27 June 2019 in Biomedical Optics Express
We demonstrate a swept source OCT-based ocular biometer integrated with an air-puff stimulus to study the reaction of the eye to mechanical stimulation in vivo. The system enables simultaneous measurement of the stimulus strength and high-speed imaging of the eye dynamics along the visual axis. We characterize the stimulus and perform optimization of the data acquisition for a proper interpretation of the results. Access to the dynamics of axial eye length allows for a determination of the eye retraction, which is used to correct the air-puff induced displacement of ocular structures. We define the parameters to quantify the reaction of the eye to the air puff and determine their reproducibility in a group of healthy subjects. We observe the corneal deformation process and axial wobbling of the crystalline lens. OCT biometer combined with the air puff is the first instrument with the potential to provide comprehensive information on the biomechanics of ocular components.
20 July 2023 in Optics Letters
This pilot study reports the development of optical coherence tomography (OCT) split-spectrum amplitude-decorrelation optoretinography (SSADOR) that measures spatially resolved photoreceptor response to light stimuli. Using spectrally multiplexed narrowband OCT, SSADOR improves sensitivity to microscopic changes without the need for cellular resolution or optical phase detection. Therefore, a large field of view (up to 3 × 1 mm2 demonstrated) using conventional OCT instrument design can be achieved, paving the way for clinical translation. SSADOR promises a fast, objective, and quantifiable functional biomarker for photoreceptor damage in the macula.
1 May 2019 in Investigative Ophthalmology & Visual Science
JRJagoda Rzeszewska-Zamiara
Jagoda Rzeszewska-Zamiara
Purpose: To analyze the dynamics of all optical components of the eye and the behavior of the eyeball under air-puff conditions in vivo. To determine the impact of the intraocular pressure (IOP) on the air-puff-induced deformation of the eye. Methods: Twenty eyes of 20 healthy subjects were included in this study. The dynamics of the ocular components, such as the cornea, the crystalline lens, and the retina, was measured by a prototype swept source optical coherence tomography biometer integrated with the air-puff system. The system allows to acquire a series of axial scans at the same location as a function of time with no transverse scanning. Several parameters were extracted from optical coherence tomography data. The IOP was measured using a Goldmann applanation tonometry. The measurements of the eyes were performed before and 2 hours after administration of IOP-reducing drops, namely, 0.2 % brimonidine tartrate. Results: There is a statistically significant correlation of corneal thickness, vitreous depth, and eye length with IOP. The deformation amplitudes of the cornea and the crystalline lens are inversely proportional to the IOP, but statistical significance is achieved only for the cornea. The crystalline lens is displaced without compression, and the return has the form of wobbling. The reduction of IOP level induces corresponding changes in the extracted parameters. Conclusions: Optical biometry combined with air puff provides comprehensive information on the in vivo behavior of all ocular components, including the crystalline lens. Measurement of the axial length dynamics of during deformation enables correcting the deformation for eye retraction.
2 September 2020 in Biomedical Optics Express
We demonstrate in vivo three-dimensional (3-D) visualization of crystalline lens sutures in healthy eyes using swept source optical coherence tomography (SS-OCT). Volumetric data sets of the crystalline lenses were acquired and processed to obtain enhanced contrast projection images and to extract suture patterns in both anterior and posterior lens. The results presented different types of the sutures including Y-sutures, simple and complex star sutures. Age-related changes in suture arrangement were characterized quantitatively. Crystalline lens suture imaging with SS-OCT might be a useful tool in fundamental studies on development and ageing of human lens.
3 December 2021 in Optics Express
Cataracts are a common ocular pathology involving an increase in the amount of intraocular light scattering. This causes vision impairment by blurring and reducing the contrast in retinal images. The current treatment for this pathology is cataract surgery, which is an invasive procedure with possible side effects, such as corneal edema, infection or retinal detachment among others. In this work, we propose a non-invasive approach to improve vision through the cataractous lenses by manipulating the wavefront of the incident light. By using a fluorescent signal as feedback (similar to the inherent fluorescence of the lipofuscin pigment at the retina) we show the capability of improving the point spread function (PSF) of the eye in a single pass through the artificial eye’s optics, while the feedback signal is measured in a double-pass configuration, making the whole system completely non-invasive, opening new possibilities for real-time vision correction through cataracts with wearable devices.
1 December 2019 in Contact Lens and Anterior Eye