Objectives Does phaco–ECP reduce intraocular pressure? Is phaco–ECP safe? Design Retrospective case note review of all patients undergoing phaco–ECP between June 2008 and June 2009. All glaucoma subtypes were included. Setting Single District General Hospital Ophthalmology Department within the UK. Participants 58 participants case notes reviewed. Mean age 79.0 years (SD ±9.8). Interventions All patients received combined cataract surgery and endoscopic cyclophotocoagulation. Outcome measures Follow-up was 1 day, 1 week, 1, 3, 6, 12, 18 and 24 months for intraocular pressure (IOP) measurement. Number of medications, visual acuity and presence of complications were also assessed. Results Of the 58 cases performed, 56 case notes (97%) were available for analysis. Mean age 79.0 years (SD ±9.8). Mean pre-procedural IOP was 21.54 mm Hg (95% CI 19.86 to 23.22, n=56). Mean IOP was 14.43 mm Hg (95% CI 13.65 to 15.21, n=53) at 18 months and 14.44 mm Hg (95% CI 13.63 to 15.25, n=41) at 24 months. The mean drop from baseline to 18 and 24 months was 7.1 mm Hg. Statistically significant decrease in IOP was demonstrated at all time points (p<0.001). Mean medication usage was 1.97 agents (95% CI 1.69 to 2.25) at baseline, 1.96 agents (95% CI 1.70 to 2.22) at 18 months and 2.07 agents (95% CI 1.76 to 2.38) at 24 months. No statistically significant change throughout. Conclusions This study confirms the safety of phaco–ECP. In this case series, the IOP-lowering effect was significant at all time points; however, the effect of cataract surgery alone was not controlled. A randomised controlled trial is required to draw efficacy conclusions. The authors proposed endoscopic cyclophotocoagulation's main role is to optimise control of low-risk glaucoma of low-risk patients at the time of cataract surgery. However, the authors do not propose that phaco–ECP is a substitute for filtration surgery in high-risk eyes or when low target pressures (<14 mm Hg) are indicated.
Objective To report the 12-month outcomes of the dexamethasone intravitreal implant in retinal vein occlusion (RVO), using an as-needed repeat injection protocol. Design Retrospective consecutive case series of 51 eyes of 49 patients with macular oedema as a result of RVO that received an intravitreal dexamethasone implant and were followed up for at least 12 months. Results 70% of patients responded to dexamethasone implant injection with an improvement in visual acuity (VA) and macular oedema within 3 months of injection, but only 30% of eyes gained ≥15 letters. The mean change in VA letter score at 12 months compared with baseline for branch RVO (BRVO) and central RVO (CRVO) was 5.7±2.3 and 11.5±11.0 EDTRS letters, respectively. 56% of patients relapsed, with the median time to relapse being 17 weeks for patients with branch RVO and 18 weeks for patients with CRVO. Repeat injections achieved similar VA gains, but the duration of effect of repeat dexamethasone implants was much shorter at 10 weeks. 14 eyes (27%) developed a significant rise in intraocular pressure, and three of these required treatment with oral acetazolamide. Four eyes with CRVO developed neovascular glaucoma during the study. Conclusions The intravitreal dexamethasone implant does not last the 6 months implied by the retreatment protocol in the GENEVA trial, and improved results can be achieved with an as-needed retreatment protocol, particularly in CRVO. However, visual outcomes remain similar to those previously seen with triamcinolone in the SCORE study and neovascular complications remain a feature of CRVO.
Surgical management of glaucoma offers a means of effective disease control. A gel stent that facilitates drainage to the subconjunctival space offers intraocular pressure (IOP) reduction similar to traditional glaucoma filtering surgeries in a less invasive manner. However, like all subconjunctival filtering procedures that result in a bleb, fibrosis can present as a cause of elevated IOP. The following proposed techniques and recommendations for managing elevated IOP due to bleb fibrosis after gel stent implantation are based on the clinical experience of the authors. The goal of this paper is to improve outcomes following gel stent surgery by providing guidance on assessment of bleb function and strategies for bleb enhancement.
Background Glaucoma services are under unprecedented strain. The UK Healthcare Safety Investigation Branch recently called for new ways to identify glaucoma patients most at risk of developing sight loss, and of filtering-out false-positive referrals. Here, we evaluate the feasibility of one such technology, Eyecatcher: a free, tablet-based ‘triage’ perimeter, designed to be used unsupervised in clinic waiting areas. Eyecatcher does not require a button or headrest: patients are simply required to look at fixed-luminance dots as they appear. Methods Seventy-seven people were tested twice using Eyecatcher (one eye only) while waiting for a routine appointment in a UK glaucoma clinic. The sample included individuals with an established diagnosis of glaucoma, and false-positive new referrals (no visual field or optic nerve abnormalities). No attempts were made to control the testing environment. Patients wore their own glasses and received minimal task instruction. Results Eyecatcher was fast (median: 2.5 min), produced results in good agreement with standard automated perimetry (SAP), and was rated as more enjoyable, less tiring and easier to perform than SAP (all p<0.001). It exhibited good separation (area under receiver operating characteristic=0.97) between eyes with advanced field loss (mean deviation (MD) < −6 dB) and those within normal limits (MD > −2 dB). And it was able to flag two thirds of false-positive referrals as functionally normal. However, eight people (10%) failed to complete the test twice, and reasons for this limitation are discussed. Conclusions Tablet-based eye-movement perimetry could potentially provide a pragmatic way of triaging busy glaucoma clinics (ie, flagging high-risk patients and possible false-positive referrals).