Danyang Li

Danyang Li

Auto-generated profile, based on publicly available information

Danyang Li

Southern Medical Univ. (China)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DLDanyang Li
Danyang Li
ZBZhaoying Bian
Zhaoying Bian
SLSui Li
Sui Li
JHJi He
Ji He
DZDong Zeng
Dong Zeng
JMJianhua Ma
Jianhua Ma
Deep learning (DL)-based methods show great potential in computed tomography (CT) imaging field. The DL-based reconstruction methods are usually evaluated on the training and testing datasets which are obtained from the same distribution, i.e., the same CT scan protocol (i.e., the region setting, kVp, mAs, etc.). In this work, we focus on analyzing the robustness of the DL-based methods against protocol-specific distribution shifts (i.e., the training and testing datasets are from different region settings, different kVp settings, or different mAs settings, respectively). The results show that the DL-based reconstruction methods are sensitive to the protocol-specific perturbations which can be attributed to the noise distribution shift between the training and testing datasets. Based on these findings, we presented a low-dose CT reconstruction method using an unsupervised strategy with the consideration of noise distribution to address the issue of protocol-specific perturbations. Specifically, unpaired sinogram data is enrolled into the network training, which represents unique information for specific imaging protocol, and a Gaussian mixture model (GMM) is introduced to characterize the noise distribution in CT images. It can be termed as GMM based unsupervised CT reconstruction network (GMM-unNet) method. Moreover, an expectation-maximization algorithm is designed to optimize the presented GMM-unNet method. Extensive experiments are performed on three datasets from different scan protocols, which demonstrate that the presented GMM-unNet method outperforms the competing methods both qualitatively and quantitatively.

24 May 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
DZDong Zeng
Dong Zeng
LWLei Wang
Lei Wang
MGMingrui Geng
Mingrui Geng
SLSui Li
Sui Li
YDYun Deng
Yun Deng
JMJianhua Ma
Jianhua Ma
Deep learning (DL) techniques have expedited successful applications in computed tomography (CT) imaging field and have obtained remarkable outcomes. Most of the techniques require the precollection of large numbers of low-dose/high-dose CT image pairs and the training of the network in a supervised end-to-end manner. However, there are some evident limitations to such a supervised learning manner: 1) it is time intensive to acquire sufficient training sample pairs, as expected, and the low-dose CT images are usually simulated from the high-dose images due to the radiation exposure to the patients. In addition, it is difficult to obtain well-registered data pairs, especially for the torso region and 2) most current methods fail to utilize the abundant information in the unlabeled low-dose CT images, which are easier to obtain. In this work, we develop a new method for low-dose CT sinogram recovery with a noise-generating-mechanism-driven unsupervised DL network (Un-SinoNet), wherein the unlabeled low-dose CT sinograms are enrolled into the network training. The proposed Un-SinoNet considers the statistical variations in the noise-generation mechanism of CT measurement and its prior characteristics under a maximum a posteriori probability (MAP) framework, and then learns the proper gradient of the low-dose CT sinograms in a purely unsupervised manner. Specifically, similar to the labeled high-dose CT sinogram, the gradient information in the unlabeled CT sinogram can be used for efficient network training. Moreover, with a few low-dose/high-dose sinogram pairs, the proposed Un-SinoNet can be extended to the semi-supervised DL network (Semi-SinoNet) by combining the conventional objective function and the MAP objective function. The proposed Un-SinoNet and Semi-SinoNet are validated via the LUNGMAN phantom, and simulated Mayo Clinic patient datasets. With the two methods, this study achieves better image resolution and noise removal effects than the competing methods, and the presented Semi-SinoNet produces similar or even better performance compared with the supervised DL network.

11 June 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DLDanyang Li
Danyang Li
DZDong Zeng
Dong Zeng
SLSui Li
Sui Li
Yongshuai GeYongshuai Ge
Yongshuai Ge
ZBZhaoying Bian
Zhaoying Bian
JMJianhua Ma
Jianhua Ma
Photon counting computed tomography (PCCT) has the ability to identify individual photons, resulting in quantitative material identification. Meanwhile, several technical challenges still exist in current PCCT imaging systems, including increased noise and suboptimal bin selection. These nonideal effects can substantially degrade the reconstruction performance and material estimation accuracy. To address these issues, in this work, we present a novel system for high-performance spectral PCCT imaging, which is a combination of multiple dynamic modulations, interpolation-based measurements processing strategy and advanced reconstruction method. For simplicity, this new PCCT imaging system is referred to as “MDM-PCCT”. Specifically, the multiple dynamic modulations consist of dynamic kVp modulation, dynamic spectrum modulation and dynamic energy threshold modulation. In the dynamic kVp modulation, three kVp values, i.e., 80, 110 and 140, are included, and the tube voltage waveform follows a sinusoidal curve which is more practical than the rectangular curve in the fast kV switching mode. In the dynamic spectrum modulation, the X-ray spectra are processed by selective spatial-spectral filters to balance the X-ray fluxes and increase the spectral separation. In the dynamic energy threshold modulation, the energy threshold is adaptively changed to determine the optimal bin selection. Furthermore, we propose an energy threshold determination method and interpolation-based measurements processing strategy to address the issue of non-uniform and sparse-view PCCT measurements, respectively. In addition, by considering the intrinsic characteristics of the MDM-PCCT images, we utilize an enhanced total variation regularized model for images reconstruction. Finally, numerical and preclinical studies demonstrate that the presented MDM-PCCT imaging system is capable of yielding uniform and high-fidelity PCCT measurements with noise consistency, and the presented reconstruction method further improves the image quality and material decomposition accuracy.

