1 April 2014 in Clinical Neurophysiology
1 April 2014 in Clinical Neurophysiology
6 March 2023 in Clinical Neurophysiology
This study examined (1) the utility of a clinical system to record acoustic change complex (ACC, an event-related potential recorded by electroencephalography) for assessing speech discrimination in infants, and (2) the relationship between ACC and functional performance in real life. Participants included 115 infants (43 normal-hearing, 72 hearing-impaired), aged 3-12 months. ACCs were recorded using [szs], [uiu], and a spectral rippled noise high-pass filtered at 2 kHz as stimuli. Assessments were conducted at age 3-6 months and at 7-12 months. Functional performance was evaluated using a parent-report questionnaire, and correlations with ACC were examined. The rates of onset and ACC responses of normal-hearing infants were not significantly different from those of aided infants with mild or moderate hearing loss but were significantly higher than those with severe loss. On average, response rates measured at 3-6 months were not significantly different from those at 7-12 months. Higher rates of ACC responses were significantly associated with better functional performance. ACCs demonstrated auditory capacity for discrimination in infants by 3-6 months. This capacity was positively related to real-life functional performance. ACCs can be used to evaluate the effectiveness of amplification and monitor development in aided hearing-impaired infants.
26 June 2014 in Journal of Neural Engineering
Objective. To evaluate the viability of disentangling a series of overlapping 'cortical auditory evoked potentials' (CAEPs) elicited by different stimuli using least-squares (LS) deconvolution, and to assess the adaptation of CAEPs for different stimulus onset-asynchronies (SOAs). Approach. Optimal aperiodic stimulus sequences were designed by controlling the condition number of matrices associated with the LS deconvolution technique. First, theoretical considerations of LS deconvolution were assessed in simulations in which multiple artificial overlapping responses were recovered. Second, biological CAEPs were recorded in response to continuously repeated stimulus trains containing six different tone-bursts with frequencies 8, 4, 2, 1, 0.5, 0.25 kHz separated by SOAs jittered around 150 (120-185), 250 (220-285) and 650 (620-685) ms. The control condition had a fixed SOA of 1175 ms. In a second condition, using the same SOAs, trains of six stimuli were separated by a silence gap of 1600 ms. Twenty-four adults with normal hearing (<20 dB HL) were assessed. Main results. Results showed disentangling of a series of overlapping responses using LS deconvolution on simulated waveforms as well as on real EEG data. The use of rapid presentation and LS deconvolution did not however, allow the recovered CAEPs to have a higher signal-to-noise ratio than for slowly presented stimuli. The LS deconvolution technique enables the analysis of a series of overlapping responses in EEG. Significance. LS deconvolution is a useful technique for the study of adaptation mechanisms of CAEPs for closely spaced stimuli whose characteristics change from stimulus to stimulus. High-rate presentation is necessary to develop an understanding of how the auditory system encodes natural speech or other intrinsically high-rate stimuli.
10 April 2020 in International Journal of Audiology
Objective: This study explored the feasibility of cortical automatic threshold estimation (CATE), a fully automated late auditory evoked potential (AEP) test, as an alternative to pure-tone audiometry for hearing threshold estimation for adults with dementia living in aged care. Design: A single group cross-sectional study was conducted. Participants’ dementia severity was determined through the Clinical Dementia Rating scale. Hearing thresholds were obtained for four audiometric frequencies in at least one ear by using both pure-tone audiometry and CATE. Study sample: Sixteen participants enrolled in the study, of which 14 completed at least one of the hearing tests. Twelve ears, from six participants, were included in the final correlation analysis. Results: Pearson correlation coefficients were significant between CATE and pure-tone audiometry for all frequencies: r2 = 0.52 (p = 0.008) for 500 Hz, r2 = 0.79 (p = 0.0001) for 1000 Hz, r2 = 0.71 (p = 0.0005) for 2000 Hz, and r2 = 0.92 (p < 0.0001) for 4000 Hz. Cortical thresholds were within 10 dB of behavioural thresholds for all four frequencies. Conclusions: Findings are encouraging for the feasibility of CATE as an alternative diagnostic test to pure-tone audiometry for adults living with dementia in aged care.
1 June 2016 in The Hearing Journal
This article brings together the work we have been doing at the National Acoustic Laboratories (NAL) to make cortical threshold testing easy, fast, and accurate. Our aim is to improve techniques for estimating hearing thresholds on people who, for whatever reason, are unable to give reliable behavioural responses to indicate that they have heard a sound. The particular techniques described have general applicability to cortical testing, and have been evaluated within a practical package that will become part of the HEARLab family of test modules. Cortical testing nicely complements auditory brainstem testing both because it is best carried out while the patient is awake rather than asleep, and it measures more of the auditory system compared with brainstem testing. Our eventual goal is to have a test that can be used for babies with auditory neuropathy spectrum disorder - in whom cortical thresholds can often be measured even though auditory brainstem responses are absent. We have not achieved that goal yet, but as the article shows, we developed a test that automatically produces reliable threshold estimates in older children and adults. The technique is highly automated - in principle, only one button press, and no human decision making or intervention, is needed to obtain an audiogram in both ears. Our philosophy is that if a computer is better able than humans to examine the consistency of the cortical responses to, say, 50 repeated stimulus presentations, and is able do this simultaneously for eight different stimuli, then it should be left to perform tests uninterrupted by humans! Clinicians should continue doing what they do best: deal with truly complex issues. These include understanding client beliefs and behaviors, and developing inferences from the results of diverse auditory tests.6 page(s