Anna Murray

Anna Murray

Auto-generated profile, based on publicly available information

Anna Murray

Affiliation The Aquaya Institute, San Anselmo, California, United States of America

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2024 in Water Resources Research
Verified
Journal Article
Open access
AMAnna L. Murray
Anna L. Murray
GSGabriela Stone
Gabriela Stone
AYAudrey R. Yang
Audrey R. Yang
NLNicholas F. Lawrence
Nicholas F. Lawrence
HMHannah Matthews
Hannah Matthews
GKGeorgia L. Kayser
Georgia L. Kayser
Sustained functionality of rural water systems is a global challenge. Research on factors contributing to rural water system functionality is largely restricted to hand pumps from single geographies. We analyzed monitoring data from 10 drinking water supply programs in nine sub‐Saharan African and South Asian countries collected between 2017 and 2020. Data included 1,805 randomly selected water points (tap stands, spring protections, rainwater collection, and boreholes and hand‐dug wells with hand pumps) from two cross‐sectional samples: older construction (1–12 years old) and new construction (<1 year). Data collection included observations of water point functionality (“water available”) and management committee questionnaires. Overall, 79% of older construction and 92% of new construction water points were functional. In a mixed effects logistic regression to identify factors contributing to functionality within the older construction sample, piped water tap stands had lower odds of functioning than boreholes with hand pumps (OR = 0.26, 95% CI:0.15–0.46). Water points in communities with fewer available water points, those with operational water management committees (which meet often, collect fees, and can name someone for maintenance), and those with financial savings were associated with higher functionality. As piped water system provision increases in line with international development goals, our results suggest that the benefits of providing higher levels of water service should be carefully considered alongside the technological, institutional, and financial investment required to operate and maintain more complex piped water systems in rural settings.

30 April 2015 in Journal of Water, Sanitation and Hygiene for Development
Verified
Journal Article
Open access
PDF file
AMAnna Murray
Anna Murray
MGMario Goeb
Mario Goeb
BSBarbara Stewart
Barbara Stewart
CHCatherine Hopper
Catherine Hopper
JPJamin Peck
Jamin Peck
DLDaniele Lantagne
Daniele Lantagne
The Sawyer PointOne hollow fiber membrane microfilter is promoted for household water treatment in developing countries. Critical limitations of membrane filtration are reversible and irreversible membrane fouling, managed by backwashing and chemical cleaning, respectively. The PointOne advertised lifespan is 10 years; users are instructed to backwash as maintenance. Owing to reduced turbidity and bacterial removal efficiencies, six PointOnes were removed from Honduran homes after 23 months of use. In the laboratory, we tested sterile water filtrate for turbidity and bacterial presence before and after backwashing and chemical cleaning. Sterile water filtrate from uncleaned filters had turbidity of 144–200 NTU and bacteria counts of 13–200 CFU. Cleaned filter effluent was positive for total coliforms. On one new and one used, cleaned filter, we imaged membranes with scanning electron microscopy and characterized surface elemental compositions with spectroscopy. Images and spectroscopy of the used, cleaned membrane revealed a dense, cake fouling layer consisting of inorganic metal oxides, organic material, and biofouling. Burst fibers were visually observed. This PointOne was thus irreversibly fouled and non-functional after <2 years of use. Further research is recommended to determine: impacts of source water quality on PointOne performance, a cleaning regimen to manage fouling, and an appropriate filter lifespan.

20 May 2021 in Membranes
Verified
Journal Article
Open access
PDF file
CHCamille Heylen
Camille Heylen
AAAlice Oliveira Aguiar
Alice Oliveira Aguiar
GSGabrielle String
Gabrielle String
MDMarta Domini
Marta Domini
NGNathaniel Goff
Nathaniel Goff
DLDaniele Lantagne
Daniele Lantagne
Hollow-fiber membrane filters (HFMFs) for household water treatment (HWT) can efficaciously remove disease-causing organisms in laboratory settings. However, lower effectiveness in use in low- and middle-income countries (LMICs) and humanitarian contexts (HCs) has been observed and attributed to membrane fouling and the associated cleaning. In LMICs/HCs, it is not possible to prevent and control fouling using commonly known methods (e.g., testing influent water, maintenance regimes), and the literature on fouling/cleaning of HFMFs distributed in LMICs is scarce. As such, controlled laboratory experiments were conducted to determine the efficacy of locally available (in LMICs/HCs) backwashing solutions at removing fouling using different influent waters and HFMF types. Four commonly distributed HFMFs were selected; fouling layers were developed by filtering three influent water compositions, representing LMIC/HC waters, for 10-days, and bleach, water, or vinegar backwashing solutions were used for daily backwashing. Filter performance indicators included: fiber mechanical properties (strain at break, break force), water quantity performance (flow), water quality performance (turbidity, E. coli), and imaging. The study found fouling developed rapidly and altered mechanical properties and water quantity indicators within 200 h of filtration. Fouling did not decrease water quality indicators. Backwashing improved the filter’s mechanical properties and water quantity performance, but it did not fully recover the initial performance. Additionally, recovery differed between backwashing solutions, and no universal cleaning recommendation appropriate for HFMFs in LMICs/HCs was identified. Overall, fouling development and control depended on HFMF type, influent water quality, and backwashing solution type; thus, caution before distributing HFMFs for long-term use in LMICs/HCs is recommended.

6 February 2026 in PLOS Water
Verified
Journal Article
Open access
PDF file
JRJennifer Hoponick Redmon
Jennifer Hoponick Redmon
ASAaron Salzberg
Aaron Salzberg
JFJennifer De France
Jennifer De France
JTJorge Alvarez-Sala Torreano
Jorge Alvarez-Sala Torreano
AMAnna Murray
Anna Murray
CLChristopher Lindsay
Christopher Lindsay