3 April 2025 in IEEE Sensors Journal
Presented in this article are experimental results of an investigation on the performance of distributed fiber optic temperature sensors at temperatures up to $800~^{\circ }$ C. The experimental results produced in this work assess the performance of fiber optic temperature sensors for use in instrumenting liquid metal heat pipes. Distributed fiber optic temperature sensors are capable of providing high spatial and temporal resolution temperature measurements across a wide range of operating temperatures and conditions, making them intriguing candidates for many advanced nuclear reactor technologies. Tests were conducted at high temperature on the prolonged survivability, short-term performance, and high-temperature cycling effects of distributed optical fiber temperature sensors. A quartic fit of the spectral shift produced by the fiber sensors was developed to fit with thermocouple (TC) measurements of the experiment and was compared with fits available in literature. An upper limit of $700~^{\circ }$ C was established for the prolonged use of distributed fiber optic sensors. No significant hysteresis effects were observed when the fiber sensors were cycled at high temperatures. Distributed fiber optic temperature sensors were determined to be viable for instrumenting liquid metal heat pipes under limited operational conditions.
24 March 2026 in SSRN Electronic Journal
Liquid metal heat pipes are being evaluated for a variety of space and microreactor applications. The operating envelope of these devices is dominated by the capillary limit, which is determined largely by the capillary radius and permeability of the heat pipe wick structure. To simultaneously enhance both parameters, wrapped mesh screen wicks that leave a gap between the mesh and cladding have been proposed. Little quantification of the effect of the annular gap has been performed, and none using realistic annular geometry. This work used rate-of-rise testing to measure the capillary radius and permeability of rectangular and annular wick samples made from 316 stainless steel 100-mesh screen. The annular samples, around 21 mm in outer diameter, were then measured with cladding that created an annular gap of around 0.63 mm. Two possibilities exist when calculating the capillary radius and permeability from rate-of-rise data with an annular gap: using the bare mesh cross-sectional area and porosity or using the total mesh plus gap area with an averaged porosity. Both methods were evaluated, and a comparison to a simple analytic model suggested that the latter was more representative of the actual phenomena. However, this resulted in only a 1.3 to 1.6-times increase in the wick figure of merit compared to a three-times increase using the former method employed by other researchers. These discrepancies need to be further investigated by comparing the rate-of-rise method with independent measurements of permeability and capillary radius using forced flow and bubble point techniques, respectively.