Kamal Singhrao

Kamal Singhrao

Auto-generated profile, based on publicly available information

Kamal Singhrao

Department of Radiation Oncology, Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School , Boston, MA 02115

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
JFJie Fu
Jie Fu
KSKamal Singhrao
Kamal Singhrao
MCMinsong Cao
Minsong Cao
VYVictoria Y Yu
Victoria Y Yu
ASAnand P Santhanam
Anand P Santhanam
JLJohn H Lewis
John H Lewis
Electron density maps must be accurately estimated to achieve valid dose calculation in MR-only radiotherapy. The goal of this study is to assess whether two deep learning models, the conditional generative adversarial network (cGAN) and the cycle-consistent generative adversarial network (cycleGAN), can generate accurate abdominal synthetic CT (sCT) images from 0.35T MR images for MR-only liver radiotherapy. A retrospective study was performed using CT images and 0.35T MR images of 12 patients with liver (n = 8) and non-liver abdominal (n = 4) cancer. CT images were deformably registered to the corresponding MR images to generate deformed CT (dCT) images for treatment planning. Both cGAN and cycleGAN were trained using MR and dCT transverse slices. Four-fold cross-validation testing was conducted to generate sCT images for all patients. The HU prediction accuracy was evaluated by voxel-wise similarity metric between each dCT and sCT image for all 12 patients. dCT-based and sCT-based dose distributions were compared using gamma and dose-volume histogram (DVH) metric analysis for 8 liver patients. sCT cycleGAN achieved the average mean absolute error (MAE) of 94.1 HU, while sCT cGAN achieved 89.8 HU. In both models, the average gamma passing rates within all volumes of interest were higher than 95% using a 2%, 2 mm criterion, and 99% using a 3%, 3 mm criterion. The average differences in the mean dose and DVH metrics were within ±0.6% for the planning target volume and within ±0.15% for evaluated organs in both models. Results : demonstrated that abdominal sCT images generated by both cGAN and cycleGAN achieved accurate dose calculation for 8 liver radiotherapy plans. sCT cGAN images had smaller average MAE and achieved better dose calculation accuracy than sCTcyleGAN images. More abdominal patients will be enrolled in the future to further evaluate the two models.

3 July 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
KSKamal Singhrao
Kamal Singhrao
JFJie Fu
Jie Fu
YGYu Gao
Yu Gao
HWHolden Wu
Holden Wu
YYYingli Yang
Yingli Yang
JLJohn H Lewis
John H Lewis
The advent of technologies such as magnetic resonance imaging (MRI)-guided radiation therapy has led to the need for phantom materials that are capable of producing tissue-like contrast on both MRI and computed tomography (CT) imaging modalities. The purpose of this work is to develop a system of easily made and formed materials with adjustable T 1 and T 2 relaxation times, and x-ray attenuation properties, for mimicking soft tissue and bone with both MRI and CT imaging modalities. The effects on T 1 /T 2 relaxation times and CT numbers were quantified for a range of gadolinium contrast (0–25 μ mol g -1 ), agarose (0%–8% w/w), glass microspheres (0%–10% w/w) and CaCO 3 (0%–50% w/w) concentrations in a carrageenan-based gel. 105 gel samples were prepared with the additives, carrageenan and water. Samples were imaged in a 3D-printed holding structure to find the attainable range of T 1 /T 2 relaxation time and CT number combinations. T 1 and T 2 relaxation time maps were generated using voxel-wise inversion-recovery and spin-echo techniques, respectively. A multivariate linear regression model was generated to allow the materials system to be generalized to semi-arbitrary T 1 /T 2 relaxation times and CT numbers. Nine diverse tissue types were mimicked for fit model validation. The achievable T 1 /T 2 relaxation times and CT numbers for the additive concentrations tested in this study spanned from 82 to 2180 ms, 12 to 475 ms, and −117 to +914 Hounsfield units (HU), respectively. The mean absolute error between the fit model predicted and measured T 1 /T 2 relaxation times and CT numbers for the nine tested tissue types was 113 ± 64 ms, 16 ± 26 ms and 11 ± 14 HU, respectively. In conclusion, we have created a system of materials capable of producing tissue-like contrast for 3.0 T MRI and CT imaging modalities.

