Rahul Alapati

Rahul Alapati

Auto-generated profile, based on publicly available information

Rahul Alapati

Department of Otolaryngology‐Head and Neck Surgery The University of Kansas Medical Center Kansas City Kansas USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in Thyroid®
Verified
Journal Article
Closed access
DCDaniel J. Campbell
Daniel J. Campbell
LELeonard E. Estephan
Leonard E. Estephan
ESElliott Sina
Elliott Sina
EMEric V. Mastrolonardo
Eric V. Mastrolonardo
RARahul Alapati
Rahul Alapati
ECElizabeth E. Cottrill
Elizabeth E. Cottrill
Background: ChatGPT, an artificial intelligence (AI) chatbot, is the fastest growing consumer application in history. Given recent trends identifying increasing patient use of Internet sources for self-education, we seek to evaluate the quality of ChatGPT-generated responses for patient education on thyroid nodules. Methods: ChatGPT was queried 4 times with 30 identical questions. Queries differed by initial chatbot prompting: no prompting, patient-friendly prompting, 8th-grade level prompting, and prompting for references. Answers were scored on a hierarchical score: incorrect, partially correct, correct, or correct with references. Proportions of responses at incremental score thresholds were compared by prompt type using chi-squared analysis. Flesch–Kincaid grade level was calculated for each answer. The relationship between prompt type and grade level was assessed using analysis of variance. References provided within ChatGPT answers were totaled and analyzed for veracity. Results: Across all prompts ( n = 120 questions), 83 answers (69.2%) were at least correct. Proportions of responses that were at least partially correct ( p = 0.795) and correct ( p = 0.402) did not differ by prompt; responses that were correct with references did ( p < 0.0001). Responses from 8th-grade level prompting were the lowest mean grade level (13.43 ± 2.86) and were significantly lower than no prompting (14.97 ± 2.01, p = 0.01) and prompting for references (16.43 ± 2.05, p < 0.0001). Prompting for references generated 80/80 (100%) of referenced medical publications within answers. Seventy references (87.5%) were legitimate citations, and 58/80 (72.5%) provided accurately reported information from the referenced publication. Conclusion: ChatGPT overall provides appropriate answers to most questions on thyroid nodules regardless of prompting. Despite targeted prompting strategies, ChatGPT reliably generates responses corresponding to grade levels well-above accepted recommendations for presenting medical information to patients. Significant rates of AI hallucination may preclude clinicians from recommending the current version of ChatGPT as an educational tool for patients at this time.

7 December 2023 in American Journal of Otolaryngology
Verified
Journal Article
Open access
RARahul Alapati
Rahul Alapati
SWSarah F. Wagoner
Sarah F. Wagoner
ANAntonio Bon Nieves
Antonio Bon Nieves
ALAmelia Lawrence
Amelia Lawrence
DRDavid Rouse
David Rouse
CLChristopher Larsen
Christopher Larsen
To identify and report a single center experience with upper airway stimulator device-related failures. Retrospective case series. Single tertiary academic center. Retrospective data on 352 patients who underwent UAS surgery with an Inspire device from 2016 to 2023 was collected, including demographics, comorbidities, and nature of device failure requiring revision surgery. Out of the 348 patients included in our analysis, 16 (4.6 %) required revision due to device failure, with an average interval of 772 days (∼2 years) between initial implant and revision. Most failures were attributed to respiratory sensing lead damage (n = 11, 68.8 %), resulting in high system impedance and subsequent device malfunction. Lead fracture causes varied, including idiopathic occurrences and potential trauma. Lead migration was noted in one case (6.3 %), where the hypoglossal electrode detached from the nerve. Two patients (12.3 %) required implantable pulse generator (IPG) replacement, one after experiencing trauma and the other due to unclear source of malfunction. One patient (6.3 %) required complete system replacement following high lead impedance and absent tongue motion. The last patient required replacement of both the IPG and respiratory lead after experiencing high lead impedance (6.3 %). Respiratory sensing lead fracture emerged as the leading cause of device failure in this cohort, underscoring the need to address this under-reported issue, potentially linked to the time lapse after device implantation.

27 June 2024 in The Laryngoscope
Verified
Journal Article
Closed access
RARahul Alapati
Rahul Alapati
BRBryan Renslo
Bryan Renslo
LJLaura Jackson
Laura Jackson
HMHanna Moradi
Hanna Moradi
JOJamie R. Oliver
Jamie R. Oliver
ABAndrés M. Bur
Andrés M. Bur

11 September 2024 in The Laryngoscope
Verified
Journal Article
Closed access
RARahul Alapati
Rahul Alapati
BRBryan Renslo
Bryan Renslo
SWSarah F. Wagoner
Sarah F. Wagoner
OKOmar Karadaghy
Omar Karadaghy
ASAisha Serpedin
Aisha Serpedin
ABAndrés M. Bur
Andrés M. Bur

22 April 2024 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
RARahul Alapati
Rahul Alapati
ANAntonio Bon Nieves
Antonio Bon Nieves
SWSarah Wagoner
Sarah Wagoner
ALAmelia Lawrence
Amelia Lawrence
JJJill Jones
Jill Jones
ABAndrés M. Bur
Andrés M. Bur
Objectives: To provide a comprehensive summary of the different modalities available to measure soft tissue fibrosis after radiotherapy in head and neck cancer patients.Data Sources: PubMed, Scopus, and Web of Sciences.Review Methods: A search was conducted using a list of medical subject headings and terms related to head and neck oncology, radiation fibrosis, and quantitative measurements, including bioimpedance, MRI, and ultrasound. Original research related to quantitative measurement of neck fibrosis post‐radiotherapy was included without time constraints, while reviews, case reports, non‐English texts, and inaccessible studies were excluded. Discrepancies during the review were resolved by discussing with the senior author until consensus was reached.Results: A total of 284 articles were identified and underwent title and abstract screening. Seventeen articles had met our criteria for full‐text review based on relevance, of which nine had met our inclusion criteria. Young's modulus (YM) and viscoelasticity measures have demonstrated efficacy in quantifying neck fibrosis, with fibrotic tissues displaying significantly higher YM values and altered viscoelastic properties such as increased stiffness rate‐sensitivity and prolonged stress‐relaxation post‐radiation. Intravoxel incoherent motion offers detailed insights into tissue changes by assessing the diffusion of water molecules and blood perfusion, thereby differentiating fibrosed from healthy tissues. Shear wave elastography has proven to be an effective technique for quantifying radiation‐induced fibrosis in the head and neck region by measuring shear wave velocity.Conclusion: There are various modalities to measure radiation‐induced fibrosis, each with its unique strengths and limitations. Providers should be aware of these implications and decide on methodologies based on their specific clinical workflow.Level of Evidence: Step 5.

4 March 2024 in The Laryngoscope
Verified
Journal Article
Closed access
RARahul Alapati
Rahul Alapati
SWSarah F. Wagoner
Sarah F. Wagoner
ALAmelia Lawrence
Amelia Lawrence
ANAntonio Bon Nieves
Antonio Bon Nieves
ADAtharva Desai
Atharva Desai
ABAndrés M. Bur
Andrés M. Bur