16 March 2020
Verified
Conference Paper
Closed access
PDF file
DLDanyang Li
Danyang Li
SLSui Li
Sui Li
MZManman Zhu
Manman Zhu
QGQi Gao
Qi Gao
ZBZhaoying Bian
Zhaoying Bian
JMJianhua Ma
Jianhua Ma
Deep learning (DL) networks show a great potential in computed tomography (CT) imaging field. Most of them are supervised DL network greatly based on their capability and the amount of CT training data (i.e., low-dose CT measurements/high-quality ones). However, collection of large-scale CT datasets are time-consuming and expensive. In addition, the training and testing CT datasets used for supervised DL network are highly desired similarities in CT scan protocol (i.e., similar anatomical structure, and same kVp setting). These two issues are particularly critical in spectral CT imaging. In this work, to address the issues, we presents an unsupervised data fidelity enhancement network (USENet) to produce high-quality spectral CT images. Specifically, the presented USENet consists of two parts, i.e., supervised network and unsupervised network. In the supervised network, the spectral CT image pairs at 140 kVp (low-dose CT images/high-dose ones) are used for network training. It should be noted that there is a great difference of CT value between spectral CT images at 140 kVp and 80 kVp, and the supervised network trained with CT images at 140 kVp cannot be directly used for CT image reconstruction at 80 kVp. Then unsupervised network enrolls physical model and the spectral CT measurements at 80 kVp for fine-tuning the supervised network, which is the major contribution of the presented USENet method. Finally, accurate spectral CT reconstructions are achieved for the sparse-view and low-dose cases, which fully demonstrate the effectiveness of the presented USENet method.

16 March 2020
Verified
Conference Paper
Closed access
PDF file
LWLei Wang
Lei Wang
QGQi Gao
Qi Gao
MMMingQiang Meng
MingQiang Meng
SLSui Li
Sui Li
MZManman Zhu
Manman Zhu
JMJianhua Ma
Jianhua Ma
Fully supervised deep learning (DL) methods have been widely used in low-dose CT (LDCT) imaging field and can usually achieve high accuracy results. These methods require a large labeled training set which consists of pairs of LDCT images as well as their corresponding high-dose CT (HDCT) ones. They successfully learn intermediate concept of features describing important components in CT images, such as noise distribution, and structure details, which is important to capture dependencies from LDCT image to HDCT ones. However, it should be noted that it is quite time-consuming and costly to obtain such a large of labeled CT images especially the HDCT images are limited in clinics. In comparison, lots of unlabeled LDCT images are usually easily accessible and massive critical information latent in the unlabeled LDCT can be leveraged to further boost restoration performance. Therefore, in this work, we present a semi-supervised noise distribution learning network to suppress noise-induced artifacts in the LDCT images. For simplicity, the presented network in termed as "SNDL-Net". The presented SNDL-Net consists of two sub-networks, i.e., supervised network, and unsupervised network. In the supervised network, the LDCT/HDCT image pairs are used for network training. And the unsupervised network considers the complex noise distribution in the LDCT images, and model the noise with a Gaussian mixture framework, then learns the proper gradient of LDCT images in a purely unsupervised manner. Similar with the supervised network training, the gradient information in a large of unlabeled LDCT images can be used for unsupervised network training. Moreover, to learn the noise distribution accurately, the discrepancy between the learned noise distribution in the supervised network and learned noise distribution in the unsupervised network can be modeled by a Kullback-Leibler (KL) divergence. Experiments on the Mayo clinic dataset verify the method is effective in low-dose CT image restoration with only a small amount of labeled data compared to previous supervised deep learning methods.

10 July 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
PWPengfei Wang
Pengfei Wang
DLDanyang Li
Danyang Li
YZYaoduo Zhang
Yaoduo Zhang
GCGaofeng Chen
Gaofeng Chen
YWYongbo Wang
Yongbo Wang
JHJi He
Ji He
Although supervised deep learning methods have made significant advances in low-dose computed tomography (LDCT) image denoising, these approaches typically require pairs of low-dose and normal-dose CT images for training, which are often unavailable in clinical settings. Self-supervised deep learning (SSDL) has great potential to cast off the dependence on paired training datasets. However, existing SSDL methods are limited by the neighboring noise independence assumptions, making them ineffective for handling spatially correlated noises in LDCT images. To address this issue, this paper introduces a novel SSDL approach, named, Noise-Aware Blind Spot Network (NA-BSN), for high-quality LDCT imaging, while mitigating the dependence on the assumption of neighboring noise independence. NA-BSN achieves high-quality image reconstruction without referencing clean data through its explicit noise-aware constraint mechanism during the self-supervised learning process. Specifically, it is experimentally observed and theoretical proven that the l1 norm value of CT images in a downsampled space follows a certain descend trend with increasing of the radiation dose, which is then used to construct the explicit noise-aware constraint in the architecture of BSN for self-supervised LDCT image denoising. Various clinical datasets are adopted to validate the performance of the presented NA-BSN method. Experimental results reveal that NA-BSN significantly reduces the spatially correlated CT noises and retains crucial image details in various complex scenarios, such as different types of scanning machines, scanning positions, dose-level settings, and reconstruction kernels.