Wagner Wilson Ávila Bombardelli

Wagner Wilson Ávila Bombardelli

Auto-generated profile, based on publicly available information

Wagner Wilson Ávila Bombardelli

Ph.D. Student, Dept. of Biosystems Engineering, College of Agriculture “Luiz de Queiroz,” Univ. of São Paulo, Piracicaba, SP 13418-900, Brazil. ORCID:

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Journal of Irrigation and Drainage Engineering
Verified
Journal Article
Closed access
PDF file
RLRogério Lavanholi
Rogério Lavanholi
ACAntonio Pires Camargo
Antonio Pires Camargo
WBWagner Wilson Ávila Bombardelli
Wagner Wilson Ávila Bombardelli
JFJosé Antônio Frizzone
José Antônio Frizzone
NANassim Ait-Mouheb
Nassim Ait-Mouheb
Fabricio Correia de OliveiraFabricio Correia de Oliveira
Fabricio Correia de Oliveira
Emitters are important components of drip irrigation systems, and the use of labyrinths as a mechanism of energy dissipation stands out in the drippers’ design. Relating the geometric characteristics of labyrinths with their operational and hydraulic characteristics is not trivial and generally requires the use of computational simulation tools. This study developed and evaluated models that can predict the discharge of labyrinth channels as a function of their geometry to make possible the rapid prediction of pressure–discharge curves due to modifications in the labyrinth geometry. An empirical mathematical model was developed based on nonlinear regression, and a computational model was trained based on artificial neural networks (ANNs). Twenty-four designs of prototypes were built in polymethyl methacrylate to operate at a discharge of approximately 1.4  L h−1 under 100 kPa. The pressure–discharge curve of each prototype was determined in the laboratory in the range 50–350 kPa. Based on the experimental data, the coefficients of an empirical nonlinear model were fitted, and 11 single-hidden-layer ANN architectures were compared. The best accuracy was provided by an ANN architecture with an input layer with six neurons, six neurons in the hidden layer, and an output layer with a single neuron. The maximum relative errors of the predicted discharges were 9.5% and 9.4% for the ANN and nonlinear models, respectively. Both models were accurate and enabled rapid prediction of the emitter’s discharge. An open-source web application was developed to simulate the pressure–discharge curve of labyrinths within a range of geometric and operational characteristics.

1 January 2021 in Revista Brasileira de Engenharia Agrícola E Ambiental
Verified
Journal Article
Open access
PDF file
AAAna C. S. de Araujo
Ana C. S. de Araujo
JFJosé A. Frizzone
José A. Frizzone
ACAntonio Pires Camargo
Antonio Pires Camargo
DPDiego J. de S. Pereira
Diego J. de S. Pereira
VMVerônica G. M. L. de Melo
Verônica G. M. L. de Melo
WBWagner W. A. Bombardelli
Wagner W. A. Bombardelli
The objective of this study was to quantify the effect of water temperature variations on the discharge of collapsible thin-walled drip tapes with integrated non-pressure-compensating emitters. The tests were conducted in the laboratory using an automated test bench. Tests were performed to determine the discharge-pressure curves by varying the water temperature from 20 to 50 °C. Nine emitter models of three wall thicknesses (6, 8, and 9 MIL) were evaluated. The coefficients K and x of the discharge-pressure curves varied according to the water temperature. In flat emitters of turbulent flow (x < 0.5), the discharge decreased as the temperature increased. In the welded emitters of turbulent flow, several responses were observed. Regarding emitter D (x > 0.5), the discharge increased as the temperature was increased, while for emitter C (x < 0.5), the discharge decreased; the highest discharge variations occurred at pressures higher than 60 kPa. For embossed emitters, the discharge increased as a function of temperature, however, the greatest variation occurred at the lowest pressures. None of the emitters showed significant difference in the discharge variation due to wall thicknesses.

