Selim Suner

Selim Suner

Auto-generated profile, based on publicly available information

Selim Suner

Department of Emergency Medicine, Alpert Medical School of Brown University, Providence, RI, USA

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2005 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SSS. Suner
S. Suner
MFM.R. Fellows
M.R. Fellows
CVC. Vargas-Irwin
C. Vargas-Irwin
GNG.K. Nakata
G.K. Nakata
JDJ.P. Donoghue
J.P. Donoghue
Multiple-electrode arrays are valuable both as a research tool and as a sensor for neuromotor prosthetic devices, which could potentially restore voluntary motion and functional independence to paralyzed humans. Long-term array reliability is an important requirement for these applications. Here, we demonstrate the reliability of a regular array of 100 microelectrodes to obtain neural recordings from primary motor cortex (MI) of monkeys for at least three months and up to 1.5 years. We implanted Bionic (Cyberkinetics, Inc., Foxboro, MA) silicon probe arrays in MI of three Macaque monkeys. Neural signals were recorded during performance of an eight-direction, push-button task. Recording reliability was evaluated for 18, 35, or 51 sessions distributed over 83, 179, and 569 days after implantation, respectively, using qualitative and quantitative measures. A four-point signal quality scale was defined based on the waveform amplitude relative to noise. A single observer applied this scale to score signal quality for each electrode. A mean of 120 (/spl plusmn/17.6 SD), 146 (/spl plusmn/7.3), and 119 (/spl plusmn/16.9) neural-like waveforms were observed from 65-85 electrodes across subjects for all recording sessions of which over 80% were of high quality. Quantitative measures demonstrated that waveforms had signal-to-noise ratio (SNR) up to 20 with maximum peak-to-peak amplitude of over 1200 /spl mu/v with a mean SNR of 4.8 for signals ranked as high quality. Mean signal quality did not change over the duration of the evaluation period (slope 0.001, 0.0068 and 0.03; NS). By contrast, neural waveform shape varied between, but not within days in all animals, suggesting a shifting population of recorded neurons over time. Arm-movement related modulation was common and 66% of all recorded neurons were tuned to reach direction. The ability for the array to record neural signals from parietal cortex was also established. These results demonstrate that neural recordings that can provide movement related signals for neural prostheses, as well as for fundamental research applications, can be reliably obtained for long time periods using a monolithic microelectrode array in primate MI and potentially from other cortical areas as well.

1 December 2004 in Quality and Safety in Health Care
Verified
Journal Article
Open access
PDF file
MSM J Shapiro
M J Shapiro
JMJ C Morey
J C Morey
SSS D Small
S D Small
VLV Langford
V Langford
CKC J Kaylor
C J Kaylor
GJGregory Jay
Gregory Jay
Objective: To determine if high fidelity simulation based team training can improve clinical team performance when added to an existing didactic teamwork curriculum. Setting: Level 1 trauma center and academic emergency medicine training program. Participants: Emergency department (ED) staff including nurses, technicians, emergency medicine residents, and attending physicians. Intervention: : ED staff who had recently received didactic training in the Emergency Team Coordination Course (ETCC®) also received an 8 hour intensive experience in an ED simulator in which three scenarios of graduated difficulty were encountered. A comparison group, also ETCC trained, was assigned to work together in the ED for one 8 hour shift. Experimental and comparison teams were observed in the ED before and after the intervention. Design: Single, crossover, prospective, blinded and controlled observational study. Teamwork ratings using previously validated behaviorally anchored rating scales (BARS) were completed by outside trained observers in the ED. Observers were blinded to the identification of the teams. Results: There were no significant differences between experimental and comparison groups at baseline. The experimental team showed a trend towards improvement in the quality of team behavior (p = 0.07); the comparison group showed no change in team behavior during the two observation periods (p = 0.55). Members of the experimental team rated simulation based training as a useful educational method. Conclusion: High fidelity medical simulation appears to be a promising method for enhancing didactic teamwork training. This approach, using a number of patients, is more representative of clinical care and is therefore the proper paradigm in which to perform teamwork training. It is, however, unclear how much simulator based training must augment didactic teamwork training for clinically meaningful differences to become apparent.

1 March 1990 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
JDJ. P. Donoghue
J. P. Donoghue
SSS. Suner
S. Suner
JSJ. N. Sanes
J. N. Sanes

1 March 1990 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
JSJ. N. Sanes
J. N. Sanes
SSS. Suner
S. Suner
JDJ. P. Donoghue
J. P. Donoghue

1 March 1988 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
JSJ N Sanes
J N Sanes
SSS Suner
S Suner
JLJ F Lando
J F Lando
JDJ P Donoghue
J P Donoghue
The potential for peripheral nerve injury to reorganize motor cortical representations was investigated in adult rats. Maps reflecting functional connections between the motor cortex and somatic musculature were generated with intracortical electrical stimulation techniques. Comparison of cortical somatotopic maps obtained in normal rats with maps generated from rats with a facial nerve lesion indicated that the forelimb and eye/eyelid representations expanded into the normal vibrissa area. Repeated testing from an electrode placed chronically in the motor cortex showed a shift from vibrissa to forelimb within hours after facial nerve transection. These comparatively quick changes in motor cortex representation pattern suggest that synaptic relations between motor cortex and somatic musculature are continually reshaped in adult mammals.

1 May 2008 in The Journal of Emergency Medicine
Verified
Journal Article
Closed access
SSSelim Suner
Selim Suner
RPRobert Partridge
Robert Partridge
ASAndrew Sucov
Andrew Sucov
JVJonathan Valente
Jonathan Valente
KCKerlen Chee
Kerlen Chee
GJGregory Jay
Gregory Jay