Guo-Xuan Xu

Guo-Xuan Xu

Auto-generated profile, based on publicly available information

Guo-Xuan Xu

Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GXGuo-Xuan Xu
Guo-Xuan Xu
PCPei-Yu Chen
Pei-Yu Chen
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
Chih-Chung HuangChih-Chung Huang
Chih-Chung Huang
Objective: Ultrasound (US) shear wave elasticity imaging (SWEI) is a mature technique for diagnosing the elasticity of isotropic tissues. However, the elasticity of anisotropic tissues, such as muscle and tendon, cannot be diagnosed correctly using SWEI because the shear wave velocity (SWV) varies with tissue fiber orientations. Recently, SWEI has been studied for measuring the anisotropic properties of muscles by rotating the transducer; however, this is difficult for clinical practice. Methods: In this study, a novel dual-direction shear wave imaging (DDSWI) technique was proposed for visualizing the mechanical anisotropy of muscles without rotation. Longitudinal and transverse shear waves were created by a specially designed external vibrator and supersonic pushing beam, respectively; the SWVs were then tracked using ultrafast US imaging. Subsequently, the SWV maps of two directions were obtained at the same scanning cross section, and the mechanical anisotropy was represented as the ratio between them at each pixel. Results: The performance of DDSWI was verified using a standard phantom, and human experiments were performed on the gastrocnemius and biceps brachii. Experimental results of phantom revealed DDSWI exhibited a high precision of <0.81% and a low bias of <3.88% in SWV measurements. The distribution of anisotropic properties in muscle was visualized with the anisotropic ratios of 1.54 and 2.27 for the gastrocnemius and biceps brachii, respectively. Conclusion: The results highlight the potential of this novel anisotropic imaging in clinical applications because the conditions of musculoskeletal fiber orientation can be easily and accurately evaluated in real time by DDSWI.

1 January 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HCHung-Jui Chen
Hung-Jui Chen
HCHao-Chun Chuang
Hao-Chun Chuang
GXGuo-Xuan Xu
Guo-Xuan Xu
CCChien Chen
Chien Chen
WSWei-Ren Su
Wei-Ren Su
Chih-Chung HuangChih-Chung Huang
Chih-Chung Huang
The shoulder is the most mobile joint in the human body, thus requiring intricate coordination of adjacent muscles. Patients suffered from rotator cuff muscle Injuries have several typical symptoms include shoulder pain and difficulty raising the arm, thus reducing work efficiency, and compromising the quality of life. Ultrasound has been used widely for shoulder soft tissue imaging as well as ultrasound elastography was introduced in shoulder examination for the dilemma of treating degenerative rotator cuff tears. However, most of ultrasound examination was performed under a static condition. Providing dynamic information from shoulder muscle are important in clinical applications because the pains sometime come from various positions of shoulder during moving. In this study, a customized wearable T-shaped ultrasound transducer (128+128 elements) was proposed for shoulder dual-direction shear wave elastography (DDSWE) which provides the SWE for both longitudinal (SW along the muscle fiber) and transverse (SW cross the muscle fiber) directions dynamically. An optical tracking system was synchronized with ultrasound imaging system to capture shoulder movements in 3-D space with their corresponding ultrasound images. The performance of DDSWE and the accuracy of optical tracking were verified by phantom experiments. Human studies were carried out from volunteers as they are moving their arms. Experimental results shows that the bias and precision for the proposed DDSWE in elastic phantom were about 6% and 1.2 % for both directions, respectively. A high accuracy of optical tracking was observed using 3-D motor stage experimental setup. Human experiments shows that the shear wave velocities (SWVs) were increased with the angles of shoulder abduction, the average transverse and longitudinal SWVs were increase from 2.24 m/s to 3.35 m/s and 2.95 m/s to 5.95 m/s with abduction angle from 0° to 60°, respectively, which they are anisotropic-dependent. All the experimental results indicates that the proposed wearable ultrasound DDSWE can quantify the mechanical properties of shoulder muscles dynamically, thereby may help surgeons and physical therapists determine whether the intensity of rehabilitation shoulder be tuned down or escalated in the future.

5 September 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GXGuo-Xuan Xu
Guo-Xuan Xu
PCPei-Yu Chen
Pei-Yu Chen
Chih-Chung HuangChih-Chung Huang
Chih-Chung Huang
High-resolution ultrasound shear wave elastography has been used to determine the mechanical properties of hand tendons. However, because of fiber orientation, tendons have anisotropic properties; this results in differences of shear wave velocity (SWV) between ultrasound scanning cross sections. Rotating transducers can be used to achieve full-angle scanning. However, this technique is inconvenient to implement in clinical settings. Therefore, in this study, high-frequency ultrasound (HFUS) dual-direction shear wave imaging (DDSWI) based on two external vibrators was used to create both transverse and longitudinal shear waves in the human flexor carpi radialis tendon. SWV maps from two directions were obtained using 40-MHz ultrafast imaging at the same scanning cross section. The anisotropic map was calculated pixel by pixel, and 3D information was obtained using mechanical scanning. A standard phantom experiment was then conducted to verify the performance of the proposed HFUS DDSWI technique. Human studies were also conducted where volunteers assumed three hand postures: relaxed (Rel), full fist (FF), and tabletop (TT). The experimental results indicated that both the transverse and the longitudinal SWVs increased due to tendon flexion. The transverse SWV surpassed the longitudinal SWV in all cases. The average anisotropic ratios for the Rel, FF, and TT hand postures were 1.78, 2.01, and 2.21, respectively. Both the transverse and the longitudinal SWVs were higher at the central region of the tendon than at the surrounding region. In conclusion, the proposed HFUS DDSWI technique is a high-resolution imaging technique capable of characterizing the anisotropic properties of tendons in clinical applications.