5 July 2019 in IEEE Access
Verified
Journal Article
Open access
XZxipeng zhang
xipeng zhang
NTNengling Tai
Nengling Tai
PWPan Wu
Pan Wu
CFChunju Fan
Chunju Fan
XZXiaodong Zheng
Xiaodong Zheng
WHWentao Huang
Wentao Huang
This paper proposes a theory for locating line fault based on the basic principle of time reversal. The proof has five steps. Firstly, the theoretical voltage and current at the ends of the line are calculated based on the transmission equation of the line in the additional network after line fault occurred. Secondly, the loss and lossless mirror line are established according to the parameters of the actual line, respectively. Thirdly, the values of the implemented sources at the ends of the mirror line are calculated based on the conjugate complex of the theoretical values of voltage and current in the first step. Fourthly, the RMS value of the fault current is calculated by assuming that fault occurs at every point of the mirror line. Finally, we should identify that there is only one peak value among all the RMS values and it exists at the actual fault location. In this paper, the fault location theory is proved with and without reflected waves by using the transmission equation of a single line. It is further proved in the mixed line that consists of two lines of different parameters considering the reflections.

5 July 2019 in IEEE Access
Verified
Journal Article
Open access
XZxipeng zhang
xipeng zhang
NTNengling Tai
Nengling Tai
PWPan Wu
Pan Wu
CFChunju Fan
Chunju Fan
XZXiaodong Zheng
Xiaodong Zheng
WHWentao Huang
Wentao Huang
Three time-reversal-based fault location methods are derived from the theoretical part of this paper, which are named currents-in-time-domain method, forward-currents-in-frequency-domain method, and forward-currents-in-frequency-domain-with-compensation method, respectively. The first proposed method utilizes only the decomposed transient currents in time domain to calculate the RMS values of the fault currents of assumed fault in lossless mirror line. The location where the peak value is located is the calculated fault location. The second method uses the forward current in frequency domain to calculate the RMS values of the fault currents of assumed fault in loss mirror line. The location where the minimum value is located is the calculated fault location. The third method firstly calculates the RMS values of fault currents of assumed fault in lossless mirror line, and the fault location is selected from the peak value. Then the final fault location result is compensated by the pre-calculated error for each assumed fault location. A two-terminal AC transmission system is established for testing these three methods. The frequency dependent lines including homogeneous and inhomogeneous lines are taken into the simulated system for a large number of tests, respectively.