Amar Dhanantwari

Amar Dhanantwari

Auto-generated profile, based on publicly available information

Amar Dhanantwari

Philips Healthcare, Cleveland, OH, 44143, USA

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2017 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
NRNegin Rassouli
Negin Rassouli
MEMaryam Etesami
Maryam Etesami
ADAmar Dhanantwari
Amar Dhanantwari
PRPrabhakar Rajiah
Prabhakar Rajiah
Detector-based spectral computed tomography is a novel dual-energy CT technology that employs two layers of detectors to simultaneously collect low- and high-energy data in all patients using standard CT protocols. In addition to the conventional polyenergetic images created for each patient, projection-space decomposition is used to generate spectral basis images (photoelectric and Compton scatter) for creating multiple spectral images, including material decomposition (iodine-only, virtual non-contrast, effective atomic number) and virtual monoenergetic images, on-demand according to clinical need. These images are useful in multiple clinical applications, including- improving vascular contrast, improving lesion conspicuity, decreasing artefacts, material characterisation and reducing radiation dose. In this article, we discuss the principles of this novel technology and also illustrate the common clinical applications. Teaching points • The top and bottom layers of dual-layer CT absorb low- and high-energy photons, respectively. • Multiple spectral images are generated by projection-space decomposition. • Spectral images can be generated in all patients scanned in this scanner.

1 January 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
KKKevin Kalisz
Kevin Kalisz
NRNegin Rassouli
Negin Rassouli
ADAmar Dhanantwari
Amar Dhanantwari
DJDavid Jordan
David Jordan
PRPrabhakar Rajiah
Prabhakar Rajiah

18 April 2017 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
NRNegin Rassouli
Negin Rassouli
HCHamid Chalian
Hamid Chalian
PRPrabhakar Rajiah
Prabhakar Rajiah
ADAmar Dhanantwari
Amar Dhanantwari
LLLuis Landeras
Luis Landeras

20 September 2007 in Medical Physics
Verified
Journal Article
Closed access
NSN. A. Shkumat
N. A. Shkumat
JSJ. H. Siewerdsen
J. H. Siewerdsen
ADA. C. Dhanantwari
A. C. Dhanantwari
DWD. B. Williams
D. B. Williams
SRS. Richard
S. Richard
RMR. Van Metter
R. Van Metter

17 May 2016 in Scientific Reports
Verified
Journal Article
Open access
ABAlly Leigh Bernstein
Ally Leigh Bernstein
ADAmar Dhanantwari
Amar Dhanantwari
MJMartina Jurcova
Martina Jurcova
RCRabee Cheheltani
Rabee Cheheltani
PNPratap Chandra Naha
Pratap Chandra Naha
DCDavid Peter Cormode
David Peter Cormode
Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity and may allow lower contrast agent doses to be used.

1 January 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
OOOrhan Ozguner
Orhan Ozguner
ADAmar Dhanantwari
Amar Dhanantwari
SHSandra Halliburton
Sandra Halliburton
GWGezheng Wen
Gezheng Wen
SUSteven Utrup
Steven Utrup
DJDavid W Jordan
David W Jordan
This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital’s clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm −1 . NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.