1 January 2010 in Journal of Applied Geodesy
It is necessary to use different sensors in an integrated manner – GPS, accelerometer, inclination sensor and so on – in order to monitor and identify static, quasi-static and resonant response of tall buildings subjected to wind loading. There are some differences among these sensors with respect to data sampling rate, data quality, and their measurement accuracy. Therefore, using different sensors together for a monitoring project is important because of the complementary nature of each sensor. In this study, the behaviour of a tall reinforced concrete building (30 stories high) under wind load has been monitored using GPS and inclination sensors. This paper assesses the dynamic measurement quality and reliability of inclinometers for building monitoring applications, and discusses the strengths and weaknesses of GPS vis-a-vis the use of inclination sensors for monitoring the dynamic response of tall buildings under wind load. Data collected by these sensors have been analysed in the time and frequency domains. It was found that GPS observations were distorted by multipath caused by a reflecting surface on top of the building. From the analyses in the frequency domain, the 1 st mode natural frequencies of the building determined from both sensors agree very well with each other. The discrepancy of this measured 1 st mode natural frequency compared to that derived from FEM (Finite Element Model) prediction is 7%.
1 October 2011 in Survey Review
3 April 2013 in Geomatics, Natural Hazards and Risk
Turkey is a country that has active fault lines and is prone to earthquake. The positional variations resulted from the Van earthquake (a magnitude of M = 7.2) on 23 October 2011 and were calculated by using data from CORS-TR (Continuously Operating Reference Station network) stations. The GPS data from the CORS-TR stations effected from the earthquake were evaluated by the BERNESE 5.0 software. For calculating the positional displacements in the CORS-TR stations after the earthquake that occurred in Van, the measurements from 16 International GNSS Service (IGS) stations around Turkey, where their coordinates and velocity vectors were considered to be constant at the ITRF2005 datum. The greatest variation was measured from the Muradiye station, which is the closest point to the epicentre of the earthquake. The variation in this station was −42.7 mm in the vertical direction, −60.3 mm in the northern direction and −18.7 mm in the eastern direction.
4 April 2017 in International Journal of Civil Engineering
1 March 2012 in Acta Geodaetica et Geophysica Hungarica
Nowadays, GPS is the best positioning system with its constellation, but number of GLONASS satellites increased to the required number, with launched new ones, for positioning. With recent revitalization of GLONASS, a great number of high precision GLONASS and GPS/GLONASS receivers have been produced. In this paper, baselines of two networks have been analyzed in order to assess the usability of GLONASS on global positioning. In both networks, repeatabilities of results were investigated by using GPS, GLONASS and GPS/GLONASS data. Results revealed that repeatabilities of all baselines by using GLONASS observations are not consistent when compared to the GPS and GPS/GLONASS.
1 June 2018 in International Journal of Engineering and Geosciences
The ionosphere is a layer of atmosphere 60 km to 1100 km above the earth and is composed of solar rays and ionized gases. The ionosphere is an important layer affecting Global Navigation Satellite System (GNSS) measures. The quality of GNSS measures is directly related to the changes in the ionosphere. For this reason, monitoring changes in the ionosphere is quite important. One of the important parameters expressing the characteristic of the ionosphere is the Total Electron Content (TEC), which is a function of electron density exhibiting transformation with solar radiation. In this study, 68 stations including 56 Continuously Operating Reference Stations-Turkey (CORS-TR) stations and also IGS stations were taken for evaluation. Bernese v5.2 GNSS software developed by Bern University of Switzerland was employed at the evaluation stage. From 2009 until 2015, TEC values were calculated at two hourly intervals, one day for each month. In the study, where a Single Layer Model was used, TEC values obtained from GNSS measurements have been compared with the TEC (IRI-2012 TEC) values obtained from the global ionosphere map (GIM-TEC) and the international ionosphere reference model programme published by the Centre for Orbit Determination in Europe (CODE), the European Space Agency (ESA), and the Jet Propulsion Laboratory (JPL). As a result, the regional (RIM) TEC values and the global (CODE, ESA, JPL) TEC values showed a large similarity, and the IRI obtained TEC values remained lower than these four values was observed. Correlation coefficient was calculated to determine the relationship between regional TEC values obtained after the evaluation and global TEC values. There is a positive and quite high correlation between the regional (RIM) TEC values produced by the calculated correlation coefficients and the global (CODE, ESA, JPL) TEC and IRI TEC values.