Recently, the use of type I collagen obtained from Nile Tilapia (Oreochromis niloticus) was proposed for the treatment of second and third-degree burning lesions and diabetic ulcers due to its occlusive and healing properties. The aim of this report is to describe the use of Nile tilapia skin as an occlusive barrier to protect palatal wounds after the removal of free autogenous soft tissue grafts. Two patients with a deficiency in the height of keratinized mucosa were indicated for treatment with free gingival grafts. The palatal donor area was covered with a Nile tilapia skin, stabilized by sutures. Seven days after surgery, patients returned for post-operative care. Patients’ reported outcomes were investigated by the use of a visual analogue scale and included pain, discomfort, impact on chewing and speaking. Analgesics consumption was also recorded. Standardized photographs were obtained to monitor wound healing. Patients were followed up for 30 days. Patients reported reduced pain levels, with low consumption of analgesics during the first week after surgery. No discomfort or difficulty in chewing or speaking was reported. No complications such as hemorrhage or edema were observed. These findings suggest that the Nile Tilapia skin may be an interesting alternative as an occlusive biological dressing in palatal wounds harvest of free gingival grafts.
Gingival recessions are a highly prevalent issue that is often associated with interproximal tissue deficiency. An intervention in these scenarios is of extreme importance since these defects can l...
The lack of cementum in peri-implant tissues leads to a deficiency in anchorage points for gingival collagen fibers. This arrangement is linked to reduced protective capabilities compared to teeth. Therefore, there is a pressing need to develop surfaces that optimize the interaction between soft tissue and implants. 3D-printed titanium disks (Ti3DP), machined disks (TiMC), and glass coverslips (GS) were seeded with human gingival fibroblasts. These specimens underwent mechanical characterization via roughness and wettability assays. Biological characterization included assessments of cellular viability (live/dead), adhesion and spreading (F-actin), cell count (DAPI), cellular metabolism (Alamar blue), adhesive strength, and soluble collagen and total protein quantification up to 14 days. Data analysis employed Student’s t-test and ANOVA post-hoc Tukey test (α = 0.05). The group TiMC exhibited higher hydrophilicity and lower roughness compared to Ti3DP. All groups demonstrated cellular viability throughout the study period. Adhesive strength did not significantly differ among groups; however, cell count was higher in TiMC and GS after one day of cell seeding in comparison to Ti3DP. Morphologically, GS and TiMC displayed more fusiform cells with a uniform distribution, while Ti3DP showed smaller, irregular cells with multiple lamellipodia and filopodia. Additionally, statistically superior collagen and total protein deposition was observed in Ti3DP (p < 0.01). The 3D-printed titanium surface allowed human gingival fibroblasts to adhere to it, leading to a 3D cytoskeleton morphology that culminated in increased collagen expression. Therefore, these 3D-printed devices present a promising avenue for producing transmucosal components due to their increase in collagen production.
1 January 2024 in Dental Press Journal of Orthodontics
Objective: This study evaluated the accuracy and precision of digital models acquisition using a home-built, low-cost scanning system based on the structured light method. Methods: a plaster model (PM) was scanned using the experimental device (SL) and a dental desktop scanner (DS). The teeth dimensions of PM and SL models were measured in triplicate, with a caliper and digitally, respectively. The agreement of the measurements of each model was evaluated using the intraclass correlation coefficient, and the validity between the different measurement techniques was assessed using the Bland-Altman analysis. The accuracy and precision of the models were qualitatively investigated using the mesh superposition of the SL and DS models. Results: A high intraclass correlation coefficient was observed in all models (PM=0.964; SL1=0.998; SL2=0.995; SL3=0.998), and there was no statistical difference between the measurements of the SL models (p>0.05). PM and SL model measurements were found to be in good agreement, with only 3.57% of the observed differences between the same measurement being located outside 95% limits of agreement according to Bland and Altman (0.43 and -0.40 mm). In the superimpositions of SL-SL and SL-DS models, areas of discrepancy greater than 0.5 mm were observed mainly in interproximal, occlusal, and cervical sites. Conclusion: These results indicate that the home-built SL scanning system did not possess sufficient accuracy and precision for many clinical applications. However, the consistency in preserving the dental proportions suggests that the equipment can be used for planning, storage, and simple clinical purposes.
A utilização de implantes dentários tem sido cada vez mais uma escolha por parte dos pacientes. Na busca pela reabilitação unitária ou de todos os elementos dentários, os implantes osseointegrados possuem inúmeros benefícios para o restabelecimento da função, estética, fonética e conforto ao paciente. O objetivo dessa revisão de literatura é abordar a importância dos cuidados pré-operatórios que o Implantodontista deve realizar previamente a instalação dos implantes. Para isso, foi realizada uma busca de estudos nas bases de dados Scielo, Lilacs, PubMed e Science Direct. com os descritores “dental implants and installation”, “dental implants and complementary exams” com “and” e “or” como ferramentas integrativas de busca. Observa-se diversos estudos abordandos o comprometimento da taxa de sobrevivência e de sucesso de implantes dentários em pacientes com alguma alteração sistêmica. Quando presente essas alterações, o risco de falhas e complicações são maiores, porém a partir de um adequado exame físico e auxiliados por exames complemetares, é possível mimetizar riscos ao paciente e promover mais sobrevida ao implante. Deve se ressaltar que o tratamento com implantes dentais é um procedimento controlado, seguro e confiável, inclusive na reabilitação dos pacientes idosos. Portanto, cabe ao Implantodontodontista possuir conhecimento para saber avaliar integralmente adequadamente o paciente que será submetido a cirurgia de instalação de implantes.