To evaluate accuracy for 2 deformable image registration methods (in-house B-spline and MIM freeform) using image pairs exhibiting changes in patient orientation and lung volume and to assess the appropriateness of registration accuracy tolerances proposed by the American Association of Physicists in Medicine Task Group 132 under such challenging conditions via assessment by expert observers. Four-dimensional computed tomography scans for 12 patients with lung cancer were acquired with patients in prone and supine positions. Tumor and organs at risk were delineated by a physician on all data sets: supine inhale (SI), supine exhale, prone inhale, and prone exhale. The SI image was registered to the other images using both registration methods. All SI contours were propagated using the resulting transformations and compared with physician delineations using Dice similarity coefficient, mean distance to agreement, and Hausdorff distance. Additionally, propagated contours were anonymized along with ground-truth contours and rated for quality by physician-observers. Averaged across all patients, the accuracy metrics investigated remained within tolerances recommended by Task Group 132 (Dice similarity coefficient >0.8, mean distance to agreement <3 mm). MIM performed better with both complex (vertebrae) and low-contrast (esophagus) structures, whereas the in-house method performed better with lungs (whole and individual lobes). Accuracy metrics worsened but remained within tolerances when propagating from supine to prone; however, the Jacobian determinant contained regions with negative values, indicating localized nonphysiologic deformations. For MIM and in-house registrations, 50% and 43.8%, respectively, of propagated contours were rated acceptable as is and 8.2% and 11.0% as clinically unacceptable. The deformable image registration methods performed reliably and met recommended tolerances despite anatomically challenging cases exceeding typical interfraction variability. However, additional quality assurance measures are necessary for complex applications (eg, dose propagation). Human review rather than unsupervised implementation should always be part of the clinical registration workflow.
Purpose: Locally advanced non‐small cell lung cancer (NSCLC) patients may experience dramatic changes in anatomy during radiotherapy and could benefit from adaptive radiotherapy (ART). Deformable image registration (DIR) is necessary to accurately accumulate dose during plan adaptation, but current algorithms perform poorly in the presence of large geometric changes, namely atelectasis resolution. The goal of this work was to develop a DIR framework, named Consistent Anatomy in Lung Parametric imagE Registration (CALIPER), to handle large geometric changes in the thorax.Methods: Registrations were performed on pairs of baseline and mid‐treatment CT datasets of NSCLC patients presenting with atelectasis at the start of treatment. Pairs were classified based on atelectasis volume change as either full, partial, or no resolution. The evaluated registration algorithms consisted of several combinations of a hybrid intensity‐ and feature‐based similarity cost function to investigate the ability to simultaneously match healthy lung parenchyma and adjacent atelectasis. These components of the cost function included a mass‐preserving intensity cost in the lung parenchyma, use of filters to enhance vascular structures in the lung parenchyma, manually delineated lung lobes as labels, and several intensity cost functions to model atelectasis change. Registration error was quantified with landmark‐based target registration error and post‐registration alignment of atelectatic lobes.Results: The registrations using both lobe labels and vasculature enhancement in addition to intensity of the CT images were found to have the highest accuracy. Of these registrations, the mean (SD) of mean landmark error across patients was 2.50 (1.16) mm, 2.80 (0.70) mm, and 2.04 (0.13) mm for no change, partial resolution, and full atelectasis resolution, respectively. The mean (SD) atelectatic lobe Dice similarity coefficient was 0.91 (0.08), 0.90 (0.08), and 0.89 (0.04), respectively, for the same groups. Registration accuracy was comparable to healthy lung registrations of current state‐of‐the‐art algorithms reported in literature.Conclusions: The CALIPER algorithm developed in this work achieves accurate image registration for challenging cases involving large geometric and topological changes in NSCLC patients, a requirement for enabling ART in this patient group.
1 July 2017 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Atelectasis (AT), or collapsed lung, is frequently associated with central lung tumors. We investigated the variation of atelectasis volumes during radiation therapy and analyzed the effect of AT volume changes on the reproducibility of the primary tumor (PT) position. Twelve patients with lung cancer who had AT and 10 patients without AT underwent repeated 4-dimensional fan beam computed tomography (CT) scans during radiation therapy per protocols that were approved by the institutional review board. Interfraction volume changes of AT and PT were correlated with PT displacements relative to bony anatomy using both a bounding box (BB) method and change in center of mass (COM). Linear regression modeling was used to determine whether PT and AT volume changes were independently associated with PT displacement. PT displacement was compared between patients with and without AT. The mean initial AT volume on the planning CT was 189 cm3 (37-513 cm3), and the mean PT volume was 93 cm3 (12-176 cm3). During radiation therapy, AT and PT volumes decreased on average 136.7 cm3 (20-369 cm3) for AT and 40 cm3 (-7 to 131 cm3) for PT. Eighty-three percent of patients with AT had at least one unidirectional PT shift that was greater than 0.5 cm outside of the initial BB during treatment. In patients with AT, the maximum PT COM shift was ≥0.5 cm in all patients and >1 cm in 58% of patients (0.5-2.4 cm). Changes in PT and AT volumes were independently associated with PT displacement (P < .01), and the correlation was smaller with COM (R2 = 0.58) compared with the BB method (R2 = 0.80). The median root mean squared PT displacement with the BB method was significantly less for patients without AT (0.45 cm) compared with those with AT (0.8cm, P = .002). Changes in AT and PT volumes during radiation treatment were significantly associated with PT displacements that often exceeded standard setup margins. Repeated 3-dimensional imaging is recommended in patients with AT to evaluate for PT displacements during treatment.