4 June 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
JSJess Scholey
Jess Scholey
TNTomi Nano
Tomi Nano
KSKamal Singhrao
Kamal Singhrao
OMOsama Mohammad
Osama Mohammad
LSLisa Singer
Lisa Singer
MDMartina Descovich
Martina Descovich
Purpose: CT Hounsfield Units (HUs) are converted to electron density using a calibration curve obtained from physical measurements of an electron density phantom. HU values assigned to an MRI‐derived synthetic computed tomography (sCT) may present a different relationship with electron density compared to CT HU. Correct assignment of sCT HU values is critical for accurate dose calculation and delivery. The goals of this work were to develop a sCT calibration curve using patient data acquired on a clinically commissioned CT scanner and assess for CyberKnife‐ and volumetric modulated arc therapy (VMAT)‐based MR‐only treatment planning of prostate SBRT.Methods: Same‐day CT and MRI simulation in the treatment position were performed on 10 patients treated with SBRT to the prostate. Dixon in‐phase and out‐of‐phase MRIs were acquired on a 3T scanner using a 3D T1‐weighted gradient‐echo sequence to generate sCTs using a commercial sCT algorithm. CT and sCT datasets were co‐registered and HU values compared using mean absolute error (MAE). An optimized HU‐to‐density calibration curve was created based on average HU values across an institutional patient database for each of the four sCT tissue types. Clinical CyberKnife and VMAT treatment plans were generated on each patient CT and recomputed onto corresponding sCTs. Dose distributions computed using CT and sCT were compared using gamma criteria and dose‐volume‐histograms.Results: For the optimized calibration curve, HU values were −96, 37, 204, and 1170 and relative electron densities were 0.95, 1.04, 1.1, and 1.7 for adipose, soft tissue, inner bone, and outer bone, respectively. The proposed sCT protocol produced total MAE of 94 ± 20HU. Gamma values mean ± std (min‐max) were 98.9% ± 0.9% (97.1%–100%) and 97.7% ± 1.3% (95.3%–99.3%) for VMAT and CyberKnife plans, respectively.Conclusion: MRI‐derived sCT using the proposed approach shows excellent dosimetric agreement with conventional CT simulation, demonstrating the feasibility of MRI‐derived sCT for prostate SBRT treatment planning.

1 February 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
KSKamal Singhrao
Kamal Singhrao
DRDan Ruan
Dan Ruan
JFJie Fu
Jie Fu
YGYu Gao
Yu Gao
GCGeraldine Chee
Geraldine Chee
JLJohn H Lewis
John H Lewis
To objectively compare the suitability of MRI pulse sequences and commercially available fiducial markers (FMs) for MRI-only prostate radiotherapy simulation. Most FMs appear as small signal voids in MRI images making them difficult to differentiate from tissue heterogeneities such as calcifications. In this study we use quantitative metrics to objectively evaluate the visibility of FMs in 27 patients and an anthropomorphic phantom with a variety of standard clinical MRI pulse sequences and commercially available FMs. FM visibility was quantified using the local contrast-to-noise-ratio (lCNR), the difference between the 80th and 20th percentile iso-intensity FM volumes ( V fall ) and the largest iso-intensity volume that can be distinguished from background: apparent-marker-volume (AMV). A larger lCNR and AMV, and smaller V fall represents a more easily identifiable FM. The number of non-marker objects visualized by each pulse sequence was calculated using FM-derived template-matching. The FM-based target-registration-error (TRE) between each MRI and the planning-CT image was calculated. Fiducial marker visibility was rated by two medical physicists with over three years of experience examining MRI-only prostate simulation images. The rater’s classification accuracy was quantified using the F 1 score, which is the harmonic mean of the rater’s precision and recall. These quantitative metrics and human observer ratings were used to evaluate FM identifiability in images from nine subtypes of T 1 -weighted, T 2 -weighted and gradient echo (GRE) pulse sequences in a 27-patient study. A phantom study was conducted to quantify the visibility of 8 commercially available FMs. In the patient study, the largest mean lCNR and AMV and, smallest normalized V fall were produced by the 3.0 T multiple-echo GRE pulse sequence ( T 1 -VIBE, 2° flip angle, 1.23 ms and 2.45 ms echo-times). This pulse sequence produced no false marker detections and TREs less than 2 mm in the left–right, anterior–posterior and cranial–caudal directions, respectively. Human observers rated the 1.23 ms echo-time GRE images with the best average marker visibility score of 100% and an F 1 score of 1. In the phantom study, the Gold-Anchor GA-200X-20-B (deployed in a folded configuration) produced the largest sequence averaged lCNR and AMV measurements at 16.1 and 16.7 mm 3 , respectively. Using quantitative visibility and distinguishability metrics and human observer ratings, the patient study demonstrated that multiple-echo GRE images produced the best gold FM visibility and distinguishability. The phantom study demonstrated that markers manufactured from platinum or iron-doped gold quantitatively produced superior visibility compared to their pure gold counterparts.

