Tony Felefly

Tony Felefly

Auto-generated profile, based on publicly available information

Tony Felefly

Radiation Oncology Department, Hôtel-Dieu de Lévis, Lévis, QC, Canada

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2025 in Cancer/Radiothérapie
Verified
Journal Article
Closed access
TFTony Felefly
Tony Felefly
AJAlborz Jooya
Alborz Jooya
SLSelena Laprade
Selena Laprade
SRSoumyajit Roy
Soumyajit Roy
SMShawn Malone
Shawn Malone
SMScott C. Morgan
Scott C. Morgan

19 February 2026 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
JCJoe Cordahi
Joe Cordahi
NSNikolaos Shinas
Nikolaos Shinas
TFTony Felefly
Tony Felefly
RKRujuta Katkar
Rujuta Katkar
TMTaraneh Maghsoodi-Zahedi
Taraneh Maghsoodi-Zahedi
HGHassem Geha
Hassem Geha
This project aims to establish a triage system for oral and maxillofacial cone-beam computed tomography (CBCT) scans by developing a neural network to identify high-priority cases. Two hundred scans and reports were reviewed to form two cohorts: Group A included 100 patients with significant oral and maxillofacial findings in the oral and maxillofacial region, and Group B included 100 patients without major findings. Scans with only minor abnormalities were assigned to Group B. CBCT images from the groups were merged and split into training (70%) and validation (30%) sets. Two 3D convolutional neural network (3D-CNN) models were developed using Python and Keras: Model 1, inspired by Zunair et al., and Model 2, based on a modified VGG-16 architecture. Data augmentation, the Adam optimizer, and early stopping were applied during training. Each model was trained five times with randomized dataset shuffling, and performance was evaluated using ROC-AUC, accuracy, precision, recall, and F1-score. A Welch’s t -test was used to compare model performance. Both models had excellent performance with Model 2 achieving a slightly higher mean ROC-AUC of 0.918 on validation with no statistically significant inter-model performance ( p = 0.078). Model 2 featured advanced architecture with four convolutional blocks and dense layers, optimizing accuracy (0.960) and precision (0.962) in training. In this study, we successfully developed an accurate 3D-CNN based on CBCT images to distinguish between high-priority scans and routine reports. To the best of our knowledge, this is the first study to address this specific task.