The majority of embolisms associated with atrial fibrillation (AF) are from the left atrial appendage (LAA). To treat the existing thrombus, warfarin and novel anticoagulants have been used. However, there has been no clinical information regarding the difference of the effects of congealing the fibrinogenolysis system among these oral anticoagulants. Here, we report a case of persistent AF, in whom apixaban, factor Xa inhibitor resolved an LAA clot refractory to warfarin and direct thrombin inhibition. Factor Xa inhibitor, apixaban, could resolve the left appendage thrombosis refractory to warfarin and dabigatran.
1 November 2018 in International Journal of Cardiology
Background: Noninvasive electrocardiographic markers (NIEMs) are promising arrhythmic risk stratification tools for assessing the risk of sudden cardiac death. However, little is known about their utility in patients with chronic kidney disease (CKD) and organic heart disease. This study aimed to determine whether NIEMs can predict cardiac events in patients with CKD and structural heart disease (CKD‐SHD).Methods: We prospectively analyzed 183 CKD‐SHD patients (median age, 69 years [interquartile range, 61−77 years]) who underwent 24‐h ambulatory electrocardiographic monitoring and assessed the worst values for ambulatory‐based late potentials (w‐LPs), heart rate turbulence, and nonsustained ventricular tachycardia (NSVT). The primary endpoint was the occurrence of documented lethal ventricular tachyarrhythmias (ventricular fibrillation or sustained ventricular tachycardia) or cardiac death. The secondary endpoint was admission for cardiovascular causes.Results: Thirteen patients reached the primary endpoint during a follow‐up period of 24 ± 11 months. Cox univariate regression analysis showed that existence of w‐LPs (hazard ratio [HR] = 6.04, 95% confidence interval [CI]: 1.4−22.3, p = .007) and NSVT [HR = 8.72, 95% CI: 2.8−26.5: p < .001] was significantly associated with the primary endpoint. Kaplan–Meier analysis demonstrated that the combination of w‐LPs and NSVT resulted in a lower event‐free survival rate than did other NIEMs (p < .0001). No NIEM was useful in predicting the secondary endpoint, although the left ventricular mass index was correlated with the secondary endpoint.Conclusion: The combination of w‐LPs and NSVT was a significant risk factor for lethal ventricular tachyarrhythmias and cardiac death in CKD‐SHD patients.
Objective Recently, concern has increased regarding the hazards of radiation exposure in patients and laboratory staff. Since the numbers of complex catheter ablations (CA) performed, duration of procedure times, and need for multiple sessions have increased, radiation exposure during each session needs to be minimised. Our study aimed to assess the impact of awareness on radiation exposure during CA for atrial fibrillation (AF). Methods Mini-course lectures was delivered to the physicians and staff in the electrophysiology division. Its effect on the fluoroscopic time and radiation dose during AF ablation before (Group I, n=70), shortly after (Group II: n=70) and remotely after the mini-lecture (Group III, n=70) were evaluated. Patient demographics, preoperative testing and procedural parameters were collected. Results The fluoroscopic time significantly reduced after the lecture (Group I and II: 25.1±10.0 and 15.1±7.3 min, respectively (p<0.0001)), and remained so in Group III (13.0±5.4 min), despite the increase in the number of persistent AFs. The radiation dose also significantly reduced (Groups I, II, III: 295.0±263.0, 109.6±103.5 and 110.1±89.6 mGy, respectively (p<0.0001)). Conclusion Awareness on radiation exposure led to a significant reduction in fluoroscopic time and radiation dose during CA for AF, the effect of which persisted even to remote periods following the procedure.
9 January 2020 in Journal of Cardiovascular Electrophysiology
Structured Background: When performing catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT), it can be difficult to maintain a safe distance from the His recording site to avoid AV block in patients with a short distance between this recording site to the coronary sinus (CS) ostium (small triangle of Koch [TOK]). In this study, we sought to identify parameters predicting small TOK and test these parameters in patients undergoing AVNRT catheter ablation.Methods: Twenty‐eight patients who underwent catheter ablation of atrial fibrillation using a three‐dimensional (3D) electroanatomical mapping system (EAM) with computed tomography (CT) merge (23 males; mean age, 65.8±12.1 years) were included. The shortest distance between the CS ostium and His recording sites (His‐CSd) was measured on the EAM. Aortic (Ao) unfolding in chest X‐ray scan, Ao angle to the LV, Ao length, Ao to the right ventricular distance, size of the Valsalva in the CT scan, and parameters of echocardiogram were evaluated. The identified parameters were subsequently tested as predictors for small TOK in patients undergoing AVNRT ablation.Results: The size of TOK was associated with Ao length (r = −0.70, p<0.01), left ventricular end‐systolic dimension (LVDs) (r = −0.51, p<0.01), and Ao unfolding. In patients with AVNRT, only Ao unfolding predicted a smaller TOK.Conclusions: Small TOK was associated with longer Ao, larger LVDs, and Ao unfolding. Of these, Ao unfolding was associated with smaller TOK in patients with AVNRT.