1 June 2023 in Publications of the Astronomical Society of the Pacific
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4 m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5 m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 yr, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.
1 April 2023 in Publications of the Astronomical Society of the Pacific
The Mid-Infrared Instrument (MIRI) extends the reach of the James Webb Space Telescope (JWST) to 28.5 μm. It provides subarcsecond-resolution imaging, high sensitivity coronagraphy, and spectroscopy at resolutions of λ/Δλ ∼ 100–3500, with the high-resolution mode employing an integral field unit to provide spatial data cubes. The resulting broad suite of capabilities will enable huge advances in studies over this wavelength range. This overview describes the history of acquiring this capability for JWST. It discusses the basic attributes of the instrument optics, the detector arrays, and the cryocooler that keeps everything at approximately 7 K. It gives a short description of the data pipeline and of the instrument performance demonstrated during JWST commissioning. The bottom line is that the telescope and MIRI are both operating to the standards set by pre-launch predictions, and all of the MIRI capabilities are operating at, or even a bit better than, the level that had been expected. The paper is also designed to act as a roadmap to more detailed papers on different aspects of MIRI.
1 December 2023 in The Planetary Science Journal
The Near-Earth Object (NEO) Surveyor mission is a NASA Observatory designed to discover and characterize asteroids and comets. The mission’s primary objective is to find the majority of objects large enough to cause severe regional impact damage (>140 m in effective spherical diameter) within its 5 yr baseline survey. Operating at the Sun–Earth L1 Lagrange point, the mission will survey to within 45° of the Sun in an effort to find objects in the most Earth-like orbits. The survey cadence is optimized to provide observational arcs long enough to distinguish near-Earth objects from more distant small bodies that cannot pose an impact hazard reliably. Over the course of its survey, NEO Surveyor will discover ∼200,000–300,000 new NEOs down to sizes as small as ∼10 m and thousands of comets, significantly improving our understanding of the probability of an Earth impact over the next century.
12 October 2022 in Nature Astronomy
23 December 2020 in Publications of the Astronomical Society of the Pacific
Arsenic doped back illuminated blocked impurity band (BIBIB) silicon detectors have advanced near and mid-IR astronomy for over thirty years; they have high quantum efficiency (QE), especially at wavelengths longer than 10 μm, and a large spectral range. Their radiation hardness is also an asset for space based instruments. Three examples of Si:As BIBIB arrays are used in the Mid-InfraRed Instrument (MIRI) of the James Webb Space Telescope (JWST), observing between 5 and 28 μm. In this paper, we analyze the parameters leading to high quantum efficiency (up to ∼60%) for the MIRI devices between 5 and 10 μm. We also model the cross-shaped artifact that was first noticed in the 5.7 and 7.8 μm Spitzer/IRAC images and has since also been imaged at shorter wavelength (≤10 μm) laboratory tests of the MIRI detectors. The artifact is a result of internal reflective diffraction off the pixel-defining metallic contacts to the readout detector circuit. The low absorption in the arrays at the shorter wavelengths enables photons diffracted to wide angles to cross the detectors and substrates multiple times. This is related to similar behavior in other back illuminated solid-state detectors with poor absorption, such as conventional CCDs operating near 1 μm. We investigate the properties of the artifact and its dependence on the detector architecture with a quantum-electrodynamic (QED) model of the probabilities of various photon paths. Knowledge of the artifact properties will be especially important for observations with the MIRI LRS and MRS spectroscopic modes.
1 July 2023 in Publications of the Astronomical Society of the Pacific
The detectors in the Mid-Infrared Instrument (MIRI) of the James Webb Space Telescope (JWST) are arsenic-doped silicon impurity band conduction (Si:As IBC) devices and are direct descendants of the Spitzer IRAC long wavelength arrays (channels 3 and 4). With appropriate data processing, they can provide excellent performance. In this paper we discuss the various non-ideal behaviors of these detectors that need to be addressed to realize their potential. We have developed a set of algorithms toward this goal, building on experience with previous similar detector arrays. The MIRI-specific stage 1 pipeline algorithms, of a three stage JWST calibration pipeline, were developed using pre-flight tests on the flight detectors and flight spares and have been refined using flight data. This paper describes these algorithms, which are included in the first stage of the JWST Calibration Pipeline for the MIRI instrument.