3 February 2021 in Brazilian Journal of Anesthesiology (English Edition)
Laryngeal mask airways are increasingly used as supraglottic devices during general anesthesia. Ultrasonography can provide a dynamic image simultaneous to placing the supraglottic airway device. In the current study, the incidence of suboptimal laryngeal mask airway position and replacement in children was evaluated using simultaneous ultrasonographic imaging. A prospective observational study was conducted on 82 patients aged 3–15 years with American Society of Anesthesiologists (ASA) physical status I or II. Patients under general anesthesia and with airway provided by a laryngeal mask airway were included. The position of the laryngeal mask airway was evaluated by ultrasonography on two planes. According to our scoring system, Grade I and Grade II were determined to indicate acceptable placement, while Grade III was determined to indicate unacceptable placement. Suboptimal laryngeal mask airway placement rates and the requirement of replacement were determined. Laryngeal mask airway placement optimized by ultrasonography was evaluated with both leak tests and a fiberoptic laryngoscope. The average age of the patients was 6.27 ± 4.66 years. After evaluation with ultrasonography, 65 (79.3%) of the laryngeal mask airways were found to be optimally positioned, while the position of 13 (15.9%) had to be corrected, and 4 (4.9%) had to be replaced. There was a moderate positive correlation between the ultrasonographic evaluation and leak test evaluation (p < 0.001; r = 0.628). Relocation of the laryngeal mask airway was determined to be an independent risk factor affecting the development of complications (OR = 2.961; p = 0.046; 95% Cl 2.850–30.745). The use of ultrasonography to verify and relocate laryngeal mask airway placement is noninvasive and effective.
19 May 2020 in Istanbul Medical Journal
1 April 2026 in Journal of Surgery and Medicine
Background/Aim: This study aimed to evaluate a software prototype developed for the digitalization of intraoperative hemodynamic data recording and to examine healthcare professionals’ acceptance of this system within the framework of the Technology Acceptance Model. Methods: This single-center, cross-sectional, descriptive study was conducted in the operating room of a university hospital between January 1, 2025, and December 31, 2025. A total of 75 healthcare professionals actively involved in intraoperative patient monitoring were included. Data were collected using a Participant Information Form and the 28-item Technology Acceptance Model Scale. Statistical analyses included descriptive statistics, independent samples t-test, one-way analysis of variance, Pearson correlation analysis, and multiple linear regression analysis. Results: Participants had high perceived usefulness and perceived ease of use scores, with mean (SD) values of 4.31 (0.56) and 4.23 (0.60), respectively. Age was negatively and significantly correlated with perceived usefulness (r=-0.348, P=0.002), indicating that perceived usefulness decreased with increasing age. Professional experience significantly differed according to perceived ease of use (P=0.042). No significant relationship was found between perceived ease of use and perceived usefulness (r=0.030, P=0.797). Multiple linear regression analysis showed that age was an independent significant predictor of perceived usefulness (β=-0.025, 95% CI: -0.040 to -0.009, P=0.002). Conclusion: Digital intraoperative hemodynamic data recording was highly accepted by healthcare professionals. The finding that age was associated with technology acceptance suggests that generational differences should be considered during digital transformation. Automated recording systems may reduce workload and improve patient safety; however, organizational support and adequate technical infrastructure are critical for widespread implementation.