Chenyang Wang

Chenyang Wang

Auto-generated profile, based on publicly available information

Chenyang Wang

Chongqing Univ. (China)

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2021 in AWWA Water Science
Verified
Journal Article
Open access
PDF file
CWChenyang Wang
Chenyang Wang
BYBei Yan
Bei Yan
GMGabriel Munoz
Gabriel Munoz
Sébastien SauvéSébastien Sauvé
Sébastien Sauvé
JLJinxia Liu
Jinxia Liu
Technologies applicable at a field scale to mitigate soil and groundwater pollution by per‐ and polyfluoroalkyl substances (PFAS) due to the release of aqueous film‐forming foams are urgently needed. We demonstrate that modified bentonite clays as soil amendments can effectively reduce the leaching of PFAS from impacted soils. In batch experiments, the significant decrease (95%–99%) of leachable anionic PFAS, including perfluorooctane sulfonate, perfluorohexane sulfonate, and perfluorooctane carboxylate, was achieved in 1–4 days at a clay dosage as low as 0.5% w/w. A significant decline of leachable cationic and zwitterionic PFAS (70%–99%) was also observed. The clays performed the best in immobilizing PFAS anions, while granular activated carbon was effective in preventing PFAS cation leaching. Hardwood biochar had minor or negligible effects on any PFAS. The study provides strong evidence to support using modified clays as part of mitigation or remediation strategies to prevent PFAS from mobilizing on a field scale.Article Impact Statement: The study demonstrated that modified bentonite clays effectively immobilize various PFAS in AFFF‐contaminated soils to prevent leaching.

13 May 2022
Verified
Conference Paper
Closed access
PDF file
XMXiao Ma
Xiao Ma
CWChenyang Wang
Chenyang Wang
WYWei Yu
Wei Yu
Formaldehyde electrochemical sensors are arranged on side walls, ceilings, etc, which can't effectively reflect the concentration level of formaldehyde, so the ventilation system can't respond in time or respond too fast, resulting in the ineffective removal. In this study, we set up an experimental room to monitor the formaldehyde in different locations under different working conditions, then linearly fit the detected concentration to the target concentration. With the same working conditions' average correction coefficients, correcting the actual point monitoring data. The results show that the average error of the monitoring data after the correction is reduced by 46-71%. This method is easy to operate and has certain reference significance for the sensor setting in actual engineering.