Benjamen P. Reed

Benjamen P. Reed

Auto-generated profile, based on publicly available information

Benjamen P. Reed

National Physical Laboratory Teddington UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2025 in Surface and Interface Analysis
Verified
Journal Article
Open access
GKGwilherm Kerherve
Gwilherm Kerherve
WSWilliam S. J. Skinner
William S. J. Skinner
JHJulian A. Hochhaus
Julian A. Hochhaus
AGArthur Graf
Arthur Graf
DMDavid Morgan
David Morgan
DPDavid J. Payne
David J. Payne
KherveFitting is a software written in Python and designed for fitting X‐ray photoelectron spectroscopy (XPS) data. It provides a user‐friendly graphical interface for researchers in materials science and surface analysis, offering features that include multiple background subtraction methods, various peak fitting models, and automated multipeak fitting with customisable constraints. This software aims to fill a gap in the market for XPS analysis tools, providing a freely available solution for users. This paper describes the software architecture and its theoretical background, including fitting algorithms and peak models. Its performance is validated by directly comparing quantification accuracy and peak fitting capabilities against established commercial software packages, demonstrating robust and reliable results across diverse test cases including ionic liquids, conducting oxides, and rare earth materials.

23 November 2020 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
BRBenjamen P. Reed
Benjamen P. Reed
DCDavid J. H. Cant
David J. H. Cant
SSSteve J. Spencer
Steve J. Spencer
ACAbraham Jorge Carmona-Carmona
Abraham Jorge Carmona-Carmona
ABAdam Bushell
Adam Bushell
ASAlexander G. Shard
Alexander G. Shard
We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

27 April 2023 in Carbon
Verified
Journal Article
Closed access
BRBenjamen P. Reed
Benjamen P. Reed
SMSofia Marchesini
Sofia Marchesini
GCGiovanni Chemello
Giovanni Chemello
DMDavid Morgan
David Morgan
NVNeil Vyas
Neil Vyas
APAndrew J. Pollard
Andrew J. Pollard

1 October 2020 in Carbon
Verified
Journal Article
Closed access
SMSofia Marchesini
Sofia Marchesini
PTPiers Turner
Piers Turner
KPKeith R. Paton
Keith R. Paton
BRBenjamen P. Reed
Benjamen P. Reed
BBBarry Brennan
Barry Brennan
APAndrew J. Pollard
Andrew J. Pollard

18 May 2022 in Physical Review B
Verified
Journal Article
Closed access
PDF file
BRB. P. Reed
B. P. Reed
MBMarianne Etzelmüller Bathen
Marianne Etzelmüller Bathen
JAJ. W. R. Ash
J. W. R. Ash
CMC. J. Meara
C. J. Meara
AZA. A. Zakharov
A. A. Zakharov
SCS. P. Cooil
S. P. Cooil
The evolution of the diamond (111) surface as it undergoes reconstruction and subsequent graphene formation is investigated with angle-resolved photoemission spectroscopy, low energy electron diffraction, and complementary density functional theory calculations. The process is examined starting at the C(111)−(2×1) surface reconstruction that occurs following detachment of the surface adatoms at 920 ∘C, and continues through to the liberation of the reconstructed surface atoms into a freestanding monolayer of epitaxial graphene at temperatures above 1000 ∘C. Our results show that the C(111)−(2×1) surface is metallic as it has electronic states that intersect the Fermi level. This is in strong agreement with a symmetrically π-bonded chain model and should contribute to resolving the controversies that exist in the literature surrounding the electronic nature of this surface. The graphene formed at higher temperatures exists above a newly formed C(111)−(2×1) surface and appears to have little substrate interaction as the Dirac point is observed at the Fermi level. Finally, we demonstrate that it is possible to hydrogen-terminate the underlying diamond surface by means of plasma processing without removing the graphene layer, forming a graphene-semiconductor interface. This could have particular relevance for doping the graphene formed on the diamond (111) surface via tuneable substrate interactions as a result of changing the terminating species at the diamond-graphene interface by plasma processing.

23 November 2020 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
ASAlexander G. Shard
Alexander G. Shard
BRBenjamen P. Reed
Benjamen P. Reed
This paper extends a previous description of XPS survey spectra from low density polyethylene (LDPE), which was specific for a single type of geometry, to all geometries. Instrument geometries are specified by two angles. The first angle, a, is between the sample-to-monochromator vector and the sample-to-analyzer vector. The second angle, b, is the dihedral angle between the anode-monochromator-sample plane and the monochromator-sample-analyzer plane. The second angle is important because of the polarization induced by the monochromator. We show, using theory, that the XPS spectrum can be decomposed into a “magic angle” reference spectrum, I1, and an anisotropy correction spectrum, f. The geometry for LDPE at which photoemission intensity is equivalent to isotropic emission is shown to be a function of a and b with extreme values for a of 64.6° (b = 0 or 180°) and 57.5° (b = 90°). The deviation of these angles from the “magic angle” a = 54.7° is due to a combination of x-ray polarization and nondipole effects in photoemission. Intensity-calibrated data from a number of instruments with two geometries with b = 180°, one set with a = 60° and the other set with a = 45° are used to determine I1 and f, and these are fitted with simple functions to allow the reproduction of LDPE reference spectra for any instrument geometry. The spectra are taken from the Versailles Project on Advanced Materials and Standards, Technical Working Area 2: Surface Chemical Analysis study A27 and are traceable to the National Physical Laboratory, UK intensity calibration spectra for argon ion sputter-cleaned gold. The functions in this paper may be used in the calibration of XPS instruments with quartz-crystal-monochromated Al Kα x-rays by the comparison of the calculated reference spectrum to data from clean LDPE.