Lead sulfide (PbS) quantum dots (QDs) have great potential in optoelectronic applications because of their desirable characteristics as a light absorber for near-infrared (NIR) photodetection. However, most PbS-based NIR photodetectors are two-terminal devices, which require an integrated pixel circuit to be practical photosensors. Here we report on PbS QD/indium gallium zinc oxide (InGaZnO, IGZO) metal oxide semiconductor hybrid phototransistors with a photodetection capability between 700 and 1400 nm, a range that neither conventional Si nor InGaAs photodetectors can cover. The new hybrid phototransistor exhibits excellent photoresponsivity of over 106 A W−1 and a specific detectivity in the order of 1013 Jones for NIR (1000 nm) light. Furthermore, we demonstrate an NIR (1300 nm) imager using photogating inverter pixels based on PbS/IGZO phototransistors at an imaging frequency of 1 Hz with a high output voltage photogain of ~4.9 V (~99%). To the best of our knowledge, this report demonstrates the first QD/metal oxide hybrid phototransistor-based flat panel NIR imager. Our hybrid approach using QD/metal oxide paves the way for the development of gate-tunable and highly sensitive flat panel NIR sensors/imagers that can be easily integrated.
Cost-effective and high-performance H2S sensors are required for human health and environmental monitoring. 2D transition-metal carbides and nitrides (MXenes) are appealing candidates for gas sensing due to good conductivity and abundant surface functional groups but have been studied primarily for detecting NH3 and VOCs, with generally positive responses that are not highly selective to the target gases. Here, we report on a negative response of pristine Ti3C2Tx thin films for H2S gas sensing (in contrast to the other tested gases) and further optimization of the sensor performance using a composite of Ti3C2Tx flakes and conjugated polymers (poly[3,6-diamino-10-methylacridinium chloride-co-3,6-diaminoacridine-squaraine], PDS-Cl) with polar charged nitrogen. The composite, preserving the high selectivity of pristine Ti3C2Tx, exhibits an H2S sensing response of 2% at 5 ppm (a thirtyfold sensing enhancement) and a low limit of detection of 500 ppb. In addition, our density functional theory calculations indicate that the mixture of MXene surface functional groups needs to be taken into account to describe the sensing mechanism and the selectivity of the sensor in agreement with the experimental results. Thus, this report extends the application range of MXene-based composites to H2S sensors and deepens the understanding of their gas sensing mechanisms.