Sara Nunes

Sara Nunes

Auto-generated profile, based on publicly available information

Sara Nunes

Anaesthesia Department, Centro Hospitalar do Funchal, Funchal, Madeira, Portugal

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Revista Brasileira de Anestesiologia
Verified
Journal Article
Open access
JNJoana Nunes
Joana Nunes
SNSara Nunes
Sara Nunes
MVMariano Veiga
Mariano Veiga
MCMara Cortez
Mara Cortez
ISIsabel Seifert
Isabel Seifert
There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10mL with Ropivacaine 0.16% plus Sufentanil 10μg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2μg/mL solution as continuous epidural infusion (5mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2μg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10mL/h starting 60min after the initial bolus. Rescue boluses of 5mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. We analyzed 130 pregnants (A=60; B=33; C=37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p=0.83). We found a higher caesarean delivery rate in group A (56.7%; p=0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

3 March 2022 in BMJ Case Reports
Verified
Journal Article
Closed access
PDF file
APAna Isabel Pereira
Ana Isabel Pereira
DFDiana Lastra Fernandes
Diana Lastra Fernandes
AAAna Amorim
Ana Amorim
SNSara Nunes
Sara Nunes
Neuraxial anaesthesia is an essential technique in obstetric anaesthesia practice. Cerebrospinal fluid (CSF) fistula is a rare complication and there is no consensus about its clinical approach. We present a case of a 28-year-old nulliparous woman that developed a cutaneous CSF fistula following combined spinal and epidural block for caesarean delivery. After multidisciplinary discussion it was decided that hydration, absolute bed-rest and compressive dressing with abdominal binder was the best option and the patient fully recovered without any sequelae. Based on literature, symptoms of intracranial hypotension and leakage of clear fluid surrounding the puncture site usually motivate referral to anaesthesia. Management strategies can be both conservative and invasive, including direct suture of the skin puncture site and epidural blood patch. Regarding the anaesthesia practice on this topic, most of the available evidence is based on case reports, rendering the decision-making process challenging.