Military Medicine is AMSUS’ monthly peer-reviewed journal, with articles including scientific papers, case reports, and editorials. Its objective is to promote awareness of federal medicine by providing a forum for responsible discussion of common ideas and problems relevant to federal healthcare.
Hand-held transparent displays are important infrastructure for augmented reality applications. Truly transparent displays are not yet feasible in hand-held form, and a promising alternative is to simulate transparency by displaying the image the user would see if the display were not there. Previous simulated transparent displays have important limitations, such as being tethered to auxiliary workstations, requiring the user to wear obtrusive head-tracking devices, or lacking the depth acquisition support that is needed for an accurate transparency effect for close-range scenes.We describe a general simulated transparent display and three prototype implementations (P1, P2, and P3), which take advantage of emerging mobile devices and accessories. P1 uses an off-theshelf smartphone with built-in head-tracking support; P1 is compact and suitable for outdoor scenes, providing an accurate transparency effect for scene distances greater than 6m. P2 uses a tablet with a built-in depth camera; P2 is compact and suitable for short-distance indoor scenes, but the user has to hold the display in a fixed position. P3 uses a conventional tablet enhanced with on-board depth acquisition and head tracking accessories; P3 compensates for user head motion and provides accurate transparency even for closerange scenes. The prototypes are hand-held and self-contained, without the need of auxiliary workstations for computation.
This study assessed the reliability of pulse rate variability (PRV) from wrist worn photoplethysmography (PPG) as a substitute for heart rate variability (HRV) measured via electrocardiography (ECG), across tasks with varying loads and ambulation. Twenty-four healthy adults completed 13 sensorimotor tasks before and after a cognitive fatigue protocol. HRV and PRV were calculated using time domain metrics from filtered ECG and PPG signals. Results showed poor agreement between PRV and HRV in all tasks, with significant differences in 11 of 13 conditions. These findings highlight the limitations of PRV from wrist worn devices as a substitute for ECG based HRV in real world assessments of cardiac variability. Future work should focus on better noise reduction techniques, improved sensor placement, and longer recordings to support spectral analysis, as well as larger sample sizes to clarify when PRV can reliably approximate HRV.