Hueyjong Shih

Hueyjong Shih

Auto-generated profile, based on publicly available information

Hueyjong Shih

Fourth-year Medical Student. Columbia University Vagelos College of Physicians and Surgeons, New York, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
HSHueyjong Shih
Hueyjong Shih
CBCaley Butler
Caley Butler
AMAndrew Melehy
Andrew Melehy
YNYuming Ning
Yuming Ning
PKPaul Kurlansky
Paul Kurlansky
KTKoji Takeda
Koji Takeda
: OBJECTIVES: This study analyses the position of the HeartMate 3 left ventricular assist device on serial radiographs to assess positional change and possible correlation with adverse events. METHODS: We retrospectively analysed 59 left ventricular assist device recipients who had serial chest radiographs at 1 month, 6 months and 12 months post-implantation between November 2014 and June 2018. We measured pump angle, pump-spine distance and pump-diaphragm depth and investigated their relationship to a composite outcome of heart failure readmission, low flow alarms, stroke or inflow/outflow occlusion requiring surgical repositioning through recurrent event survival modelling. RESULTS: Between 1 and 6 months, the absolute pump-spine distance changed by 10.00 mm (P < 0.01) and the absolute pump-diaphragm depth changed by 18.80 mm (P < 0.01). These parameters did not change significantly between 6 and 12 months post-implantation. Pump angle did not change significantly over any period. Twenty-six patients experienced the composite outcome; in these patients, the median 1-month pump angle was 66.2° (interquartile range 54.5–78.0) as compared to 59.0° (interquartile range 47.0–65.0) in the 33 patients who did not have adverse events (P = 0.04). Pump depth and pump-spine distance at 1 month were not associated with the composite outcome. Change in pump depth between 1 and 6 months [hazard ratio (HR) 1.019; 95% confidence interval (CI) 1.000–1.039] and between 6 and 12 months (HR 1.020; 95% CI 1.000–1.040) were weakly associated with the composite outcome. CONCLUSIONS: Larger pump angles are associated with the composite outcome of position-related adverse events. Pump depth movement is weakly associated with the composite outcome.

24 August 2023 in International Journal of Medical Students
Verified
Journal Article
Open access
PDF file
JKJesper Ke
Jesper Ke
EZEllen Zhang
Ellen Zhang
KKKate Lee Karlin
Kate Lee Karlin
HSHueyjong Shih
Hueyjong Shih
CHChin Hur
Chin Hur
This piece provides a personal perspective of the bias that affects Asian-American medical students in the United States in the clinical wards. In the evolving landscape of medical education, discussions about race, professionalism, and structural change have come to the forefront, especially with regards to patient interactions. However, less has been discussed about bias that may be perpetuated within a clinical team: between medical students, residents, and faculty physicians. This piece builds on these personal experiences to highlight some steps that can range from the individual to institutional level to address some of these biases, especially as it pertains to Asian-American Medical Students. Overall, this piece shares perspectives that draw strongly on personal experiences in the hopes of creating change for both colleagues and aspiring physicians across the medical spectrum.

1 July 2022 in CSurgeries
Verified
Journal Article
Closed access
HSHueyjong Shih
Hueyjong Shih
SFSuzanne Freitag
Suzanne Freitag
Watch a video of a live Lacrimal Probing and Irrigation procedure in addition to hundreds more peer-reviewed surgical video journals - only at CSurgeries.com