1 September 2020 in NAR Genomics and Bioinformatics
Detection of copy number variations (CNVs) is essential for uncovering genetic factors underlying human diseases. However, CNV detection by current methods is prone to error, and precisely identifying CNVs from paired-end whole genome sequencing (WGS) data is still challenging. Here, we present a framework, CNV-JACG, for Judging the Accuracy of CNVs and Genotyping using paired-end WGS data. CNV-JACG is based on a random forest model trained on 21 distinctive features characterizing the CNV region and its breakpoints. Using the data from the 1000 Genomes Project, Genome in a Bottle Consortium, the Human Genome Structural Variation Consortium and in-house technical replicates, we show that CNV-JACG has superior sensitivity over the latest genotyping method, SV2, particularly for the small CNVs (≤1 kb). We also demonstrate that CNV-JACG outperforms SV2 in terms of Mendelian inconsistency in trios and concordance between technical replicates. Our study suggests that CNV-JACG would be a useful tool in assessing the accuracy of CNVs to meet the ever-growing needs for uncovering the missing heritability linked to CNVs.
24 September 2021 in Acta Biomaterialia
4 September 2024 in The Laryngoscope
26 February 2025 in Drug Delivery and Translational Research
25 June 2021 in Otology & Neurotology
Background: Otologic surgery in guinea pig requires head immobilization for microscopic manipulation. Existing commercially available stereotaxic frames are expensive and impede access to the ear as they rely on ear bars or mouthpieces to secure the head. Method: Prototype head holders were designed using the Solidworks 2019 software and 3D-printed using Formlabs Form 2 Printers with photopolymer resin. The head holder consists of a C-shaped brace with adjustable radial inserts of 1/4-20 UNC standard screws with cone point tips providing head fixation for animals of various sizes. The C-shaped brace is attached to a rod that can be secured to a commercially available micromanipulator. The head holder design was tested during in vivo guinea pig experiments where their head motion with (n = 22) and without the head holder (n = 2) was evaluated visually through a stereotaxic microscope at 24× magnification during surgery. Results: The head holder design was easy to use and allowed for both nose cone administration of anesthesia and access to the ear for intraoperative auditory testing and manipulation. Functionally, the head holder successfully minimized head movement. Furthermore, harvested round window membranes evaluated at 72 hours following surgery showed precise perforations with the use of head holder. Conclusion: The novel 3D-printed head holder enables simultaneous access for nose cone administration of anesthesia and surgical manipulation of the ear and brain. Moreover, it provides a modular, intuitive, and economical alternative to commercial stereotaxic devices for minimizing head motion during small animal surgery.
25 January 2005 in International Journal of Modern Physics B