Xi Liu

Xi Liu

Auto-generated profile, based on publicly available information

Xi Liu

Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in International Journal of Surgery
Verified
Journal Article
Closed access
XLXi Liu
Xi Liu
HZHui Zhang
Hui Zhang
SCShiqiang Cen
Shiqiang Cen
FHFu-guo Huang
Fu-guo Huang
Though several systematic reviews concerned have been published, controversy still exists. The current systematic review was designed to clarify the detailed advantages and disadvantages of the negative pressure wound therapy (NPWT) in treatment of open fractures in comparison with the conventional wound dressings. A systematic search was performed in Pubmed, Cochrane Library, Embase, and Google Scholar for the published relevant clinical studies. Unpublished studies were searched in Clinicaltrials, ICTRP and ISRCTN. The outcome measures included presence of infection, wound healing process, length of the patient hospital stay, flap issues, frequency of amputation, and patient life quality. In the 8 randomized controlled trials (RCTs) (421 patients) and the 6 retrospective cohort studies (488 patients), NPWT resulted in a significantly lower infection rate, significantly shorter wound coverage time, wound healing time and hospital stay length, and the lower amputation rate. However, no statistically significant difference was found in the need for flap surgery, the proportion of free flaps, the flap failure rate or the fracture non-union rate. Only 1 RCT was reported to have a higher physical component score of short form 36 in the infected patients. NPWT can significantly reduce the risk of infection in treatment of open fractures and accelerate their wound healing process. Some but not much evidence suggests that NPWT may possibly help reduce the severity of the limb injury and therefore provide a chance for the limb to avoid amputation. Use of NPWT in the flap area is probably safe, but should be carried out with caution. The advantage of NPWT over the conventional wound dressings still requires to be confirmed in the other aspects.

1 January 2019 in The Journal of Foot and Ankle Surgery
Verified
Journal Article
Closed access
XLXi Liu
Xi Liu
HZHui Zhang
Hui Zhang
LLLei Liu
Lei Liu
YFYue Fang
Yue Fang
FHFuguo Huang
Fuguo Huang

2 August 2021 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
YLYaxing Li
Yaxing Li
YCYu Chen
Yu Chen
TGTingjiang Gan
Tingjiang Gan
BQBoquan Qin
Boquan Qin
XLXi Liu
Xi Liu
HZHui Zhang
Hui Zhang

13 November 2025 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
XMXi-Kun Ma
Xi-Kun Ma
BCBiao Cao
Biao Cao
XLXi Liu
Xi Liu
Responsive peptide hydrogels are advanced platforms for wound management because they can dynamically interact with the wound microenvironment. These smart materials respond to specific biochemical cues such as pH, reactive oxygen species (ROS), matrix metalloproteinases (MMPs), and glucose (Glu), enabling precise control over drug release, enhancement of cellular repair, and suppression of infection. By adapting to pathological conditions like elevated pH, persistent oxidative stress, and enzymatic imbalances, peptide hydrogels promote efficient healing in chronic wounds. Recent advances have expanded their responsiveness to include physical stimuli like temperature, light, and magnetic fields, broadening their applicability in deep and complex wound treatments. Despite promising outcomes, challenges remain in optimizing biocompatibility, biodegradability, and stimulus precision. Future efforts will focus on developing multifunctional and personalized hydrogel systems to achieve smarter, minimally invasive therapeutic strategies for wound care and beyond.