1 July 2019 in Revista Brasileira de Engenharia Agrícola E Ambiental
Verified
Journal Article
Open access
PDF file
WBWagner W. Á. Bombardelli
Wagner W. Á. Bombardelli
ACAntonio Pires Camargo
Antonio Pires Camargo
JFJosé A. Frizzone
José A. Frizzone
RLRogério Lavanholi
Rogério Lavanholi
HRHermes Soares Rocha
Hermes Soares Rocha
Information about local head loss caused by connections employed in micro-irrigation systems is hard to be found in literature. The objective of this research was to experimentally determine the local head losses in connections commonly used in micro-irrigation and propose mathematical models using the theorem of Buckingham. The methodology of tests was based on international standards. The tests were carried out under controlled inlet pressure, at 150 kPa, and five to ten units of each connection model were tested. The curves relating flow and head losses were drawn based on 15 flow conditions, obtained under increase and decrease of flow rate. For each condition, 30 points were collected resulting in a sample size of 900 points in each test. For each connection model evaluated, the following information was obtained: curves of local head loss as a function of flow rate and of local head loss coefficient (KL). The obtained values of KL ranged from 2.72 to 24.16, which become constant for Reynolds number higher than 10,000. The sensitivity of the coefficient related to a ratio of the internal sections in the connections was also verified. The flow exponents presented values close to the one applied by the Darcy-Weisbach equation (m = 2). The models developed for the connections presented a satisfactory performance.

1 May 2020 in Journal of Irrigation and Drainage Engineering
Verified
Journal Article
Closed access
LSLuiz Ricardo Sobenko
Luiz Ricardo Sobenko
WBWagner Wilson Ávila Bombardelli
Wagner Wilson Ávila Bombardelli
ACAntonio Pires Camargo
Antonio Pires Camargo
JFJosé Antonio Frizzone
José Antonio Frizzone
SDSergio Nascimento Duarte
Sergio Nascimento Duarte
In microirrigation systems, start connectors are used at lateral-manifold or microtube-lateral junctions, and minor losses occur when water flows through the start connectors. The connector’s geometry may cause contractions and/or expansions in the flow section, inducing local head losses that should be considered when designing irrigation subunits. The objective of this research was to analyze the experimental datasets available from previous studies in order to develop and validate mathematical models to estimate local head losses through start connectors using dimensional analysis and artificial neural networks. A dataset with 55,331 records of local head loss as a function of flow rate through several geometries of start connectors was evaluated. Four models based on dimensional analysis and artificial neural networks were developed and validated. The local head losses through start connectors depended on the fluid properties, operating hydraulic conditions, and geometric characteristics of the start connectors. For the full and simplified models based on dimensional analysis, 95% of discharge predictions had relative errors less than 13.0% and 14.3%, respectively. For the full and simplified models based on neural networks, 95% of discharge predictions had relative errors less than 12.2% and 12.7%, respectively. A web application was developed to facilitate the discharge predictions. Depending on the connector’s geometry, the minor losses through start connectors represent a significant percentage of the total head loss along the lateral.

