The commercialization of mass hydrogen production via water electrolysis is presently limited by low operational current densities. The optimal performance of electrolysis cells is significantly influenced by the substantial formation and residence of bubbles at high current densities. Thus, it is crucial to design electrodes with the ability for rapid bubble discharge to ensure appropriate bubble management. However, the quantitative volumetric measurements required to determine the bubble discharge ability of an electrode are not yet sufficiently accurate. This paper describes a quantitative volumetric method that combines a stereoscopic shadowgraph imaging system with particle tracking velocimetry (PTV) to measure the three-dimensional position, size, and velocity of micrometer-sized bubbles. The proposed method successfully captures hydrogen bubbles larger than 30 μm bubbles in an alkaline water electrolyzer. Considering the different luminance patterns of small bubbles (r ≤ 4 pixels) and large bubbles (r > 4 pixels) in the current imaging system, a bubble-size adaptive detection algorithm is established based on the cascade correlation method to obtain the two-dimensional centroid coordinates and radius of the observed bubbles. The bubble size information is also introduced into a two-view PTV algorithm for retrieving the Lagrangian trajectory of each bubble. Both the bubble detection and PTV algorithms are validated using synthetic datasets. Once the bubble trajectories are resolved successfully, the three-dimensional bubble velocity is obtained, and the actual bubble sizes are further corrected using the depth information. Analysis of the trajectory and velocity components indicates the existence of lateral bubble motion, reflecting interactions among bubbles. The rise velocity is positively correlated with the bubble radius in two regions, respectively, and the deviation from the theoretical value reveals the influence of non-buoyancy factors. The proposed technique provides effective diagnostics of the three-dimensional dynamic characteristics of micrometer-sized bubbles and can be used to evaluate and design bubble management systems for various electrochemical energy conversion devices.
6 March 2025 in Measurement Science and Technology
The stereoscopic shadowgraph system can accommodate high framing rate, long depth of field, and high imaging quality for two-phase flow measurements. The system has been combined with three-dimensional particle tracking velocimetry (PTV) to implement time-resolved volumetric measurements. Due to inadequate constraints, the calibration residuals or system drift can cause deviation of mapping function, leading to a large proportion of ghost particles. In this study, the extrinsic parameters self-calibration (EPSC) based on particle images is introduced to correct the mapping function error. The algorithm is implemented by minimizing the reprojection disparity, where the drift is transferred to the right camera by fixing the left camera as reference. Synthetic dataset is used to evaluate the influence of drifts and self-calibration algorithm on PTV process within a wide range of 0.0039~0.0625 ppp particle image densities. The extrinsic parameters including both translational and rotational drifts are involved and the effect of sub-domains divisions under rotational drifts are discussed. Results indicate that the deviated mapping functions greatly impact the accuracy of 3D tracking process, and the EPSC algorithm can significantly reduce the disparity and the proportion of ghost particles. For translational drift between 0.57 and 1.13 pixels, more than 95% of true particles are tracked and the proportion of ghost particles is below 5% after EPSC process. For rotational drift with approximately a maximum 2 pixels disparity, the EPSC can also restore more than 95% and 55% true particles for the two datasets respectively. The current method is applied to the 3D flow field of an oscillating foil in still water, based on which reasonable particle trajectories are successfully resolved. The results indicate that the EPSC algorithm can effectively reduce the influence of system drift and improve the tracking accuracy of two-view PTV measurements. The current method has the potential to enable two-view volumetric PTV techniques to cope with scenarios of denser particle concentrations and achieve higher spatial resolution.
Changes are required on page 1 of the original published paper.1 The Chinese name of the fourth author is wrongly spelled as “闫晓辉” in the former manuscript. The
26 January 2026 in Measurement Science and Technology
The stereoscopic shadowgraph system holds great promise for transient three-dimensional (3D) measurement of complex flow fields, including two-phase flows and fluid-structure interactions, as it effectively avoids interfacial reflections. However, conventional two-view particle tracking algorithms often suffer from ghost particle generation caused by overlapping particles and failed cost function evaluations, negatively impacting tracking accuracy and downstream flow field analysis. To address these limitations, this study develops a novel particle tracking algorithm that integrates neighboring particle information to refine trajectory predictions and employs a skip-frame tracking strategy to improve stereo matching for low-velocity particles, thereby significantly enhancing the robustness of the overall tracking process. The algorithm introduces trajectory quality assessment and utilizes a relaxation-based matching probability algorithm to reduce candidate particle lists, which collectively enhance tracking reliability in complex and high-density flow environments. Validation using synthetic data from direct numerical simulations (DNS) demonstrates a notable reduction in ghost particle and vector detection rates at a particle density of 0.041 ppp (particles per pixel). The proposed approach was applied to the 3D measurement of the flow field induced by a low-aspect-ratio hydrofoil oscillating in still water. It successfully reconstructs 3D particle trajectories, accurately capturing flow field structures and mitigating the severe trajectory errors in the z-direction. The trajectories are interpolated onto a Cartesian grid to obtain the Eulerian velocity and vorticity fields, revealing the formation, evolution, and convection of coherent vortex structures during the hydrofoil's oscillation. Visual analysis using the Q criterion further confirms the presence of well-defined vortex rings, demonstrating the method's capability to resolve detailed and physically meaningful flow features. The methodology is generalizable and applicable to a broader range of dual-view imaging and particle tracking systems beyond shadowgraphy.