Peter Klason

Peter Klason

Auto-generated profile, based on publicly available information

Peter Klason

SP Technical Research Institute of Sweden

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2006 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TBT. Moe Børseth
T. Moe Børseth
BSB. G. Svensson
B. G. Svensson
AKA. Yu. Kuznetsov
A. Yu. Kuznetsov
PKP. Klason
P. Klason
QZQ. X. Zhao
Q. X. Zhao
MWM. Willander
M. Willander
Photoluminescence spectroscopy has been used to study single crystalline ZnO samples systematically annealed in inert, Zn-rich and O-rich atmospheres. A striking correlation is observed between the choice of annealing ambient and the position of the deep band emission (DBE) often detected in ZnO. In particular, annealing in O2 results in a DBE at 2.35±0.05eV , whereas annealing in the presence of metallic Zn results in DBE at 2.53±0.05eV . The authors attribute the former band to zinc vacancy (VZn) related defects and the latter to oxygen vacancy (VO) related defects. Additional confirmation for the VO and VZn peak identification comes from the observation that the effect is reversible when O- and Zn-rich annealing conditions are switched. After annealing in the presence of ZnO powder, there is no indication for the VZn - or VO -related bands, but the authors observe a low intensity yellow luminescence band peaking at 2.17eV , probably related to Li, a common impurity in hydrothermally grown ZnO.

17 November 2005 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
QZQ. X. Zhao
Q. X. Zhao
PKP. Klason
P. Klason
MWM. Willander
M. Willander
HZH. M. Zhong
H. M. Zhong
WLW. Lu
W. Lu
JYJ. H. Yang
J. H. Yang
A set of bulk ZnO samples implanted with O and Zn at various densities were investigated by photoluminescence. The implantation concentration of O and Zn is varied between 1×1017∕cm3 and 5×1019∕cm3 . The samples were thermally treated in an oxygen gas environment after the implantation. The results clearly show the influence of O and Zn implantations on the deep-level emission. By comparing the photoluminescence spectra for the samples with different implantations, we can conclude that the VZn is responsible to the observed deep-level emission. In addition, a novel transition at the emission energy of 3.08eV at 77K appears in the O-implanted sample with 5×1019∕cm3 implantation concentration. The novel emission is tentatively identified as O-antisite OZn .

1 February 2008 in Solid State Communications
Verified
Journal Article
Closed access
PKPeter Klason
Peter Klason
TBThomas Moe Børseth
Thomas Moe Børseth
QZQing X. Zhao
Qing X. Zhao
BSBengt G. Svensson
Bengt G. Svensson
AKAndrej Yu. Kuznetsov
Andrej Yu. Kuznetsov
MWMagnus Willander
Magnus Willander

29 March 2007 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
QZQ.X. Zhao
Q.X. Zhao
PKP. Klason
P. Klason
MWM. Willander
M. Willander

1 April 2009 in Microelectronics Journal
Verified
Journal Article
Closed access
PKP. Klason
P. Klason
MRM.M. Rahman
M.M. Rahman
QHQ.-H. Hu
Q.-H. Hu
ONOmer Nour
Omer Nour
RTR. Turan
R. Turan
MWM. Willander
M. Willander

1 December 2015 in Meteorological Applications
Verified
Journal Article
Open access
PDF file
AMAndrea Merlone
Andrea Merlone
GLG. Lopardo
G. Lopardo
Francesca SannaFrancesca Sanna
Francesca Sanna
SBS. Bell
S. Bell
RBR. Benyon
R. Benyon
RUR. Underwood
R. Underwood
The study describes significant outcomes of the ‘Metrology for Meteorology’ project, MeteoMet, which is an attempt to bridge the meteorological and metrological communities. The concept of traceability, an idea used in both fields but with a subtle difference in meaning, is at the heart of the project. For meteorology, a traceable measurement is the one that can be traced back to a particular instrument, time and location. From a metrological perspective, traceability further implies that the measurement can be traced back to a primary realization of the quantity being measured in terms of the base units of the International System of Units, the SI. These two perspectives reflect long‐standing differences in culture and practice and this project – and this study – represents only the first step towards better communication between the two communities.The 3 year MeteoMet project was funded by the European Metrology Research Program (EMRP) and involved 18 European National Metrological Institutes, 3 universities and 35 collaborating stakeholders including national meteorology organizations, research institutes, universities, associations and instrument companies.The project brought a metrological perspective to several long‐standing measurement problems in meteorology and climatology, varying from conventional ground‐based measurements to those made in the upper atmosphere. It included development and testing of novel instrumentation as well as improved calibration procedures and facilities, instrument intercomparison under realistic conditions and best practice dissemination. Additionally, the validation of historical temperature data series with respect to measurement uncertainties and a methodology for recalculation of the values were included.