2 October 2017 in Irriga
Verified
Journal Article
Open access
WBWagner Wilson Ávila Bombardelli
Wagner Wilson Ávila Bombardelli
ACAntonio Pires Camargo
Antonio Pires Camargo
RLRogério Lavanholi
Rogério Lavanholi
AAAna Cláudia Sátiro Araújo
Ana Cláudia Sátiro Araújo
MJMarcus Vinicius Talamini Junior
Marcus Vinicius Talamini Junior
JFJosé Antônio Frizzone
José Antônio Frizzone
PROJETO E VALIDAÇÃO DE UMA BANCADA PARA ENSAIOS DE PERDA DE CARGA LOCALIZADA WAGNER WILSON ÁVILA BOMBARDELLI¹; ANTONIO PIRES DE CAMARGO²; ROGÉRIO LAVANHOLI³; ANA CLAUDIA SÁTIRO ARAUJO¹; MARCUS VINICIUS TALAMINI JUNIOR¹ E JOSÉ ANTÔNIO FRIZZONE4 1 Mestrando, Departamento de Engenharia de Biossistemas, Escola Superior de Agricultura “Luiz de Queiroz” - ESALQ/USP, Avenida Pádua Dias, 11, 13418-900, Piracicaba - SP. E-mail: wavila@usp.br, satiroagro@gmail.com, talamini.1988@gmail.com ²Especialista em Laboratório, Departamento de Engenharia de Biossistemas - ESALQ/USP, e-mail: apc.pires@gmail.com ³ Doutorando, Departamento de Engenharia de Biossistemas – ESALQ/USP, e-mail rogeriolavanholi@usp.br 4 Prof. Dr. Titular, Departamento de Engenharia de Biossistemas – ESALQ/USP, e-mail: frizzone@usp.br 1 RESUMO As perdas de carga localizadas são relevantes principalmente no dimensionamento de subunidades de sistemas de microirrigação. O uso de sistemas automatizados adequadamente projetados e validados para a execução de ensaios é conveniente, pois assegura maior estabilidade das condições de ensaio, otimização do tempo de operação, redução das falhas ou imperfeições humanas, consequentemente conduzindo a melhor qualidade dos resultados de ensaio. Deste modo, o presente trabalho propôs projetar, instalar e validar uma bancada automatizada para condução de ensaios de perda localizada de carga. Desenvolveu-se o circuito eletrônico microcontrolado que dispõe de funcionalidades para aquisição e condicionamento de sinais de sensores; controle de inversor de frequência e válvula proporcional; controle Proporcional-Integral-Derivativo (PID); e, comunicação Modbus RTU com outros dispositivos através de rede RS-485. O firmware implementado no microcontrolador foi desenvolvido na linguagem C, enquanto que a interface gráfica do usuário (GUI) foi desenvolvida em C#. A validação da bancada foi efetuada a partir de ensaios de estabilidade, que permitem afirmar o adequado funcionamento da bancada de ensaios. Palavras-chave: circuito eletrônico microcontrolado, hidráulica, microirrigação W. W. Á. BOMBARDELLI; A. P. CAMARGO; R. LAVANHOLI; A. C. S. ARAUJO; M. V. TALAMINI JUNIOR; J. A. FRIZZONE DESIGN AND EVALUATION OF A TEST BENCH FOR DETERMINING MINOR PRESSURE LOSSES 2 ABSTRACT The minor pressure losses are fundamental in the development of subunits for micro-irrigation systems. The use of well-designed and validated automated systems in order to perform tests is convenient because it ensures a greater stability of test conditions, and also improves the use of operating time, reducing the risk of faults or human error, consequently, thus having better quality in the test results. Thereby, this paper aims to develop, install and validate an automated bench to conduct minor pressure loss tests. The previously developed micro-controlled electronic circuit has features to input and store signals from sensors; Frequency inverter controller and proportional valve; Proportional-Integral-Derivative Controller (PID); and a Modbus RTU communication protocol to interact with other devices via RS-485 network. The firmware implemented in the microcontroller was developed using the C programming language, whereas the graphical user interface (GUI) was programmed in C #. The validation of the bench was carried out using stability tests, which approved the test bench performance. Keywords: micro-controlled electronic circuit, hydraulic, micro-irrigation

1 August 2021 in Journal of Irrigation and Drainage Engineering
Verified
Journal Article
Closed access
PDF file
WBWagner W. A. Bombardelli
Wagner W. A. Bombardelli
ACAntonio P. Camargo
Antonio P. Camargo
LRLuiz H. A. Rodrigues
Luiz H. A. Rodrigues
JFJosé A. Frizzone
José A. Frizzone
The proper hydraulic design of microirrigation system subunits requires the characterization of minor losses. To this end, machine learning models based on artificial neural networks [multilayer perceptron (MLP)], support vector machines [support vector regression (SVR)], and an ensemble of decision trees [extreme gradient boosting (XGB)] were developed and validated to predict minor losses caused by fittings commonly used in microirrigation subunits. The databases for learning are collections of experiments with commercial fittings classified as I, Y, and T. The features considered were fluid properties along with geometric and operational characteristics. Semiempirical models based on dimensional analysis were less accurate than machine learning–based models. The MLP model presented the best performance for the evaluated processes, although it requires a considerable amount of data and an extensive calibration of the hyperparameters. The SVR model was predominantly more appropriate based on the radial basis function. However, it is computationally expensive, and the estimator may be more compromised by noise. The XGB model achieved the lowest computational cost and provided good accuracy with the test set but was less related to the theoretical power-law function expected in these hydraulic phenomena. An open-source web application was developed to support the use and comparison of the models; it can serve as an online tool for the design and simulation of minor losses.