The most outstanding feature of scanning force microscopy (SFM) is its capability to detect various different short and long range interactions. In particular, magnetic force microscopy (MFM) is used to characterize the domain configuration in ferromagnetic materials such as thin films grown by physical techniques or ferromagnetic nanostructures. It is a usual procedure to separate the topography and the magnetic signal by scanning at a lift distance of 25–50 nm such that the long range tip–sample interactions dominate. Nowadays, MFM is becoming a valuable technique to detect weak magnetic fields arising from low dimensional complex systems such as organic nanomagnets, superparamagnetic nanoparticles, carbon-based materials, etc. In all these cases, the magnetic nanocomponents and the substrate supporting them present quite different electronic behavior, i.e., they exhibit large surface potential differences causing heterogeneous electrostatic interaction between the tip and the sample that could be interpreted as a magnetic interaction. To distinguish clearly the origin of the tip–sample forces we propose to use a combination of Kelvin probe force microscopy (KPFM) and MFM. The KPFM technique allows us to compensate in real time the electrostatic forces between the tip and the sample by minimizing the electrostatic contribution to the frequency shift signal. This is a great challenge in samples with low magnetic moment. In this work we studied an array of Co nanostructures that exhibit high electrostatic interaction with the MFM tip. Thanks to the use of the KPFM/MFM system we were able to separate the electric and magnetic interactions between the tip and the sample.
High-resolution magnetic imaging is of utmost importance to understand magnetism at the nanoscale. In the present work, we use a magnetic force microscope (MFM) operating under in-plane magnetic field in order to observe with high accuracy the domain configuration changes in Co nanowires as a function of the externally applied magnetic field. The main result is the quantitative evaluation of the coercive field of the individual nanostructures. Such characterization is performed by using an MFM-based technique in which a map of the magnetic signal is obtained as a function of both the lateral displacement and the magnetic field.
Strain-induced self-assembled nanoislands of lateral size 50−150 nm and height 10−40 nm have been grown on yttria-stabilized zirconia (001)-substrates from ultradiluted chemical solutions based on metal propionates. The nanoislands grow highly relaxed withstanding the epitaxial relation and show bulk-like average magnetic properties in terms of Curie temperature and saturation magnetization. The interplay of the magnetocrystalline and shape anisotropy within the nanoisland ensemble results in an in-plane magnetic anisotropy with a magnetocrystalline constant and in-plane easy axis along the direction as measured, for the first time, through ferromagnetic resonance experiments. Magnetic force microscopy studies reveal the correlation between nanoisland size and its magnetic domain structure in agreement with micromagnetic simulations. In particular, we have established the required geometric conditions for single domain, multidomain, and vortex configurations.
Magnetic domain configurations in two samples containing small aggregates of Fe 3−x O 4 nanoparticles of about 11 and 49 nm in size, respectively, were characterized by magnetic force microscopy (MFM).
This work reports on the experimental characterization of the magnetic domain configurations in cubic, isolated Fe 3−x O 4 nanoparticles with a lateral size of 25–30 nm.
We have performed sensitivity mapping of graphene Hall devices with the width of 0.6–15 μm operating in the diffusive regime under non-uniform, local magnetic and electric fields induced by a scanning metallic magnetic probe. The transverse voltage was recorded, while tuning the magnitude and orientation of the bias current, the probe-sample distance, and orientation of the probe magnetization. A strong two-fold symmetry pattern has been observed, as a consequence of capacitive coupling between the probe and the sample. The effect is particularly pronounced in small devices (<1 μm), where the dominating electric field contribution significantly lowers the effective area of the magnetic sensor. We show that implementation of the Kelvin probe feedback loop in the standard scanning gate microscopy setup drastically reduces parasitic electric field effects and improves magnetic sensitivity.