Purpose: Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measureYvin a vessel‐specific manner.Theory: The method,T2‐Relaxation‐Under‐Phase‐Contrast MRI, utilizes complex subtraction of phase‐contrast to isolate pure blood signal, applies nonslice‐selectiveT2‐preparation to measureT2, and convertsT2to oxygenation using a calibration plot.Methods: Following feasibility demonstration, several technical aspects were examined, including validation with an established globalYvtechnique, test–retest reproducibility, sensitivity to detect oxygenation changes due to hypoxia and caffeine challenges, applicability of echo‐planar‐imaging (EPI) acquisition to shorten scan duration, and ability to study veins with a caliber of 1–2 mm.Results: T2‐Relaxation‐Under‐Phase‐Contrast was able to simultaneously measureYvin all major veins in the brain, including sagittal sinus, straight sinus, great vein, and internal cerebral vein.T2‐Relaxation‐Under‐Phase‐Contrast results showed an excellent agreement with the reference technique, high sensitivity to oxygenation changes, and test–retest variability of 3.5 ± 1.0%. The use of segmented‐EPI was able to reduce the scan duration to 1.5 minutes. It was also feasible to study pial veins and deep veins.Conclusion: T2‐Relaxation‐Under‐Phase‐Contrast MRI is a promising technique for vessel‐specific oxygenation measurement.Magn Reson Med 71:978–989, 2014. © 2013 Wiley Periodicals, Inc.