6 January 2020 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
WDWei Deng
Wei Deng
YLYaxing Li
Yaxing Li
SWShizhou Wu
Shizhou Wu
XLXi Liu
Xi Liu
FHFuguo Huang
Fuguo Huang
HZHui Zhang
Hui Zhang
Objective: This study aimed to evaluate the results of surgical treatment of tibial avulsion injuries of the posterior cruciate ligament (PCL) with a 3.5-mm locking compression hook plate (LCHP). Methods: From June 2012 to June 2015, 16 consecutive patients (10 males and 6 females, mean age: 38 (range: 19-57) years) presented with isolated tibial avulsion injuries of the PCL. We used a 3.5-mm LCHP and lag screws for open reduction and internal fixation (ORIF) through the posterior medial approach. The operation time, quantity of bleeding, visual analog scale (VAS) scores, stability of posterior drawer test (PDT) results, and fracture healing time were studied to assess clinical efficacy. At the 12-month follow-up, a functional evaluation using knee range of motion (ROM) and the Lysholm knee scoring system (LKSS) was performed. Results: The data from a mean follow-up of 24.1 (range: 14-33) months from 16 patients were recorded. No neurovascular complications, incision infections, or delayed union or nonunion were observed. The mean operation time was 61.4 (range: 45-80) min. The mean quantity of bleeding was 41.6 (range: 25-66) mL. The mean bone healing time was 11.8 (range: 45-80) weeks. The mean VAS score was 1.63 (range: 0-3) after surgery. The average LKSS and ROM of the knee were 51.75±7.67 and 50.94°±10.19° before surgery and 92.75±5.46 and 127.75°±6.13° at 1 year, respectively. The outcomes were judged to be excellent for 11 patients, good for 4, and fair for 1 (excellent and good rates: 93.8% for 15/16). At the final follow-up (≥1 year), the PDT scores returned to normal. Conclusion: The results showed that 3.5-mm LCHP provided reliable fixation following ORIF of isolated PCL tibial avulsion fractures and was a safe, simple, and effective procedure. This procedure may reduce complications and improve functional recovery relative to those of other procedures. Trial registration: Chinese Clinical Trial Registry, ChiCTR-1900022920. Registered on 3 May 2019. Level of Evidence: Level IV, Therapeutic study Cite this article as: Deng W, Li Y, Wu S, Liu X, Huang F, Zhang H. Surgical treatment of posterior cruciate ligament tibial avulsion fractures using a locking compression hook plate: A case series. Acta Orthop Traumatol Turc 2020; 54(6): 623-6.

18 August 2022 in International Journal of Ophthalmology
Verified
Journal Article
Open access
XWXing Wu
Xing Wu
XLXi Liu
Xi Liu
ZLZhaohui Li
Zhaohui Li
LDLiqin Deng
Liqin Deng
DCDaishi Chen
Daishi Chen
YWYing Wang
Ying Wang
To investigate the surgical outcomes of patients with chronic angle-closure glaucoma (CACG) treated with phacoemulsification (phaco)/endocyclophotocoagulation (ECP) with and without endoscopic goniosynechialysis (E-GSL). A retrospective, nonrandomized, comparative case series was conducted. Patients with CACG who underwent phaco in combination with either ECP alone (ECP group) or GSL with ECP (E-GSL group) from 2018 to 2019 were followed for 12mo and reviewed. Clinical features and outcomes were identified and analyzed. The ECP and E-GSL groups were matched in age and baseline intraocular pressure (IOP). Changes in IOP, mean of visual acuity (VA), peripheral anterior synechiae (PAS) formation, and the number of glaucoma medications was examined. The ECP group included 32 eyes of 27 patients, and the E-GSL group included 32 eyes of 26 patients. The preoperative baseline IOP was 22.18±6.48 mm Hg in the ECP group and 22.95±6.71 mm Hg in the E-GSL group (P=0.644). The mean IOP reduction was 26.2% in the ECP group and 41.6% in the E-GSL group at 12mo. The mean postoperative VA (logMAR units) at 12mo was 0.47 in the ECP group and 0.36 in the E-GSL group. The reduction in PAS formation and the number of glaucoma medications was also higher in the ECP group than E-GSL group at 12mo. The phaco/ECP and phaco/E-GSL groups both achieve a significant reduction in IOP without complications associated with traditional glaucoma filtration surgeries.