The advance of micro/nanotechnology in energy-harvesting, micropower, electronic devices, and transducers for automobile and aerospace applications has led to the need for accurate thermomechanical characterization of micro/nano-scale materials to ensure their reliability and performance. This persistent need has driven various efforts to develop innovative experimental techniques that overcome the critical challenges associated with precise mechanical and thermal control of micro/nano-scale specimens during material characterization. Here we review recent progress in the development of thermomechanical testing methods from miniaturized versions of conventional macroscopic test systems to the current state of the art of in situ uniaxial testing capabilities in electron microscopes utilizing either indentation-based microcompression or integrated microsystems. We discuss the major advantages/disadvantages of these methods with respect to specimen size, range of temperature control, ease of experimentation and resolution of the measurements. We also identify key challenges in each method. Finally, we summarize some of the important discoveries that have been made using in situ thermomechanical testing and the exciting research opportunities still to come in micro/nano-scale materials.
A new method of 'directed' self-assembly is demonstrated that has the potential to simply and quickly build nanostructured materials and devices. Called spin-spray layer-by-layer self-assembly (SSLbL), it is a modification of the well-known layer-by-layer method (LbL). Using SSLbL, it is possible to create and stack nanometre-thick, uniform layers containing a wide variety of different polymers, nanoparticles, or colloids in less than 25 s per bilayer, orders of magnitude faster than traditional LbL. This is done by modifying traditional dipping LbL to a system where carefully chosen volumes of polymer or colloidal solutions are sprayed directly on a rotating substrate. SSLbL is also much less wasteful of valuable nanoparticles and polymers than LbL. It is shown that in contrast to less than 1% material usage found in LbL, SSLbL has material usage efficiency up to 50%, and this can be further improved. Another direct result of the spin-spray modification is simple control of the in-plane structure of nanolayered films using masks, which is demonstrated. Such capability opens up the possibility of simply and inexpensively building complete nanocomposite devices with both vertical and lateral organization.
Detection and location of the source of acoustic emission in a thin aluminum panel is demonstrated using a multichannel fiber laser sensor system. Acoustic emission generated by a crack in an aluminum panel used as a test coupon in an accelerated fatigue experiment is detected and the location of the crack identified. Acoustic emission is detected over a bandwidth of around 0.5 MHz from a serially multiplexed array of four laser sensors and compared with measurements taken from four piezo-electric sensors co-located with the fiber laser sensors. The location of the crack is determined by first estimating time difference of arrival of signals at each sensor using a novel algorithm based on the cumulative distribution transform method with hyperbolic positioning. The fiber laser sensor is shown to match the signal-to-noise ratio of the industry standard (Mistras S9225) piezo-electric acoustic emission sensor.
The dynamic response of cells when subjected to mechanical impact has become increasingly relevant for accurate assessment of potential blunt injuries and elucidating underlying injury mechanisms. When exposed to mechanical impact, a biological system such as the human skin, brain, or liver is rapidly accelerated, which could result in blunt injuries. For this reason, an acceleration of greater than > 150 g is the most commonly used criteria for head injury. To understand the main mechanism(s) of blunt injury under such extreme dynamic threats, we have developed an innovative experimental method that applies a well-characterized and -controlled mechanical impact to live cells cultured in a custom-built in vitro setup compatible with live cell microscopy. Our studies using fibroblast cells as a model indicate that input acceleration ( $${a}_{in}$$ ) alone, even when it is much greater than the typical injury criteria, e.g., $${a}_{in}>1{,}000$$ g, does not result in cell damage. On the contrary, we have observed a material-dependent critical pressure value above which a sudden decrease in cell population and cell membrane damage have been observed. We have unambiguously shown that (1) this critical pressure is associated with the onset of cavitation bubbles in a cell culture chamber and (2) the dynamics of cavitation bubbles in the chamber induces localized compressive/tensile pressure cycles, with an amplitude that is considerably greater than the acceleration-induced pressure, to cells. More importantly, the rate of pressure change with time for cavitation-induced pressure is significantly faster (more than ten times) than acceleration-induced pressure. Our in vitro study on the dynamic response of biological systems due to mechanical impact is a crucial step towards understanding potential mechanism(s) of blunt injury and implementing novel therapeutic strategies post-trauma.
The fundamental challenge of nanomanufacturing is to create, control, and place immense quantities of nanoscale objects controllably over large surface areas. Electrospray ionization (ESI) has the potential to address this challenge due to its simplicity, applicability to a broad range of materials, and intrinsic scalability. However, the interactions between electrospray parameters and final deposited morphology are not well understood. Experimental results are combined with physics-based models to explain how observed particle size distributions are caused in the spray by evaporation and Coulomb fission of drops with solute concentration gradients.