Nasiq Hasan

Nasiq Hasan

Auto-generated profile, based on publicly available information

Nasiq Hasan

Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA 15260, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
PDF file
NHNasiq Hasan
Nasiq Hasan
AKAtul Kumar
Atul Kumar
PKPrateek Kakkar
Prateek Kakkar
VMVineet Mutha
Vineet Mutha
RKR Karthikeya
R Karthikeya
RRRaghav Ravani
Raghav Ravani
Purpose: To compare clinical outcomes of patients undergoing macular hole surgery with heads-up three-dimensional (3D) viewing system and conventional microscope. Methods: In all, 50 eyes of 50 patients with stage 3 or 4 macular hole were randomized and macular hole surgery [inverted internal limiting membrane (ILM) flap technique] was performed in 25 eyes using 3D viewing system and 25 eyes using conventional microscope. All surgeries were performed by a single surgeon. Patients were followed up for a period of 3 months. Logarithm of the minimum angle of resolution (logMAR) visual acuity, macular hole index, intraoperative parameters such as total surgical time, total ILM peel time, number of flap initiations, duration of Brilliant Blue G dye exposure, illumination intensity, postoperative logMAR visual acuity, and macular hole closure rates were recorded and compared between the two groups. Results: The mean age was 67.92 ± 7.95 and 67.96 ± 4.78 years in both groups, respectively (P = 0.98). Gender (P = 0.38) and right versus left eye (P = 0.39) were also comparable. Preoperative and postoperative best-corrected visual acuity (P = 0.86, 0.92), macular hole index (P = 0.96), total surgical time (P = 0.56), total ILM peel time (P = 0.49), number of flap initiations (P = 0.11), and macular hole closure rates (P = 0.61) were not statistically significant when compared between the two groups. Illumination intensity of microscope (100% vs 45%) and endoillumination (40% vs 13%) were significantly less in the 3D viewing system. Conclusion: The clinical outcomes of macular hole surgery using 3D viewing system are not inferior to that of conventional microscopes, and it has the added advantages of better ergonomics, reduced phototoxicity, peripheral visualization, magnification, and less asthenopia, and it serves as a good educational tool.

18 October 2024 in Survey of Ophthalmology
Verified
Journal Article
Open access
ESElham Sadeghi
Elham Sadeghi
NVNicola Valsecchi
Nicola Valsecchi
ERElham Rahmanipour
Elham Rahmanipour
MEMahsa Ejlalidiz
Mahsa Ejlalidiz
NHNasiq Hasan
Nasiq Hasan
Jay ChhablaniJay Chhablani
Jay Chhablani
Age-related macular degeneration (AMD) is the leading cause of central visual impairment in the elderly. The exact pathophysiological mechanisms for AMD remain uncertain. Several studies suggest that choroidal abnormalities and alterations are critical in AMD progression. The transition from manual to automated segmentation and binarization techniques has resulted in accurate and precise measurements of different choroidal parameters. These qualitative and quantitative parameters, known as choroidal imaging biomarkers, have advanced from basic vertical subfoveal choroidal thickness to more intricate 3-dimensional choroidal reconstruction methods in the last decade. Therefore, a comprehensive evaluation of choroidal metrics may investigate valuable insights into AMD, potentially guiding the future development of customized therapeutic strategies and personalized patient care in AMD management. We describe the role of different choroidal biomarkers in evaluating patients with AMD and their contribution to management.

1 January 2020 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
PDF file
NHNasiq Hasan
Nasiq Hasan
LDLubhavni Dewan
Lubhavni Dewan
NANeelima Aron
Neelima Aron
RCRohan Chawla
Rohan Chawla
DSDheepak Sundar
Dheepak Sundar

