Chris Halling Dreyer

Chris Halling Dreyer

Auto-generated profile, based on publicly available information

Chris Halling Dreyer

Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Department of Orthopaedic Surgery and Traumatology, CORI - Centre for Orthopaedic Research and Innovation, Naestved-Slagelse-Ringsted Hospital, Denmark

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
CDChris H. Dreyer
Chris H. Dreyer
KKKristian Kjaergaard
Kristian Kjaergaard
MDMing Ding
Ming Ding
LQLing Qin
Ling Qin
To achieve optimal bone formation one of the most influential parameters has been mentioned to be adequate blood supply. Vascular endothelial growth factor (VEGF) is hereby of particular interest in bone regeneration, because of its primary ability to induce neovascularization and chemokine affection for endothelial cells (EC), and is considered to be the main regulator of vascular formation. However, the growth factor has yet to be implemented in a clinical setting in orthopaedic intervention surgery. We hypothesised that the development of VEGF in vivo for bone formation in the last decade had progressed towards clinical application since the latest systematic review from 2008. This systematic review recapped the last 13 years of in vivo bone regeneration using vascular endothelial growth factor (VEGF). A total of 1374 articles were identified using the PubMed search string (vegf or “vascular endothelial growth factor”) and (osteogen∗ or “bone formation” or “bone regeneration”). By 3 selection phases 24 published articles were included by the criteria of being in vivo, using only VEGF for bone formation, published after 2007 and written in English. Articles in vitro, written in different languages than English and older than 2007 was excluded. The most recent systematic review on this subject was published in 2008, with the latest included study from 01 to 11-2007. All included studies were classified based on animal, type of defect, scaffold, control group, type of VEGF, release rate, dosage of VEGF, time of evaluation and results. Each study was evaluated for risk of bias by modified CAMARADES quality assessment for the use in experimental animal studies. The score was calculated by peer review journal publication, use of control group, randomisation of groups, justified VEGF dosage, blinding of results, details on animal model, sample size calculation, comply with ethics and no conflict of interest. No clinical trials or human application studies were obtained from our search. Experimentally, 11 articles using solely VEGF for bone formation had a group or a timepoint significantly better than the corresponding control group. 18 articles revealed no significant difference of VEGF compared to the control group and 1 article reported a significant decreased bone growth using VEGF compared to control. Based on these results no clinical studies have yet been performed. However, indications in the best use of VEGF from experimental studies could be made towards that the optimal release is within the first three weeks, in defect models, with the best effect before eight weeks. Future designs should incorporate this with standardised and reproducible models for verification towards clinical practice. This systematic review aims to assess the existing literature to focus on methodologies and outcomes that can provide future knowledge regarding the solitary use of VEGF for bone regeneration in a clinical setting.

1 February 2021 in Journal of Materials Science & Technology
Verified
Journal Article
Closed access
HZHaiyue Zu
Haiyue Zu
KCKelvin Chau
Kelvin Chau
Temitope OlugbadeTemitope Olugbade
Temitope Olugbade
LPLulu Pan
Lulu Pan
CDChris Halling Dreyer
Chris Halling Dreyer
LQLing Qin
Ling Qin

1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CDChris H Dreyer
Chris H Dreyer
MRMarina Rasmussen
Marina Rasmussen
RPRasmus Hestehave Pedersen
Rasmus Hestehave Pedersen
SOSøren Overgaard
Søren Overgaard
MDMing Ding
Ming Ding
Introduction. In the field of orthopaedic surgery, the use of osteogenic material in larger defects is essential. Autograft and allograft are both known methods, and autograft is believed to be the best choice. But autograft is associated with additional invasive procedures which can prove difficult in fragile patients and can cause local side effect after bone harvest. For feasible purposes, the use of allograft is hereby rising and comparing efficacies, and the differences between autograft and allograft are essential for the clinical outcome for the patients. Method. 24 female Norwegian brown rats were included, 12 normal rats and 12 induced with osteoporosis (OP). OP inducement was verified in vivo by bone volume fraction (BV/TV) at 90 days after ovariectomy (OVX). The primary surgery in each rat consisted of a 2.5 × 3 mm hole in the proximal tibia, bilaterally. Autograft and allograft were randomly allocated in the right and left tibia. After an observation of 21 days, the rats were sacrificed. Tibia samples were harvested, micro‐CT scanned for bone inducement and microarchitectural properties, and then embedded for histology. Results. The OP induction was verified three months after the OVX by a reduction of 68.5% in the trabecular bone BV/TV compared to normal bone. Microarchitectural analysis and histology showed no significant differences in the bone‐forming capabilities between autograft and allograft in normal or osteoporotic bone after 3 weeks. Conclusion. This study did not demonstrate any difference between autograft and allograft in a normal or osteoporotic rat tibial defect model after 21 days, suggesting allograft is a good alternative to autograft.

