Demetris Chrysostomou

Demetris Chrysostomou

Auto-generated profile, based on publicly available information

Demetris Chrysostomou

Department of Electrical Sustainable Energy Delft University of Technology South Holland The Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
UMUros Markovic
Uros Markovic
DCDemetris Chrysostomou
Demetris Chrysostomou
PAPetros Aristidou
Petros Aristidou
GHGabriela Hug
Gabriela Hug

10 January 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
DCDimitris Chrysostomou
Dimitris Chrysostomou
ADAndreas Dimitriou
Andreas Dimitriou
NKNikolaos D. Kokkinos
Nikolaos D. Kokkinos
CCC. A Charalambous
C. A Charalambous
Short-term Electromagnetic Interference (EMI) pertains to the total result produced by the occurrence of intermittent, inductive and conductive couplings on a buried pipeline system. For example, this type of EMI takes place when considering the fault conditions of a single a.c. power line, acting in the nearby vicinity of a pipeline system. In the context of this paper, the effect of the short-term EMI is unfolded through a real case study. This case study involves a 20.7 MW Wind Park with extended underground power cable connections, which are laid nearby a high-pressure gas pipeline system. In particular, the impact of critical fault events, associated with the Wind Park's power cables, on the pipeline system is comprehensively assessed. The assessment is achieved by the concurrent use of two powerful software tools that are respectively eligible for the accurate short-circuit analysis of the electrical circuit of the Wind Park and for EMI evaluation on the pipeline. To this extent, the simulation results are thoroughly discussed and an effective mitigation solution is evidently presented.

2 September 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
DCDemetris Chrysostomou
Demetris Chrysostomou
Jose Luis Rueda TorresJose Luis Rueda Torres
Jose Luis Rueda Torres
JCJochen Lorenz Cremer
Jochen Lorenz Cremer
Power system operators require advanced applications in the control centers to tackle increasingly variable power transfers effectively. One urgently needed application concerns estimating the feasible available aggregated flexibility from a power system network, which can be effectively deployed to mitigate issues in interconnected networks. This paper proposes the TensorConvolution+ algorithm to address the above application. Unlike related literature approaches, TensorConvolution+ estimates the density of feasible flexibility combinations to reach a new operating point within the p-q flexibility area. This density can improve the decision-making of system operators for efficient and safe flexibility deployment. The proposed algorithm applies to radial and meshed networks, is adaptable to new operational conditions, and can consider scenarios with disconnected flexibility areas. Using convolutions and tensors, the algorithm efficiently aggregates the combinations of flexibility providers’ adjustable power output that can occur for each flexibility area set point. Simulations on the meshed Oberrhein and radial CIGRE test networks illustrate the effectiveness of TensorConvolution+ for flexibility estimation with high numerical confidence and a minor computing effort. Additional simulations highlight how system operators can interpret the estimated density of feasible flexibility combinations for decision-making purposes, the algorithm’s capability to estimate disconnected flexibility areas, and adapt to new operating conditions.

1 June 2019
Verified
Conference Paper
Closed access
DCD. Chrysostomou
D. Chrysostomou
ADA. Dimitriou
A. Dimitriou
NKN. Kokkinos
N. Kokkinos
CCC. A. Charalambous
C. A. Charalambous
Short-term Electromagnetic Interference (EMI) pertains to the total result produced by the occurrence of intermittent, inductive and conductive couplings on a buried pipeline system. For example, this type of EMI takes place when considering the fault conditions of a single a.c. power line, acting in the nearby vicinity of a pipeline system. In the context of this paper, the effect of the short-term EMI is unfolded through a real case study. This case study involves a 20.7 MW Wind Park with extended underground power cable connections, which are laid nearby a high-pressure gas pipeline system. In particular, the impact of critical fault events, associated with the Wind Park's power cables, on the pipeline system is comprehensively assessed. The assessment is achieved by the concurrent use of two powerful software tools that are respectively eligible for the accurate short-circuit analysis of the electrical circuit of the Wind Park and for EMI evaluation on the pipeline.

26 June 2025 in SoftwareX
Verified
Journal Article
Open access
DCDemetris Chrysostomou
Demetris Chrysostomou
JTJosé Luis Rueda Torres
José Luis Rueda Torres
JCJochen Lorenz Cremer
Jochen Lorenz Cremer

20 November 2025 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
DCDemetris Chrysostomou
Demetris Chrysostomou
Jose Luis Rueda TorresJose Luis Rueda Torres
Jose Luis Rueda Torres
JCJochen Lorenz Cremer
Jochen Lorenz Cremer