21 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
NHNasiq Hasan
Nasiq Hasan
AGAdarsh Gadari
Adarsh Gadari
SVSharat Chandra Vupparaboina
Sharat Chandra Vupparaboina
ESElham Sadeghi
Elham Sadeghi
GGGiulia Gregori
Giulia Gregori
Jay ChhablaniJay Chhablani
Jay Chhablani
Purpose: To validate a deep learning algorithm for automated segmentation and quantitative assessment of the ellipsoid zone (EZ) and RPE–Bruch’s membrane (BM) complex in healthy and geographic atrophy (GA) eyes. Methods: In this retrospective study, SD-OCT volume scans from 30 healthy and 30 eyes with GA were analysed. NMI-Outer Retina Analyzer was used to segment the inner EZ, inner RPE, and outer BM. Average thicknesses of EZ-RPE, EZ-BM, and RPE-BM were calculated from volumes and across nine ETDRS sectors. Manual segmentations were corrected by two masked expert graders and were compared using ICC. Dice coefficients (DC), Pearson correlation, and absolute thickness differences were used to assess agreement between automated and manual segmentation. Heat maps were generated to visualize thicknesses. Results: Thirty healthy eyes and thirty GA eyes were included in the analysis. Mean EZ–RPE, EZ–BM, and RPE–BM thicknesses were 47.55 ± 6.75 µm, 69.49 ± 6.92 µm, and 21.94 ± 3.46 µm, in the healthy eyes and 15.65 ± 11.09 µm, 39.18 ± 23.28 µm, and 23.52 ± 16.21 µm in GA eyes respectively. The model demonstrated high segmentation accuracy, with mean DC of 0.998 in healthy eyes and 0.995–0.998 in GA eyes. In healthy eyes, differences between automated and manual measurements were minimal (1.42 ± 3.39 μm (2.98%) for EZ–RPE, 1.31 ± 3.18 μm (1.88%) for EZ–BM, and 0.67 ± 1.71 μm (3.05%) for RPE–BM) which is within 1.88-3.05% from the gold standard (manual corrections), whereas GA eyes showed greater variability (mean differences of 3.61 ± 8.62 μm (23.06%) for EZ–RPE, 4.28 ± 11.34 μm (10.92%) for EZ–BM, and 4.4 ± 10.45 μm (18.71%) for RPE–BM). Heat maps revealed increased variability at the junctional zone surrounding atrophy. Automated and manual measurements showed strong correlations across all sectors in GA eyes (r = 0.97 for EZ–BM, 0.96 for EZ–RPE, and 0.89 for RPE–BM). Conclusions: The NMI-ORA enables accurate, automated segmentation and quantification of outer retinal layers, with performance comparable to expert graders.

3 June 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
AKAlice M. Kitay
Alice M. Kitay
JHJames V.M. Hanson
James V.M. Hanson
NHNasiq Hasan
Nasiq Hasan
MDMatthew Driban
Matthew Driban
Jay ChhablaniJay Chhablani
Jay Chhablani
MAMayss Al-Sheikh
Mayss Al-Sheikh
Purpose: To evaluate the impact of drusen-like deposits (DLD) on retinal layer integrity and retinal function by optical coherence tomography (OCT) and multifocal electroretinography (mfERG) in patients with systemic lupus erythematosus (SLE). Methods: We identified 66 eyes of 33 SLE patients treated with hydroxychloroquine (HCQ) that were categorized into two groups according to whether DLDs were present (34 eyes, Group One) or absent (32 eyes, Group Two). The groups were matched for age, sex, HCQ treatment duration, daily, and cumulative dosage. OCT (retinal layer thicknesses, central retinal thickness, CRT) and mfERG concentric ring analysis were analyzed and compared. Results: CRT was significantly thicker in Group One compared to Group Two (273.21 ± 3.96 vs. 254.5 ± 7.62) (p = 0.023). Group One also demonstrated an overall thicker retinal pigment epithelium compared to Group Two; however, the other outer retinal layers, outer nuclear layer, and photoreceptor layer were found to be significantly thinner in Group One compared to Group Two. We found no differences in mfERG parameters between the two groups. Conclusions: DLDs in SLE patients lead to abnormal central retinal layer thickness, which has no measurable impact on cone-mediated retinal function assessed by mfERG.

20 September 2021 in BMJ Case Reports
Verified
Journal Article
Open access
PDF file
NHNasiq Hasan
Nasiq Hasan
LRLional Raj
Lional Raj
DSDheepak M Sundar
Dheepak M Sundar
PKPrashant Kumar
Prashant Kumar