1 August 2019 in Indonesian Journal of Electrical Engineering and Computer Science
AOAbdulrahaman Okino Otuoze
Abdulrahaman Okino Otuoze
ISIbim Ebianga Sofimieari
+1
Electricity theft has caused huge losses over the globe and the trend of its perpetuation constantly evolve even as smart technologies such as smart meters are being deployed. Although the smart meters have come under some attacks, they provide sufficient data which can be analysed by an intelligent strategy for effective monitoring and detection of compromised situations. So many techniques have been employed but satisfactory result is yet to be obtained for a real-time detection of this electrical fraud. This work suggests a framework based on Universal Anomaly Detection (UAD) utilizing Lempel-Ziv universal compression algorithm, aimed at achieving a real-time detection in a smart grid environment. A number of the network parameters can be monitored to detect anomalies, but this framework monitors the energy consumption data, rate of change of the energy consumption data, its date stamp and time signatures. To classify the data based on normal and abnormal behaviour, Lempel-Ziv algorithm is used to assign probability of occurrence to the compressed data of the monitored parameters. This framework can learn normal behaviours of smart meter data and give alerts during any detected anomaly based on deviation from this probability. A forced aggressivemeasure is also suggested in the framework as means of applying fines to fraudulent customers.
1 December 2018 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Application of soft switching in DC-DC converter has achieved a remarkable success in power electronics technology in terms of reduction in switching losses, improve in power density, minimization of electromagnetic interference (EMI) and reduction in the volume of DC-DC converters. Quite a number of soft switching techniques had been reported in the past four decades. This paper aims at providing a review of various soft switching techniques, based on topology, the location of the resonant network, performance characteristics, and principles of operation. In addition, converters area of application, advantages as well as limitations are also highlighted.
30 June 2025 in IEEE Access
Multiple input non-isolated dc-dc converters remain very popular in applications involving hybrid energy integration. This is due to their compact structure and low cost in comparison with their isolated topologies counterparts. This paper proposed a high voltage gain high efficiency, soft-switching dual-input single-output dc-dc converter with low voltage stress for hybrid energy integration. The proposed converter achieves soft-switching for all the power switches at turn-on instants alongside high voltage conversion ratio. The coupled inductor is designed to facilitate ZVS and achieve high voltage gain eliminating the need for additional auxiliary circuits. This reduces the converter cost, number of components count and enhances efficiency. Furthermore, the voltage across the power switch is clamped with the help of an active clamp network. This facilitates the use of switches with low drain-to-source resistance (Rds on) hence reducing conduction losses and increasing the efficiency. Similarly, the operating modes of the converter as well as comparison with other similar converters are presented. In addition, experimental results obtained for 250 W prototype are presented which converts an input of 24 V dc to a 250 V dc at the output terminal with 97.8% efficiency.
1 May 2020 in Indonesian Journal of Electrical Engineering and Computer Science
In isolated type LLC resonant converters, transformer leakage inductances can be merged with the resonant inductor to extend the ZVS capability of the switches apart from isolation and voltage scaling. However, the transformer presents a resonant imbalance in the secondary side leading to secondary current unbalance, an increase in RMS value of the secondary current and increase thermal stress. This paper proposed a half-bridge non-isolated LLC resonant converter with a balanced rectifying current and stress in the rectifier diodes. The proposed converter can achieve the most advantages of isolated LLC converters, such as ZVS and low MOSFET turn-off loss. By the non-isolation method, secondary current and, transformer loss is significantly reduced. In addition, rectifier diodes operate with zero current switching and balanced rectifying current and stress over the entire operating range. The proposed non-isolated structure is verified by the experimental result with a 60W LLC resonant converter.
1 August 2020 in IET Power Electronics
This study proposed a novel non‐isolated half‐bridge Inductor‐Inductor‐Capacitor (HB LLC) resonant converter with automatic resonant frequency adjustment ability and a circulating current suppression auxiliary circuit. The proposed converter employs a hybrid modulation technique based on frequency modulation (FM) and pulse width modulation (PWM) to regulate the output voltage. At the nominal operating point, all the excellent attributes of a conventional LLC converter over the entire load range are maintained and output voltage control is achieved with FM. However, when the input voltage decreased to a level that LLC output voltage cannot be maintained with FM, the primary switches will operate at the minimum switching frequency and the auxiliary switch will be turned ON with PWM. The auxiliary switch is turned ON with zero‐voltage switching and automatically matching the circuit resonant frequency with the switching frequency for optimal operation. The effective resonant inductor is energised directly from the dc bus storing more energy which is later released to the load to achieving high gain while maintaining the desired output voltage with a narrow frequency span. In addition, the converter exhibits low circulating current under an enhanced gain condition. Experimental results are presented on a 60 W prototype to validate the theoretical prediction . The proposed converter has a peak efficiency of 97%.
8 September 2015 in International Journal of Intelligent Systems and Applications
Accurate control of servomotor in proper positioning of objects is of utmost importance in industrial applications. This paper presents the position control of dc servomotor using pole placement technique via Ackerman's formula. The mathematical model governing the dynamics of brush dc Pittman servomotor is developed and is then used to analyze which among the full state-feedback controller, feedback controller with feed-forward gain and integral controller with state feedback (SFB) will yield the best control performance. The steady state error, settling time and degree of overshoot are parameters on which the performance level is based. The whole simulation is validated using MATLAB/SIMULINK.