Susumu Wada

Susumu Wada

Auto-generated profile, based on publicly available information

Susumu Wada

Laboratory for Joint Tissue Repair and Regeneration, Orthopaedic Soft Tissue Research Program, Hospital for Special Surgery, New York, NY, USA

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2016 in Advanced Materials
Verified
Journal Article
Open access
PDF file
TNTakayuki Nonoyama
Takayuki Nonoyama
SWSusumu Wada
Susumu Wada
RKRyuji Kiyama
Ryuji Kiyama
NKNobuto Kitamura
Nobuto Kitamura
MMMd.TAriful Islam Mredha
Md.TAriful Islam Mredha
JGJianping Gong
Jianping Gong
Implanting hydroxyapatite-mineralized tough hydrogel into osteochondral defects of rabbits, osteogenesis spontaneously penetrates into the gel matrix owing to the semi-permeablility of the hydrogel. The gradient layer (around 40 μm thick) contributes quite strong bonding of the gel to bone. This is the first success in realizing the robust osteointegration of tough hydrogels, and the method is simple and feasible for practical use.

1 July 2017 in Biomaterials
Verified
Journal Article
Closed access
TMTariful Islam Mredha
Tariful Islam Mredha
NKNobuto Kitamura
Nobuto Kitamura
TNTakayuki Nonoyama
Takayuki Nonoyama
SWSusumu Wada
Susumu Wada
KGKeiko Goto
Keiko Goto
JGJianping Gong
Jianping Gong

6 August 2019 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
YNYusuke Nakagawa
Yusuke Nakagawa
LFLisa A. Fortier
Lisa A. Fortier
JMJeremy J. Mao
Jeremy J. Mao
CLChang Hun Lee
Chang Hun Lee
MGMargaret B. Goodale
Margaret B. Goodale
SRScott A. Rodeo
Scott A. Rodeo
Background: Artificial meniscal scaffolds are being developed to prevent development of osteoarthritis after meniscectomy. Previously, it was reported that 3-dimensional (3D) anatomic scaffolds loaded with connective tissue growth factor (CTGF) and transforming growth factor β3 (TGF-β3) achieved meniscal regeneration in an ovine model. This was a relatively short-term study (3 months postoperative), and outcome analyses did not include magnetic resonance imaging (MRI). Purpose: To evaluate long-term outcome of meniscal replacement with growth factor–laden poly-ε-caprolactone (PCL) scaffolds. Study Design: Controlled laboratory study. Methods: Anatomically shaped ovine meniscal scaffolds were fabricated from PCL with a 3D printer based on MRI data. Skeletally mature sheep (N = 34) were randomly allocated to 3 groups: scaffold without growth factor (0-µg group), scaffold with CTGF microspheres (µS) (5 µg) + TGF-β3 µS (5 µg) (5-µg group), and scaffold with CTGF µS (10 µg) + TGF-β3 µS (10 µg) (10-µg group). Unilateral medial meniscal replacement was performed. Animals were euthanized at 6 or 12 months. Regenerated meniscus, articular cartilage status, and synovial reaction were evaluated quantitatively with gross inspection, histology, and MRI. Kruskal-Wallis and Dunn tests were used to compare the 3 groups. Results: Remnants of the PCL scaffold were evident in the 6-month specimens and were decreased but still present at 12 months in most animals. There were no significant differences among groups in gross inspection, histology, or MRI for either meniscal regeneration or articular cartilage protection. All experimental groups exhibited articular cartilage degeneration as compared with control (nonoperated). In terms of synovitis, there were no clear differences among groups, suggesting that growth factors did not increase inflammation and fibrosis. MRI revealed that meniscal extrusion was observed in most animals (82.7%). Conclusion: Previously, the combination of CTGF and TGF-β3 was shown to stimulate mesenchymal stem cells into a fibrochondrocyte lineage. CTGF and TGF-β3 did not aggravate synovitis, suggesting no adverse response to the combination of 3D-printed PCL scaffold combined with CTGF and TGF-β3. Further work will be required to improve scaffold fixation to avoid meniscal extrusion. Clinical Relevance: A significant advantage of this technique is the ability to print custom-fit scaffolds from MRI-generated templates. In addition, average-size menisci could be printed and available for off-the-shelf applications. Based on the 1-year duration of the study, the approach appears to be promising for meniscal regeneration in humans.

1 October 2016 in Acta Biomaterialia
Verified
Journal Article
Closed access
SWSusumu Wada
Susumu Wada
NKNobuto Kitamura
Nobuto Kitamura
TNTakayuki Nonoyama
Takayuki Nonoyama
RKRyuji Kiyama
Ryuji Kiyama
TKTakayuki Kurokawa
Takayuki Kurokawa
KYKazunori Yasuda
Kazunori Yasuda

20 July 2018 in Arthroscopy
Verified
Journal Article
Closed access
DWDean Wang
Dean Wang
HTHongbo Tan
Hongbo Tan
ALAmir H. Lebaschi
Amir H. Lebaschi
YNYusuke Nakagawa
Yusuke Nakagawa
SWSusumu Wada
Susumu Wada
SRScott A. Rodeo
Scott A. Rodeo

15 September 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
XZXueying Zhang
Xueying Zhang
SWSusumu Wada
Susumu Wada
YZYing Zhang
Ying Zhang
DCDaoyun Chen
Daoyun Chen
XDXiang-Hua Deng
Xiang-Hua Deng
SRScott A. Rodeo
Scott A. Rodeo
Background: The purpose of this study was to assess mitochondrial dysfunction in a murine model of supraspinatus tendinopathy. Methods: Eighty-four mice (168 limbs) were included in the study. Supraspinatus tendinopathy was induced by inserting a microsurgical clip in the subacromial space of 63 mice bilaterally (126 limbs). Forty-two of these limbs were harvested at 4 weeks postoperatively, 42 underwent clip removal at 4 weeks after the initial procedure and were harvested at 2 weeks, and 42 underwent clip removal at 4 weeks and were harvested at 4 weeks. Forty-two limbs in the remaining 21 mice did not undergo surgical intervention and were utilized as the control group. Outcomes included biomechanical, histological, gene expression, superoxide dismutase (SOD) activity, and transmission electron microscopy (TEM) analyses. Results: Radiographs confirmed stable clip position in the subacromial space at 4 weeks. Biomechanical testing demonstrated a 60% decrease in failure force of the supraspinatus tendons at 4 weeks compared with the control group. The failure force gradually increased at 2 and 4 weeks after clip removal. Histological analysis demonstrated inflammation surrounding the tendon with higher modified Bonar scores at 4 weeks after clip placement followed by gradual improvement following clip removal. The expression of mitochondrial-related genes was decreased at 4 weeks after clip placement and then significantly increased after clip removal. SOD activity decreased significantly at 4 weeks after clip placement but increased following clip removal. TEM images demonstrated alterations in morphology and the number of mitochondria and cristae at 4 weeks after clip placement with improvement after clip removal. Conclusions: Mitochondrial dysfunction appears to be associated with the development of tendinopathy. Clinical Relevance: Mitochondrial protection may offer a potential strategy for delaying the development of tendinopathy and promoting tendon healing.