Donald A. Bender

Donald A. Bender

Auto-generated profile, based on publicly available information

Donald A. Bender

Washington State Univ, Dept Civil & Environ Engn, Pullman, WA 99164 USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Journal of Structural Engineering
Verified
Journal Article
Closed access
DGDrew A. Graham
Drew A. Graham
DCDavid M. Carradine
David M. Carradine
DBDonald A. Bender
Donald A. Bender
JDJ. Daniel Dolan
J. Daniel Dolan
Low-rise buildings are typically designed with shear walls and horizontal diaphragms to resist lateral load during windstorms and earthquakes. Although seismic performance and lateral load resistance behavior are generally well-understood for light-frame wood construction, this is not true for log construction. Research is needed to characterize log shear wall behavior subject to racking loads, and to develop recommendations for designing log walls to resist lateral loads from seismic or wind events. Monotonic and reverse-cyclic tests were conducted on log shear walls with 1:1, 2:1, and 4:1 aspect ratios. These walls showed higher resistance than conventional light-frame shear walls and similar hysteretic behavior to concrete and masonry shear walls. Log walls withstood large in-plane displacements without significant load reduction using lateral bracing typical of that used for light-frame wall testing; however, the test procedure would be improved by providing full-wall support to resist out-of-plane displacements of log shear walls. Design recommendations were developed based on the experiments reported herein.

29 July 2019 in BioResources
Verified
Journal Article
Closed access
JDJ. Daniel Dolan
J. Daniel Dolan
AWAlex Wilson
Alex Wilson
KBKristin Brandt
Kristin Brandt
DBDonald A. Bender
Donald A. Bender
MWMichael P. Wolcott
Michael P. Wolcott
Cross-laminated timber (CLT) construction has received significant attention for potential North American markets; however, few claims have been substantiated with structural design details that assess the amount of CLT to be used in various classifications of buildings. This article presents a design process used for the development of archetype buildings to estimate the potential CLT demand. Three types of structural systems were identified: platform construction, rocking walls with a separate gravity system, and hybrid construction consisting of reinforced concrete elevator cores and rocking walls. Platform construction was used for buildings 1 to 6 stories in height, the rocking wall system was used for buildings 6 to 12 stories in height, and the hybrid structural system was used for buildings 12 to 18 stories in height. The assumptions and design process for each of these archetypes are presented in this paper. Based on the structural analyses, CLT use factors were developed for predicting market demand as well as cost estimation of CLT building projects.

1 January 2010 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
DGDrew A. Graham
Drew A. Graham
DCDavid M. Carradine
David M. Carradine
DBDonald A. Bender
Donald A. Bender
JDJ. Daniel Dolan
J. Daniel Dolan
The log building industry favors simple to install mechanical connections between log layers, also referred to as log courses, to facilitate fast and efficient construction. In active seismic regions, lag screws are commonly used: however, research is lacking on how these connections between log courses perform in monotonic and reverse-cyclic loading scenarios. For the current study, 406-mm-long logs were used to fabricate connection test specimens in a single-shear configuration to mimic a typical lag screw layout used in log shear wall construction. The intent of this study was to develop baseline data on these connections to relate log connection performance to full-scale log shear wall performance. A preliminary study of four commonly used lag screws of different sizes was conducted to assess the monotonic performance within log connections. Predictions of design capacities were calculated using the National Design Specification for Wood Construction which is based on derived equations from the European yield model. Predicted NDS design capacities were compared to experimental data. Design recommendations for deriving appropriate fastener spacing were provided along with fabrication parameters that were based on observed failure mechanisms. Tested connections exhibited high ductility, which is considered a positive attribute for seismic resistance, although reverse-cyclic tests revealed failures due to low-cycle fatigue of the lag screws, leading to prevalent cyclic stiffness degradation as displacements were increased.

1 February 2011 in Practice Periodical on Structural Design and Construction
Verified
Journal Article
Closed access
DBDonald A. Bender
Donald A. Bender
FWFrank E. Woeste
Frank E. Woeste
Creep deflection can be an important consideration in the design of metal plate–connected (MPC) wood trusses. Chapter 2 of the ANSI/TPI 1-2007 truss standard, referenced by the 2009 International Building Code (IBC), defines the responsibility of the registered design professional when specifying MPC wood trusses. Based on Section 2.3.2.4 (h) of the standard, the registered design professional shall provide design criteria that addresses in-service creep deflection behavior of flat roofs subject to ponding loads and floor trusses supporting stone or ceramic tile finishes. In this paper, we review relevant standards and research studies on creep behavior of MPC wood trusses and offer a rational calculation method based on 10- and 15-year test data for estimating creep deflection for parallel chord MPC wood trusses. Examples are included to illustrate the calculation method for determining a design creep factor that is related to the sustained load percentage relative to total design load. Some practical ways to reduce the potential for flat roof ponding are discussed and illustrated by an example that includes the application of the creep deflection test data.

1 September 2009 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
ASAndrew J. Schildmeyer
Andrew J. Schildmeyer
MWMichael Wolcott
Michael Wolcott
DBDonald A. Bender
Donald A. Bender
Wood-plastic composites have been recognized as versatile and practical materials for use in many light-structural uses. Recently, more structurally demanding applications have surfaced, which require an improved understanding of mechanical performance and design methodologies. Research addressing the influence of service temperature on mechanical performance with the goal of assigning structural design values is lacking. This study examines the effect of temperature on the mechanical performance of a polypropylene-pine composite formulation. Static tests were performed at temperatures between 21.1 and 80.0°C to determine the material constitutive relations and ultimate properties in tension and compression. A statistical approach was proposed to assess design thermal loads according to geographical location. Both Young’s modulus and ultimate stress were found to decrease with temperature while maximum strain increased linearly with temperature. Temperature adjustment factors were developed over the range...

1 November 2010 in Practice Periodical on Structural Design and Construction
Verified
Journal Article
Closed access
RKRobert E. Kimble
Robert E. Kimble
DBDonald A. Bender
Donald A. Bender
Built-up beams and columns comprised of dimension lumber fastened with nails, bolts or lag screws, are common in construction. Current design practice for stability checks is to use the lower-tail modulus of elasticity ( Emin ) value tabulated for dimension lumber; however, this ignores the averaging effect on Emin that occurs when the mechanically fastened laminations are constrained to deflect in unison. In this paper, we propose a method for checking stability of these assemblies that is based on established statistical theory. A factor ( Cs ) is proposed to adjust Emin value used in column and beam stability calculations to account for the reduced variability of E when the laminations are constrained to deflect together. Using Cs to account for the reduction of Emin variability produces more efficient designs with respect to stability. Two examples are provided and each results in larger design capacities compared to current design methods for built-up beams and columns.