1 May 2013 in Journal of X-Ray Science and Technology
In recent years, the total variation (TV) minimization method has been widely used for compressed sensing (CS) based CT image reconstruction. In this paper, we propose a few-view reweighted sparsity hunting (FRESH) method for CT image reconstruction, and demonstrate the superior performance of this method. Specifically, the key of the purposed method is that a reweighted total variation (RwTV) measure is used to characterize image sparsity in the cost function, outperforming the conventional TV counterpart. To solve the RwTV minimization problem efficiently, the Split-Bregman method and other state-of-the-art L1 optimization methods are compared. Inspired by the fast iterative shrinkage/thresholding algorithm (FISTA), a predication step is incorporated for fast computation in the Split-Bregman framework. Extensive numerical experiments have shown that our FRESH approach performs significantly better than competing algorithms in terms of image quality and convergence speed for few-view CT. High-quality images were reconstructed by our FRESH method after 250 iterations using only 15 few-view projections of the Forbild head phantom while other competitors needed more than 800 iterations. Remarkable improvements in details in the experimental evaluation using actual sheep thorax data further indicate the potential real-world application of the FRESH method.
15 July 2022 in Physica Medica
4 February 2019 in Scientific Reports
Prompt gamma ray (PG) imaging based on Compton camera (CC) is promising to realize in vivo verification during the proton therapy. However, the finite spatial and energy resolution of current CC, as well as the Doppler broaden effect, degrade the quality and resolution of PG images. In addition, due to the inherent geometrical complexity of Compton camera data, PG imaging can be time-consuming and difficult to reconstruct in real-time, while using standard techniques such as filtered back-projection or maximum likelihood-expectation maximization. In this paper, we propose three modifications of origin ensembles with resolution recovery (OE-RR) algorithm based on Markov chains to accelerate the convergence to equilibrium of OE-RR algorithm and improve the image quality. For evaluation, we performed a Monte Carlo simulation of a three-stage CZT Compton camera with resolution loss to detect the PG produced by a proton beam in a water phantom, and evaluate image quality of the gamma rays emitted during proton irradiation. The results show that our ordered OE-RR algorithm realized a good resolution recovery and accurate estimation of the position, including the peak and the distal falloff of the PG emission with remarkably faster reconstruction, thus demonstrating the feasibility of this new method in non-idealized PG-based proton range verification.
3 December 2014 in Optics Express
The finite focal spot is one of the major limitations of the high spatial resolution CT, especially to the high-energy industrial CT system with a macro-focus x-ray source. In this paper, we propose an efficient reconstruction framework through finite focal spot size based projection modeling to improve the spatial resolution of current industrial CT system, and demonstrate the superior performance of this method. First of all, the blurred projection produced by a finite size source is modeled as the integral ideal projection of a given point source over the finite focal spot support. Under the model discretization, the approximate linear equivalence relation between the actual finite focus model and the ideal point source model is established. Then a projection recovery method with this relationship is presented to recover the projection of the finer focal spot from the blurred projection. Finally, a high-spatial resolution image can be reconstructed from the recovered projections using the standard Filtered Back-Projection (FBP) algorithm. Furthermore the noise in the reconstructed image with different model parameters is studied and a difference image based fusion method is presented for the further suppression of the noise caused by the projection analysis processing. Both numerical simulations and real experiments have shown that the proposed reconstruction framework with the outstanding performance and efficiency characteristics can significantly enhance the spatial resolutions of current high-energy industrial CT systems.