13 May 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
BLBraian Adair Maldonado Luna
Braian Adair Maldonado Luna
GPGerardo Uriel Rojas Perez
Gerardo Uriel Rojas Perez
RPRené Eduardo Rodríguez Pérez
René Eduardo Rodríguez Pérez
BABenito de Celis Alonso
Benito de Celis Alonso
KSKamal Singhrao
Kamal Singhrao
Purpose: Stochastic bowel and rectal gas complicates MRI/CT deformable image registration (DIR) for synthetic CT (sCT) generation, requiring manual corrections. We propose a DIR-free, two-stage deep learning framework to improve intraluminal gas definition in sCT, streamlining MRI-only simulation and enhancing dosimetric reliability. Methods: We developed a two-stage GAN framework for sCT generation. First, a CycleGAN or pix2pix model converted MRIs into segmented map images (SMI); second, a pix2pix conditional GAN generated the final sCT. Ground-truth gas cavities were defined using CNN-based gastrointestinal autosegmentation, manual verification, and a 20% intensity threshold. Trained on a 60-patient dataset, the framework was compared to a single-stage MRI-to-sCT model via Dice-Sørensen coefficient and Mean Absolute Error (MAE). Dosimetric accuracy was assessed by recalculating prostate VMAT plans (36.25 Gy/5 fractions) on synthetic CTs. Results: The gas cavity Dice-Sørensen coefficient for the two-stage method and the single-stage method were 0.63 ± 0.11 and 0.04 ± 0.03 for pix2pix, while for CycleGAN, they were 0.67 ± 0.07 and 0.57 ± 0.11, respectively. The global MAE for the standard single-stage method and the two-stage method for pix2pix were 86±20 HU and 94±20 HU, while for CycleGAN, they were 105±21 HU and 103±22 HU, respectively. Dosimetric analysis demonstrated excellent agreement for the planning target volume (PTV D95%), with mean differences of 0.04 ± 0.08 cGy and −0.89 ± 1.98 cGy for the one-stage and two-stage models, respectively. Both models exhibited negligible deviations across all assessed organ-at-risk (OAR) volumetric metrics, including D0.1cc, D1cc, and D15cc. Conclusions: The two-stage framework significantly enhances sCT intraluminal gas accuracy, improving cavity definition nearly threefold over single-stage models while maintaining tissue fidelity. This overcomes a major MRI-only simulation bottleneck. Future studies will prospectively evaluate its clinical impact on online adaptive radiotherapy.

5 August 2026 in Radiology Advances
Verified
Journal Article
Open access
XMXin Miao
Xin Miao
NLNam G Lee
Nam G Lee
HNHaiThuy N Nguyen
HaiThuy N Nguyen
JUJesus Uribe
Jesus Uribe
EDEamon K Doyle
Eamon K Doyle
KNKrishna S Nayak
Krishna S Nayak
Background: Pediatric pulmonary diseases are commonly evaluated with imaging that either involves ionizing radiation or that lacks regional functional information. Purpose: To evaluate the feasibility of simultaneous structural and functional lung assessment in pediatric participants without radiation, contrast administration, or breath-holding. Materials and Methods: This retrospective study analyzed pediatric patients with pulmonary disease and healthy participants, who were recruited from August 2023 to December 2025 via convenience sampling and underwent awake lung MRI on wide-bore 0.55-T scanners. A prototype balanced steady-state free-precession sequence with a half-radial dual-echo readout (bSTAR) was acquired with free breathing. Respiratory-resolved 3-dimensional images were reconstructed for structural evaluation and quantitative ventilation mapping. Two pediatric radiologists independently scored image quality (robustness to motion and streak artifacts, and parenchymal signal) and the anatomic visibility of the airways and vessels using 4-point Likert scales. Interreader agreement of structural findings was evaluated using Cohen’s κ. Ventilation defect percentage measured by bSTAR was compared with 2-dimensional phase-resolved functional lung (PREFUL) MRI using Pearson correlation and Bland–Altman analysis. Results: Fourteen participants (median [range] age, 11 [6-16] years; 8 females) were scanned. Image quality scores ranged from 3.0 to 3.8 on Likert scales. All cases were diagnostically acceptable (artifact robustness scores ≥2), with consistent visualization of segmental airway walls and subsegmental vasculature. Structural findings, including consolidation, mucus plugging, ground-glass opacity, air trapping, bronchiectasis, and mosaic hypointensity, showed substantial interreader agreement (κ = 0.6-0.8). Ventilation defects measured by bSTAR correlated strongly with PREFUL (r = 0.81, P < .001), with 95% limits of agreement of −18% to 23%. Conclusion: Simultaneous structural-functional lung imaging in a single free-breathing acquisition was feasible in this cohort of older awake pediatric participants using 0.55-T MRI, with structural images suitable for evaluating major pulmonary findings and quantitative ventilation metrics correlating strongly with PREFUL.