19 March 2021 in Proceedings of the National Academy of Sciences
Significance: Ion selectivity is a fundamental property of ion channels. Potassium channels exhibit an unusual selectivity, allowing passage of larger K + ions (ionic radius of 1.3 Å) over smaller Na + ions (1.0 Å); the mechanism underlying the small ion rejecting selectivity remains unknown. Here, we applied Na + as a probe for examining the pore of a prototypical potassium channel and found slight Na + conduction across the pore. Na + traced a tortuous trajectory in the narrow pore, with multiple Na + ions trapped here and there, leading to slow elution. Contrarily, K + passed straight, with three ions moving together rapidly. Na + and K + take different paths and interactions in the pore, which creates dramatic contrast in the conduction rates of Na + and K + .
22 October 2024 in ACS Nano
The biological membrane is not just a platform for information processing but also a field of mechanics. The lipid bilayer that constitutes the membrane is an elastic body, generating stress upon deformation, while the membrane protein embedded therein deforms the bilayer through structural changes. Among membrane-protein interplays, various channel species act as tension-current converters for signal transduction, serving as elementary processes in mechanobiology. However, in situ studies in chaotically complex cell membranes are challenging, and characterizing the tension dependency of mechanosensitive channels remains semiquantitative owing to technical limitations. Here, we developed a programmable membrane tension-control apparatus on a lipid bilayer system. This synthetic membrane system [contact bubble bilayer (CBB)] uses pressure to drive bilayer tension changes via the Young-Laplace principle, whereas absolute bilayer tension is monitored in real-time through image analysis of the bubble geometry via the Young principle. Consequently, the mechanical nature of the system permits the implementation of closed-loop feedback control of bilayer tension (tension-clamp CBB), maintaining a constant tension for minutes and allowing stepwise tension changes within a hundred milliseconds in the tension range of 0.8 to 15 mN·m-1. We verified the system performance by examining the single-channel behavior of tension-dependent KcsA and TREK-1 potassium channels under scheduled tension time courses prescribed via visual interfaces. The result revealed steady-state activity and dynamic responses to the step tension changes, which are essential to the biophysical characterization of the channels. The apparatus explores a frontier for quantitative mechanobiology studies and promotes the development of a tension-operating experimental robot.
3 June 2021 in FEBS Letters
Biological structures with highly curved membranes, such as caveolae and transport vesicles, are essential for signal transduction and membrane trafficking. Although membrane proteins in these structures are subjected to physical stress due to the curvature of the lipid bilayers, the effect of this membrane curvature on protein structure and function remains unclear. In this study, we established an experimental procedure to evaluate membrane curvature‐induced structural changes in the prototypical potassium channel KcsA. The effect of a large membrane curvature was estimated using fluorescently labeled KcsA by incorporating it into liposomes with a small diameter (< 30 nm). We found that a large membrane curvature significantly affects the activation gate conformation of the KcsA channel.
14 November 2023 in iScience
KcsA is a potassium channel with a plethora of structural and functional information, but its activity in the KcsA-producing actinomycete membranes remains elusive. To determine lipid species involved in channel-modulation, a surface plasmon resonance (SPR)-based methodology, characterized by immobilization of membrane proteins under a membrane environment, was applied. Dianionic cardiolipin (CL) showed extremely higher affinity for KcsA than monoanionic lipids. The SPR experiments further demonstrated that CL bound not only to the N-terminal M0 helix, a lipid-sensor domain, but to the M0 helix-deleted mutant. In contrast, monoanionic lipids interacted primarily with the M0 helix. This indicates the presence of an alternative CL-binding site, plausibly in the transmembrane domain. Single-channel recordings demonstrated that CL enhanced channel opening in an M0-independent manner. Taken together, the action of monoanionic lipids is exclusively mediated by the M0 helix, while CL binds both the M0 helix and its specific site, further enhancing the channel activity.
16 June 2024 in FEBS Letters
This study investigated how membrane thickness and tension modify the gating of KcsA potassium channels when simultaneously varied. The KcsA channel undergoes global conformational changes upon gating: expansion of the cross‐sectional area and longitudinal shortening upon opening. Thus, membranes impose differential effects on the open and closed conformations, such as hydrophobic mismatches. Here, the single‐channel open probability was recorded in the contact bubble bilayer, by which variable thickness membranes under a defined tension were applied. A fully open channel in thin membranes turned to sporadic openings in thick membranes, where the channel responded moderately to tension increase. Quantitative gating analysis prompted the hypothesis that tension augmented the membrane deformation energy when hydrophobic mismatch was enhanced in thick membranes.