In this research, a combined photocatalytic and biological treatment is proposed for the elimination of pollutants present in textile wastewater using a natural erionite zeolite (PE) and aluminum oxide (PA) synthesized by the sol-gel method as photocatalysts, and solar radiation. Both catalysts were characterized by XRD, SEM, and EDS. For biological treatment two bacterial consortium were used: BC1 (Escherichia coli N16, Serratia k120, Pseudomonas putida B03 and Enterobacter hormaechei), and consortium BC2 (Escherichia coli N16, Serratia Mc107, Enterobacter N9, Enterobacter hormaechei Mc9). The photocatalytic and microbiological treatments were carried out initially separately and subsequently in a sequential manner, first the photocatalytic followed by the microbiological to determine if a synergistic effect was achieved. Comparing the photocatalytic performance, erionite showed higher performance of dyes degradation (54.75%) than alumina (28.62%). While in the biological process, BC1 decreased the dye concentration to 56.93% and BC2 to 53.56%. Finally, the best combined process was PA+BC1 reaching pollutants degradation 64.62%, showing that the application of both processes promotes a decolorization in textile wastewater. The water resulting from the combined photocatalysis-microbiological degradation processes was tested for toxicity using Daphnia magna, obtaining that none of the effluents shows toxicity.
This paper presents an analysis of a gate-driving technique for enhancing the switching performance of gallium nitride (GaN) power transistors. The technique consists of modifying the Pulse Width Modulated (PWM) signal that is applied to the gate of transistors by using diodes and a totem pole circuit. As purpose of this technique is to control the turn-on and turnoff HEMT GaN transitions and reduce the oscillations caused by high-speed operation without increasing power losses. LTsipice is used for analyzing the gate driving technique by simulations considering models of commercial components. Simulation results show the viability of the proposed, which can reduce the ringing in the GaN transitions without affecting their performance.
El presente trabajo tiene como objetivo, acoplar una estrategia de control de detección y reconfiguración de fallas basada en planitud, en conjunto con un controlador Predictivo de Modelo lineal para el control de trayectorias automático de un cuadrirrotor, en donde los controladores tengan la posibilidad de adaptarse y reconfigurarse ante la aparición de un posible evento de falla y garantizar la supervivencia del cuadrirrotor.
En este artículo, un modelo matemático multivariable no lineal de una central hidroeléctrica reversible, desarrollado en Matlab-Simulink, es empleado para evaluar el desempeño de un controlador Proporcional Integral Derivativo (pseudo derivativo) con anti-windup, donde las acciones integral y derivativa son de orden fraccional. Este control se muestra robusto, manteniendo su rendimiento tanto en el caso de respuesta directa como en la respuesta de acoplamiento cruzado. De igual forma, se muestra la ventaja de usar un filtro para reducir la interacción de acoplamiento cruzado de este sistema. El efecto de este filtro, de orden fraccional, en el desempeño del sistema, se muestra mediante la reducción de la integral del error cuadrático.
Structural health monitoring of jacket-type substructures of offshore wind turbines is key to ensuring their availability under limited access and combined wind–wave loading. This work presents a functional horizontal-axis wind turbine prototype on a modular, demountable A36-steel jacket substructure inspired by the OWEC Quattropod model, conceived to induce structural damage in a controlled and repeatable manner. A synchronized wireless acquisition system with seven triaxial ADXL355 accelerometers was implemented over TCP/IP, together with a methodology to classify structural faults from vibration signals. The resulting database comprises the healthy state and three damage conditions at four rotational speeds, over 48 balanced experimental runs. After sliding-window segmentation, z -score normalization and dimensionality reduction by principal component analysis, six classifiers were compared at five window lengths using leave-one-repetition-out cross-validation, which prevents data leakage between partitions. The best configurations were the support vector machine (SVM) with a quadratic kernel ( , 0.20 s; accuracy and macro- F 1 score of ) and linear discriminant analysis (LDA) ( , 0.78 s; accuracy and macro- F 1 score of ), both with an area under the ROC curve and average precision of at least 0.997. These figures should be interpreted considering that the Fault 1 condition was acquired under a differentiated excitation regime; by restricting the evaluation of the original classifier predictions to the three conditions recorded under an identical protocol, the accuracy is 0.995 for the quadratic SVM and 0.982 for LDA. LDA combines stability, low computational cost and interpretability: training in less than a second and processing over 24 000 observations per second, indicating its computational viability for online structural monitoring. The results constitute a first laboratory validation of the proposed methodology. Its application to a real installation requires addressing the environmental and scale conditions of a marine site.