30 May 2020 in Journal of Renal Injury Prevention
Introduction: Noise is defined as an interfering and unwanted sound. Exposure to noise induces health problems in humans and animals. Cigarette smoke (CS) has also been known to cause serious problems in health hazard and leads to many kinds of diseases. However, the effects of these agents on the kidney are poorly studied. Objectives: The current study purposes to investigate the impact of noise and/or CS on rat’s kidney Materials and Methods: Four groups of six Wistar adult male rats were used. They randomly were divided into four groups of rats. The first group was used as control. The second group was exposed to noise. The third group was exposed to cigarette smoking and the fourth group was exposed to both noise and CS. The experiments were repeated for two weeks (five days per week). Twenty-four hours after last exposure, the animals were killed by sodium pentobarbital overdose. Renal function was evaluated by the determination of blood urea nitrogen (BUN) and creatinine levels. Oxidative stress was estimated by glutathione (GSH) and malondialdehyde (MDA) assays. Results: The concentrations of BUN and creatinine remarkably raised (P ≤ 0.05) in all groups compared to those in control rats. However, elevations of the biochemical tests were more predominant in rats exposed to combined noise and CS. Elevation of MDA was observed in all exposed rats, while it was more pronounced in the animals exposed to the combined noise and CS when compared to control, CS or noise exposure rats alone. The level of GSH decreased in all exposed groups. It was more obvious in rats exposed to the combined noise and CS when compared to those of control and exposure rats to noise or CS separately. Conclusion: Exposure to noise or CS impaired renal function. Generation of oxidative stress at least in part may be responsible for their nephrotoxicity. Our findings demonstrated CS aggravated noise induced impairment of renal function.
22 November 2020 in Jundishapur Journal of Health Sciences
Background: Having enough ability to perform delegated tasks has a crucial role in preventing job-related accidents and medical errors. Excessive workload, particularly multitasking, causes increased physical stress and job dissatisfaction. Pre-hospital emergency technicians play a crucial role in saving patients' lives, therefore assessing their mental workload and job satisfaction is highly important. Objectives: The current study aimed to investigate the mental workload of pre-hospital emergency technicians working in hospitals in the city of Ahvaz and its association with job satisfaction. Methods: In this study, 252 pre-hospital emergency technicians were studied. The National Aeronautics and Space Administration-Task Load Index (NASA-TLX) was used to assess the mental workload. The Job Descriptive Index (JDI) questionnaire was used to collect information regarding job satisfaction. Data were analyzed using descriptive statistics and ANOVA and chi-square tests. Analyses were performed using SPSS version 22.0. Results: Participants had a moderate level of workload (mean score: 5296). The highest and lowest scores were related to mental demand (69.96 ± 19) and physical demand (32.35 ± 14.3), respectively. Also, participants had a moderate level of job satisfaction, and there was a significant association between job satisfaction and mental demand and frustration (P < 0.05). Conclusions: This study demonstrated an association between job satisfaction and mental demand and frustration in pre-hospital emergency technicians. Therefore, developing appropriate strategies is necessary.
8 December 2024 in Environmental Health Engineering and Management
Background: With the growth of industries and advancing civilization, controlling air pollution from both human and natural sources has become a major concern. Styrene, a volatile organic compound (VOC), is recognized as a hazardous and toxic atmospheric contaminant. Methods: In this study, the removal of Styrene vapors using ZnO and TiO2 nanoparticles coated on activated carbon (AC) was investigated and the styrene removal capacity of AC-ZnO and AC-TiO2 catalysts was compared. The coated adsorbents were characterized using a field emission scanning electron microscope (FESEM), X-ray diffraction patterns (XRD), and the Brunauer–Emmett–Teller (BET) method. All laboratory-scale experiments were conducted at ambient temperatures. Styrene concentrations of 50, 100, and 300 ppm were tested at an input flow rate of 0.03, and 0.06 m3 /h. Results: The AC-TiO2 catalyst had a styrene removal efficiency (RE) of 81%, as compared to 74% efficiency for the AC-ZnO catalyst, this is at a flow rate of 0.06 m3 /h and a concentration of 50 ppm. The results indicated that increasing styrene concentrations reduced breakthrough time but increased adsorption capacity. Also, by increasing the inflow rate, the adsorption capacity decreased. At all concentrations and flow rates, the adsorption capacity of the AC-TiO2 catalyst was higher than the AC-ZnO catalyst. Conclusion: According to the results, it can be concluded that the AC-TiO2 catalyst is more effective in the removal of Styrene vapor from the air as compared to the AC-ZnO catalyst.