air samples were collected during four “shake-out” events, each of which consisted of the handling of two complete sets of contaminated work clothes. Samples were analyzed in accordance with NIOSH methods 7400 and 7402. The mean phase contrast microscopy equivalent (PCME) airborne concentrations were 0.52 f/cc (SD = 0.34 f/cc) for total asbestos fibers, 0.36 f/cc (SD = 0.26 f/cc) for chrysotile and 0.17 f/cc (SD = 0.096 f/cc) for crocidolite. Based on likely estimates of the frequency of laundering activities, and assuming that the dusty clothing (1) is not blown off in the occupational setting using compressed air and (2) is not shaken out before entering the home, a family member handling the clothing could potentially have a lifetime cumulative exposure to chrysotile and crocidolite of approximately 0.20 f/cc-year and 0.096 f/cc-year, respectively.

1 March 2010 in Chemico-Biological Interactions
Verified
Journal Article
Closed access
JKJ.J. Keenan
J.J. Keenan
SGS.H. Gaffney
S.H. Gaffney
DGD.A. Galbraith
D.A. Galbraith
PBP. Beatty
P. Beatty
DPD.J. Paustenbach
D.J. Paustenbach

15 September 2016 in BMC Public Health
Verified
Journal Article
Open access
PDF file
BKBrent D. Kerger
Brent D. Kerger
ABAutumn Bernal
Autumn Bernal
DPDennis J. Paustenbach
Dennis J. Paustenbach
GHGavin Huntley-Fenner
Gavin Huntley-Fenner
Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1) intrauterine contraceptive devices (IUDs); 2) silicone gel-filled breast implants (SGBI); 3) metal-on-metal hip implants (MoM); and 4) the drug Tysabri. Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may exhibit widespread use and good safety records in other countries. We conclude that the ‘negative halo effect’ associated with a stigma, rather than an objective risk-benefit assessment of medical products can increase negative health outcomes for patients due to reduced or inappropriate product usage.