Leila Payaminia

Leila Payaminia

Auto-generated profile, based on publicly available information

Leila Payaminia

Department of Prosthodontics, Faculty of Dentistry, Dental Implant Research Center Tehran University of Medical Sciences Tehran Iran

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Heliyon
Verified
Journal Article
Open access
LPLeila Payaminia
Leila Payaminia
NMNaeime Moslemian
Naeime Moslemian
SYShima Younespour
Shima Younespour
SKSoudabeh Koulivand
Soudabeh Koulivand
MAMarzieh Alikhasi
Marzieh Alikhasi
This study aimed to evaluate how repeated use of milling diamond burs with different coarseness affects surface roughness, and marginal and internal adaptation of CAD/CAM veneers. Forty leucite-reinforced glass-ceramic veneers were milled in 2 groups based on the milling mode (with fine or extra-fine bur sets). In each group, every 10 veneers were milled with a new bur set. All veneers were cemented to bovine teeth and then polished. Labial surface roughness was measured before cementation, and after polishing. Marginal and internal discrepancies were measured using a field emission scanning electron microscope. Three-way and two-way mixed repeated measures ANOVA were applied to assess changes in surface roughness values of veneers and discrepancy values, respectively. The Bonferroni correction was applied for multiple comparisons. Repeated use of a milling diamond bur set had a significant effect on surface roughness of the veneers (P < .001). Mean surface roughness of the fine milling mode was significantly higher in comparison to that of extra-fine mode before (P = .002) and after (P = .01) polishing. After polishing a significant decrease in surface roughness occurred in fine (P = .02), but not in extra-fine milling mode (P = .99). Repeated use of milling burs significantly affected marginal and internal adaptation between some repeated uses. Marginal and internal adaptation were significantly affected by repeated use of milling diamond burs up to 10 times between some repeated uses. However, no specific pattern could be established. Repeated use of milling burs could affect surface roughness, surface microcracks, critical defects, and adaptation of CAD/CAM restorations. Therefore, it plays a major role in clinical success of the restorations.

3 October 2023 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
FGFarideh Geramipanah
Farideh Geramipanah
LSLeyla Sadighpour
Leyla Sadighpour
LPLeila Payaminia
Leila Payaminia
Objectives: The aim of this in vitro study was to evaluate the effect of arch size and implant angulation on the accuracy of digital impression in two intraoral scanners of Trios (3shape) and CEREC (Omnicam).Material and Methods: Four acrylic models each including six implants at sites 11, 12, 15, 17, 23, and 27 were used, including large with parallel implants, large with angled implants, small with parallel implants, and small with angled implants. After tightening the scan bodies, distance measurements were done using a coordinate measuring machine. Then, each model was scanned 10 times using each scanner. Trueness and precision measurements were finally computed.Results: The trueness values ranged from 20 to 260 μm in CEREC Omnicam, and from 40 to 1030 μm in Trios. The precision values ranged from 30 to 190 μm in CEREC Omnicam, while from 50 to 770 μm in Trios. The multivariate test analysis indicated that the measured distances via two scanners and different models show different behaviors. Pairwise interactions between these three variables were significant (p < .05). Pairwise interactions between these variables were also significant. (p < .0001).Conclusions: Arch width could affect the accuracy of digital impression; by rotating toward the second quadrant and end points of the scan, errors have increased. However, the angulation of the implants had no effect on the accuracy of digital impression. The CEREC Omnicam scanner showed higher accuracy (trueness and precision) compared to the Trios (3shape) one.