19 March 2024 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
MBMichael Luke Connor Beagan
Michael Luke Connor Beagan
CDChris H. Dreyer
Chris H. Dreyer
LJLouise K. Jensen
Louise K. Jensen
HJHenrik E. Jensen
Henrik E. Jensen
TAThomas Emil Andersen
Thomas Emil Andersen
MDMing Ding
Ming Ding
Reliable animal models are critical for preclinical research and should closely mimic the disease. With respect to route of infection, pathogenic agent, disease progression, clinical signs, and histopathological changes. Sheep have similar bone micro- and macrostructure as well as comparable biomechanical characteristics to humans. Their use in bone research is established, however their use in bone infection research is limited. This systematic review will summarise the key features of the available bone infection models using sheep, providing a reference for further development, validation, and application. This systematic review was designed according to the PRISMA guidelines and registered with PROSPERO. Quality was assessed using SYRICLE's risk of bias tool adapted for animal studies. PubMed, MEDLINE, Web of Science and EMBASE were searched until March 2022.1921 articles were screened by two independent reviewers, and 25 were included for analysis. Models have been developed in nine different breeds. Staphylococcus aureus was used in the majority of models, typically inoculating 108 colony forming units in tibial or femoral cortical defects. Infection was established with either planktonic or biofilm adherent bacteria, with or without foreign material implanted. Most studies used both radiological and microbiological analyses to confirm osteomyelitis. There is convincing evidence supporting the use of sheep in bone infection models of clinical disease. The majority of sheep studied demonstrated convincing osteomyelitis and tolerated the infection with minimal complications. Furthermore, the advantages of comparable biology and biomechanics may increase the success for translating in vivo results to successful therapies. In the realm of preclinical research, the translation to viable clinical therapies is often perilous, and the quest for reliable and representative animal models remains paramount. This systematic review accentuates the largely untapped potential of sheep as large animal models, especially in bone infection research. The anatomical and biomechanical parallels between sheep and human bone structures position sheep as an invaluable asset for studying osteomyelitis and periprosthetic joint infection. This comprehensive exploration of the literature demonstrates the robustness and translational promise of these models. Furthermore, this article underscores the potential applicability for sheep in developing effective therapeutic strategies for human bone infections.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CDChris H. Dreyer
Chris H. Dreyer
NJNiklas Rye Jørgensen
Niklas Rye Jørgensen
SOSøren Overgaard
Søren Overgaard
LQLing Qin
Ling Qin
MDMing Ding
Ming Ding
Introduction. Mesenchymal stem cells (MSCs) and vascular endothelial growth factor (VEGF) are key factors in bone regeneration. Further stimulation should establish an enhanced cell environment optimal for vessel evolvement and hereby being able to attract bone‐forming cells. The aim of this study was to generate new bone by using MSCs and VEGF, being able to stimulate growth equal to allograft. Methods. Eight Texel/Gotland sheep had four titanium implants in a size of 10 × 12 mm inserted into bilateral distal femurs, containing a 2 mm gap. In the gap, autologous 3 × 106 MSCs seeded on hydroxyapatite (HA) granules in combination with 10 ng, 100 ng, and 500 ng VEGF release/day were added. After 12 weeks, the implant‐bone blocks were harvested, embedded, and sectioned for histomorphometric analysis. Bone formation and mechanical fixation were evaluated. Blood samples were collected for the determination of bone‐related biomarkers and VEGF in serum at weeks 0, 1, 4, 8, and 12. Results. The combination of 3 × 106 MSCs with 10 ng, 100 ng, and 500 ng VEGF release/day exhibited similar amount of bone formation within the gap as allograft (P > 0.05). Moreover, no difference in mechanical fixation was observed between the groups (P > 0.05). Serum biomarkers showed no significant difference compared to baseline (all P > 0.05). Conclusion. MSCs and VEGF exhibit significant bone regeneration, and their bone properties equal to allograft, with no systemic increase in osteogenic markers or VEGF with no visible side effects. This study indicates a possible new approach into solving the problem of insufficient allograft, in larger bone defects.

19 September 2017 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
CDChris H. Dreyer
Chris H. Dreyer
KKKristian Kjærgaard
Kristian Kjærgaard
NDNicholas Ditzel
Nicholas Ditzel
NJNiklas Rye Jørgensen
Niklas Rye Jørgensen
SOSøren Overgaard
Søren Overgaard
MDMing Ding
Ming Ding