Shihong Chen

Shihong Chen

Auto-generated profile, based on publicly available information

Shihong Chen

Southwest University

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XLXiaofang Liu
Xiaofang Liu
LZLing Zhang
Ling Zhang
SWShaping Wei
Shaping Wei
SCShihong Chen
Shihong Chen
XOXin Ou
Xin Ou
QLQiyi Lu
Qiyi Lu

1 April 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XFXiaomin Fu
Xiaomin Fu
XTXingrong Tan
Xingrong Tan
RYRuo Yuan
Ruo Yuan
SCShihong Chen
Shihong Chen

1 September 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
JZJinwen Zhao
Jinwen Zhao
YHYing He
Ying He
KTKe Jun Tan
Ke Jun Tan
JYJun Yang
Jun Yang
SCShihong Chen
Shihong Chen
RYRuo Yuan
Ruo Yuan

9 July 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JLJin-Hua Luo
Jin-Hua Luo
QLQin Li
Qin Li
SCShi-Hong Chen
Shi-Hong Chen
RYRuo Yuan
Ruo Yuan

14 October 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
QLQiyi Lu
Qiyi Lu
JZJuanjuan Zhang
Juanjuan Zhang
XLXiaofang Liu
Xiaofang Liu
YWYuanya Wu
Yuanya Wu
RYRuo Yuan
Ruo Yuan
SCShihong Chen
Shihong Chen
In this work, an enhanced electrochemiluminescence (ECL) sensor based on gold nanoflower@graphitic carbon nitride polymer nanosheet–polyaniline hybrids (AuNF@g-C3N4–PANI) was prepared for the detection of dapamine (DA). First, the bulk g-C3N4 was prepared through polymerizing melamine under 600 °C. And then the g-C3N4 nanosheet was obtained by ultrasonication-assisted liquid exfoliation of bulk g-C3N4. Finally, polyaniline (PANI) and gold nanoflowers (AuNFs) were successively formed on the g-C3N4 nanosheet through an in situ synthesis method. The resulting AuNF@g-C3N4–PANI hybrids were modified onto the surface of glassy carbon electrode to achieve a sensor (AuNF@g-C3N4–PANI/GCE) for detecting dopamine. Under the optimal conditions, the ECL signal increased linearly with the concentration of dopamine. The linear range of 5.0 × 10−9 to 1.6 × 10−6 M was obtained, while the detection limit was 1.7 × 10−9 M. The prepared sensor exhibited a low detection limit and high sensitivity for the determination of dopamine. The combination of g-C3N4 nanosheet, PANI and AuNF would provide a new opportunity for the ECL sensor.

1 October 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
QLQiyi Lu
Qiyi Lu
HHHongxiang Hu
Hongxiang Hu
YWYuanya Wu
Yuanya Wu
SCShihong Chen
Shihong Chen
DYDehua Yuan
Dehua Yuan
RYRuo Yuan
Ruo Yuan