We present a method for measuring branching fractions for the decay of atomic energy levels to lower-lying states based on time-resolved recording of the atom’s fluorescence during a series of population transfers. We apply this method to measure the branching fractions for the decay of the state of to the and states to be 0.935 65(7) and 0.064 35(7), respectively. The measurement scheme requires that at least one of the lower-lying states be long lived. The method is insensitive to fluctuations in laser light intensity and magnetic field and is readily applicable to various atomic species due to its simplicity. Our result distinguishes well among existing state-of-the-art theoretical models of .
1 November 2015 in Review of Scientific Instruments
We present a compact field-programmable gate array (FPGA) based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 transistor-transistor logic (TTL) channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube. There are 16 independent direct-digital-synthesizers RF sources with fast (rise-time of ∼60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.
We present a durable and inexpensive construction of a Johnson noise experiment suitable for advanced undergraduate students. By measuring the root-mean-square voltage noises for different resistors and taking into account the input capacitance of the amplifier circuit, we demonstrate that the experimental setup is capable of measuring the value of the Boltzmann’s constant to be J K −1 . The setup also allows us to determine the capacitance of an RG-58/U cable to be 80 ± 3 pF m −1 . We also provide observations from two years of teaching this experiment, containing common student pitfalls. Finally, we discuss possible adjustments of the experiment according to a time constraint.
We present a simple experiment to determine absolute zero temperature by measuring the Johnson noise of a thermistor. Using the thermistor itself as a temperature sensor, we measure the thermistor voltage noise at different temperatures by submerging the thermistor in hot and cold water contained in a thermally insulated cup. A linear fit of the data yields an absolute zero temperature of −274 ± 14 °C, agreeing with the accepted value. The experiment is simple enough to be performed at most universities as a part of an undergraduate experimental physics course.